Over 15 years experience of providing support of MEAN WELL Power Supplies
Mean Well RST-7K5-115 High Power AC/DC Power Supply 7475W, 3 Phase Input, 115V Output 65A
Overview
RST-7K5-115 is the model of this series: rated power 7475W, typical efficiency 94%.
RST-7K5-HV is a 7.5KW 3ψinput enclosed type AC/DC power supply. This series operates for the wide range three phase AC input and offers the models with the high voltage DC output(115V/230V/380V) that mostly demanded from the industry. Two types of cooling methods, forced air and water cooling, that can be working at ambient temperature up to 70℃. Moreover, RST-7K5-HV provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, alarm signals.....etc.
Features
- 3ψ 3-wire / △196~305VAC or 3ψ 4-wire / Y 340~530VAC
- High efficiency up to 95%
- Water / forced air cooling selectable
- Output voltage and constant current level programmable
- Wide voltage adjustment range 1~120%
- Active current sharing up to 4 units(28.5KW)
- Built-in remote ON-OFF control / Alarm signal
- Protections: Short circuit / Overload / Over voltage / Over temperature / Fan fail
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE (factory default)
- 115V
- CURRENT (factory default)
- 65A
- CURRENT RANGE
- 0 ~ 65A
- RATED POWER
- 7475W
- FULL POWER VOLTAGE RANGE
- 115 ~ 138V
- RIPPLE & NOISE (max.)Note.2
- 1Vp-p
- VOLTAGE ADJ. RANGE
- 90 ~ 138V Can be adjusted via built-in potentiometer
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 3000ms, 200ms at full load
- HOLD UP TIME (Typ.)
- 16ms 230VAC/400VAC at 75% load 10ms / 230VAC/400VAC at full load
INPUT
- VOLTAGE RANGE
- 3ψ 3W/△196~305VAC or 3ψ 4W/Y 340~530VAC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- ≧0.98/230VAC(400VAC)/≧0.97/277VAC(480VAC) at full load
- EFFICIENCY (Typ.)Note.7
- 94%
- AC CURRENT (Typ.)
- 22.5A/230VAC(3ψ 3-wire /△) 13A/400VAC(3ψ 4-wire / Y)
- INRUSH CURRENT (Typ.)
- 75A/230VAC(3ψ 3-wire /△) 50A/400VAC(3ψ 4-wire / Y)
- LEAKAGE CURRENT
- <3.5mA/Y 530VAC <10mA /△305VAC
PROTECTION
- OVERLOAD
- 100 ~ 107% of rated current Protection type : Constant current limiting. After O/P voltage falls, unit will shut down after 5 sec. re-power on to recover
- OVER VOLTAGE
- 145 ~ 166V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- CURRENT SHARING
- Up to 4 units. Please refer to the Function Manual
- OUTPUT VOLTAGE PROGRAMMABLE
- Adjustment of output voltage is allowable between 1 ~ 120% of nominal output voltage. Please refer to the PV curve Function Manual
- CONSTANT CURRENT LEVEL PROGRAMMABLE
- Adjustment of constant current level is allowable between 20 ~ 100% of rated current. Please refer to the Function Manual
- REMOTE ON-OFF CONTROL
- Please refer to the Function Manual
- ALARM SIGNAL OUTPUT
- AC fail, DC OK, fan fail, OTP. Please refer to the Function Manual
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 45℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGENote.4
- I/P-O/P:4.3KVDC I/P-FG:2.8KVDC O/P-FG:2.8KVDC
- ISOLATION RESISTANCENote.4
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32) / BS EN/EN55011 (CISPR11) Class A Radiated BS EN/EN55032 (CISPR32) / BS EN/EN55011 (CISPR11) Class A Harmonic Current BS EN/EN61000-3-2 Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55024 , BS EN/EN61204-3, BS EN/EN61000-6-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 3 EFT / Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-4-5 Level 4, 4KV/Line-Earth; Level 3, 2KV/Line-Line Conducted BS EN/EN61000-4-6 Level 3 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 234.5K hrs min. Telcordia SR-332 (Bellcore) ; 27.1K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- RST-7K5: 460*211*83.5mm (L*W*H) RST-7K5-L: 460*216*83.5mm (L*W*H)
- PACKING
- RST-7K5: 10.9Kg; 1pcs/11.9Kg/1.3CUFT RST-7K5-L: 10.1Kg; 1pcs/11.1Kg/1.13CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at △230VAC(Y 400VAC) input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance :includes set up tolerance, line regulation and load regulation.
- 4. During withstand voltage and isolation resistance testing, the screw "A" shall be temporarily removed, and shall be installed back after the testing.
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. If use PV signal to adjust Vo, under creatin operation conditions, ripple noise of Vo might go over rating defined in this specification.
- 7. The efficiency is measured at △: 230VAC/Y: 400VAC input. The efficiency level is measured at output voltage 115V(115V model)/230V(230V model)/380V(380V model).
- 8. The power supply is considered a componenr which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 600mm*900mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 10. An unstable O/P voltage is expected in the first 300ms after power on. A minimum load of 5% is suggested if fast load change is required at power on phase.
Technical drawings
Typical applications
- Energy & power system
- U.V or laser diode application
- Electrolysis system
- Factory control or automation apparatus
- Burn-in facility
- RF application
- EV charging station
Downloads
Datasheet1
FAQ
What type of applications is the Mean Well RST-7K5-115 designed for?
The RST-7K5-115 is a high power enclosed AC/DC power supply intended for demanding industrial and commercial systems that need substantial 115V DC output. With a 7475W power rating and 65A rated current, it is suited to applications where high continuous output and 3-phase input support are important purchasing factors.
What are the key output specifications of the RST-7K5-115?
This model provides a nominal 115V output and is rated for 65A, for a total power rating of 7475W. It also features a wide voltage adjustment range of 1 to 120% and programmable output voltage and constant current level.
Does the RST-7K5-115 support high efficiency operation?
Yes. Mean Well specifies typical efficiency of 94% for the RST-7K5-115, which is a strong performance level for a power supply in this class. High efficiency can help reduce wasted energy and support lower thermal burden in high power systems.
What input power configuration does the RST-7K5-115 require?
The RST-7K5-115 is designed for 3-phase AC input. The listed input range is 3-phase 3-wire / delta 196 to 305VAC or 3-phase 4-wire / Y 340 to 530VAC, making it a fit for facilities using industrial-grade 3-phase power.
Can the RST-7K5-115 be used in higher power parallel systems?
Yes. This model supports active current sharing for up to 4 units, allowing system designers to scale output capacity up to 28.5KW. That makes it relevant for higher-demand applications where modular high power expansion is a requirement.
What operating environment and protection features does the RST-7K5-115 offer?
The RST-7K5-115 has an operating temperature range of -30°C to 70°C, supporting use in a wide range of industrial environments. It also includes protection functions for short circuit, overload, over voltage, over temperature, and fan fail, along with selectable water or forced-air cooling.
What warranty comes with the Mean Well RST-7K5-115?
Mean Well lists this model with a 5-year warranty. For B2B buyers evaluating lifecycle cost and long-term support, that warranty period is an important part of the product's value proposition.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other RST-7K5 Models
5 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.