Overview
RS-100-24 is the 24V output model of this series: rated current 4.5A, rated power 108W, typical efficiency 84%.
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105℃ long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70℃
- Withstand 5G vibration test
- High efficiency, long life and high reliability
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 4.5A
- CURRENT RANGE
- 0 ~ 4.5A
- RATED POWER
- 108W
- RIPPLE & NOISE (max.)Note.2
- 120mVp-p
- VOLTAGE ADJ. RANGE
- 22.8 ~ 26.4V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATIONNote.4
- ±0.5%
- LOAD REGULATIONNote.5
- ±0.5%
- SETUP, RISE TIME
- 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 95ms/230VAC 17ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 84%
- AC CURRENT (Typ.)
- 2.5A/115VAC 1.5A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 40A/230VAC
- LEAKAGE CURRENT
- <2mA / 240VAC
PROTECTION
- OVERLOAD
- 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 6)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, AS/NZS 62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 3196.6K hrs min. Telcordia SR-332 (Bellcore) ; 526.7K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 159*97*38mm (L*W*H)
- PACKING
- 0.6Kg; 24pcs/15.4Kg/0.83CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Line regulation is measured from low line to high line at rated load.
- 5. Load regulation is measured from 0% to 100% rated load.
- 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the RS-100-24 for a 24V PLC, sensor bank, or industrial control load?
Yes, this is a constant-voltage 24V model rated for 4.5A and 108W. It fits enclosed industrial control applications that require a 24V DC rail within those limits.
Is the RS-100-24 appropriate for factory automation equipment that runs on 24V DC?
It is well aligned with automation equipment that uses a 24V constant-voltage bus and draws no more than 4.5A or 108W. The listed certifications include UL, TUV, AS/NZS, and EAC, which can be relevant in industrial equipment selection.
Can this model power 24V industrial networking or embedded devices in a cabinet?
It can support enclosed IT, embedded, or communication devices designed for 24V DC, provided the total load stays within 4.5A. The miniature housing size of 159.0 × 97.0 × 38.0 mm also suits compact cabinet layouts.
Is the RS-100-24 suitable for outdoor installations?
The operating temperature range is listed as -25°C to +70°C, but the provided specs do not include an IP rating. Without a stated ingress-protection rating, the listed data supports use in protected indoor enclosures rather than exposed outdoor mounting.
How does the RS-100-24 compare with the other RS-100 outputs?
In the RS-100 family shown here, RS-100-3.3 is 66W at 3.3V 20A, RS-100-5 is 80W at 5V 16A, RS-100-12 is 102W at 12V 8.5A, RS-100-15 is 105W at 15V 7A, RS-100-24 is 108W at 24V 4.5A, and RS-100-48 is 110.4W at 48V 2.3A. RS-100-12-OB is listed as well, but its output specs are not included in the provided data.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other RS-100 Models
1 other model| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well RS-100-3.3 Power Supply 100W 3.3V 20A | 66W | 3.3V | 20A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.