Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PD-65A is the CH1: 5V / CH2: 12V output model of this series: rated current CH1: 5.5A / CH2: 2.8A, rated power 61.1W, typical efficiency 78%.
Features
- Universal AC input / Full range
- Low leakage current<0.5mA
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- 100% full load burn-in test
- Fixed switching frequency at 65KHz
- 2 years warranty
Specifications
OUTPUT
- OUTPUT NUMBER
- CH1 / CH2
- DC VOLTAGE
- CH1: 5V / CH2: 12V
- RATED CURRENT
- CH1: 5.5A / CH2: 2.8A
- CURRENT RANGE
- CH1: 0.4 ~ 7A / CH2: 0.2 ~ 3.2A
- RATED POWER
- 61.1W
- OUTPUT POWER (max.)
- Rated output power for convection; 72W with 18CFM min. Forced air
- RIPPLE & NOISE (max.)Note.2
- CH1: 50mVp-p / CH2: 120mVp-p
- VOLTAGE ADJ. RANGE
- CH1:4.75 ~ 5.5V
- VOLTAGE TOLERANCENote.3
- CH1: ±4.0% / CH2: ±7.0%
- LINE REGULATION
- CH1: ±1.0% / CH2: ±2.0%
- LOAD REGULATION
- CH1: ±3.0% / CH2: ±4.0%
- SETUP, RISE TIME
- 800ms, 20ms at full load
- HOLD UP TIME (Typ.)
- 60ms at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC 127 ~370VDC
- FREQUENCY RANGE
- 47 ~ 440Hz
- EFFICIENCY(Typ.)
- 78%
- AC CURRENT (Typ.)
- 1.5A/115VAC 0.9A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 20A/115VAC 40A/230VAC
- LEAKAGE CURRENT
- <0.75mA
PROTECTION
- OVERLOAD
- 73 ~ 105W rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed.
- OVER VOLTAGE
- CH1: 5.75 ~ 6.75VDC on CH1 Protection type : Hiccup mode, recovers automatically after fault condition is removed.
ENVIRONMENT
- WORKING TEMP.
- -10 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.04%/℃ (0 ~ 50℃) on +5V output
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 3814.3K hrs min. Telcordia SR-332 (Bellcore) ; 498.8K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 127*76*42mm (L*W*H)
- PACKING
- 0.24Kg; 54pcs/15Kg/1.28CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Mounting holes M1 and M2 should be grounded for EMI purposes.
- 6. Heat Sink HS1,HS2 can not be shorted.
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Datasheet1
Certificates9
Test reports1
Catalogues1
FAQ
Can I use the PD-65A for a 5V controller board with 12V auxiliary loads in an industrial cabinet?
Yes, this model is suited to constant-voltage systems that use the 5V and 12V outputs indicated by the model name. It provides 61.1W total power, a 5V output rated at 5.5A, and accepts 90-264VAC input, which fits small industrial control or embedded assemblies that need those rails.
Is the PD-65A a good fit for embedded test fixtures or automation jigs that need stable 5V power?
It can be a fit where the main requirement is regulated 5V power for embedded electronics, with 61.1W total available and 5.5A on the 5V output. Because it is a constant-voltage supply with 90-264VAC input, it suits bench or factory test equipment designed around those limits.
Can I use the PD-65A in a small PLC or relay control panel that mixes low-voltage logic and support circuits?
Yes, for compact control panels that need a constant-voltage supply and stay within 61.1W total load. The 5V output is rated at 5.5A, and the model name identifies a 12V rail as well, so it is better aligned to mixed-voltage control hardware than a single-output-only unit.
Is the PD-65A suitable for outdoor or harsh-environment use?
The supplied specs do not list an IP rating, so outdoor exposure is not established from this data. Its operating temperature range is -10°C to +60°C, so it is better suited to protected indoor equipment or an enclosure that keeps the unit within that range.
How does the PD-65A compare with other PD series models?
On the PD-65 series sheet, the PD-65A sits alongside the PD-65B. The PD-65A delivers 61.1W from 5V 5.5A and 12V 2.8A outputs with 78% typical efficiency, while the PD-65B delivers 65.5W from 5V 3.5A and 24V 2A outputs with 81% efficiency. Both share the 90-264VAC input and 127*76*42mm size.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other PD Series Models
49 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.