Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
GST90A48-P1M is the 48V output model of this series: rated current 1.87A, typical efficiency 91%.
GST90A is a highly reliable, 90W desktop style single-output green adaptor series. This product is a classⅠ power unit (with FG), equipped with a standard IEC320-C14 AC inlet and adopting the input range from 90VAC to 264VAC. The entire series supplies different models with output voltages ranging between 12VDC and 48VDC that can satisfy the demands for various types of consumer electronic devices. With the efficiency up to 91% and the extremely low no-load power consumption below 0.15W,GST90A is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS,Korea K-MEPS,EU ErP and Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case. GST90A is certified for the international safety regulations.
Features
- Global certificates
- Universal AC input / Full range
- 3 pole AC inlet IEC320-C14,ClassⅠpower unit
- Built-in active PFC function
- No load power consumption< 0.15W
- Energy efficiency Level VI
- Comply with EISA 2007/DoE,NRCan,Korea K-MEPS, AU/NZ MEPS,EU ErP and CoC Version 5
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Fully enclosed plastic case
- -30~+70℃ wide range working temperature
- LED indicator for power on
- Various DC plug quick adapter accessory available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
- 3 years warranty
Specifications
OUTPUT
- SAFETY MODEL NO.
- GST90A48
- DC VOLTAGENote.2
- 48V
- RATED CURRENT
- 1.87A
- CURRENT RANGE
- 0 ~ 1.87A
- RATED POWER (max.)
- 90W
- RIPPLE & NOISE (max.)Note.3
- 200mVp-p
- VOLTAGE TOLERANCENote.4
- ±2.5%
- LINE REGULATIONNote.5
- ±1.0%
- LOAD REGULATION
- ±2.5%
- SETUP, RISE TIMENote.6
- 1000ms, 50ms / 230VAC 1000ms, 50ms / 115VAC at full load
- HOLD UP TIME (Typ.)
- 20ms / 230VAC 20ms / 115VAC at full load
INPUT
- VOLTAGE RANGENote.7
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.91 / 230VAC PF>0.95 / 115VAC at full load
- EFFICIENCY (Typ.)
- 91%
- AC CURRENT (Typ.)
- 1.3A / 115VAC 0.6A / 230VAC
- INRUSH CURRENT (max.)
- Cold start 35 / 115AC 70A / 230VAC
- LEAKAGE CURRENT(max.)
- 1mA / 240VAC
PROTECTION
- OVERLOAD
- 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0~40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote. 8
- UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, CCC GB4943.1, PSE J62368-1,AS/NZS 62368.1 , BIS IS13252, KC K60950-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P: 3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS15936,GB17625.1 EAC TP TC 020,MSIP KN32 Conducted emission Class B BS EN/EN55032(CISPR32),FCC PART 15 / CISPR22 CAN ICES-3(B)/NMB-3(B),CNS15936,GB17625.1 EAC TP TC 020,MSIP KN32 Radiated emission Class B BS EN/EN61000-3-2,GB9254 Harmonic current Class A BS EN/EN61000-3-3 Voltage flicker - EMC IMMUNITY
-
BS EN/EN55035
Parameter Standard Test Level BS EN/EN61000-4-2 ESD Level 4, 15KV air; Level 4, 8KV contact BS EN/EN61000-4-3 RF field susceptibility Level 2, 3V/m BS EN/EN61000-4-4 EFT bursts Level 2, 1KV BS EN/EN61000-4-5 Surge susceptibility Level 3, 1KV/Line-Line , 2KV/Line-FG BS EN/EN61000-4-6 Conducted susceptibility Level 2, 3V BS EN/EN61000-4-8 Magnetic field immunity Level 2, 3A/m BS EN/EN61000-4-11 Voltage dips , interruption >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 2529.4K hrs min. Telcordia SR-332 (Bellcore) ; 389.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 145*60*32mm (L*W*H)
- PACKING
- 0.45Kg; 30pcs/14.05Kg/0.9CUFT
CONNECTOR
- PLUG
- See page 4~5 ; Other type available by customer requested
- CABLE
- See page 4~5 ; Other type available by customer requested
Test conditions and notes9
- 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
- 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
- 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μF & 47μF capacitor.
- 4. Tolerance: includes set up tolerance, line regulation, load regulation.
- 5. Line regulation is measured from low line to high line at rated load.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 7. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Typical applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments
Downloads
Datasheet1
Certificates9
Test reports1
FAQ
What are the main electrical ratings of the Mean Well GST90A48-P1M?
This model is a 90W AC/DC desktop power supply with a 48V DC output. It is rated for 1.87A output current. The input range is universal at 90 to 264VAC, which helps support global B2B equipment deployments.
What type of DC plug does the GST90A48-P1M use?
The GST90A48-P1M uses Mean Well's P1M plug style. The listed standard DC plug size is 2.5mm ID x 5.5mm OD x 11mm length. Buyers should confirm their device requires this exact plug format before ordering.
Is the GST90A48-P1M suitable for commercial or industrial equipment?
It is built for professional equipment use where a regulated 48V, 90W external power supply is required. This model includes overload, over-voltage, and over-temperature protection, along with 91% typical efficiency and a typical power factor above 0.95 at 115VAC. Those features make it a strong fit for B2B applications that need a branded external PSU.
How energy efficient is the Mean Well GST90A48-P1M?
This model has a typical efficiency of 91%, the highest in the GST90A series, and a typical power factor above 0.91 at 230VAC and 0.95 at 115VAC at full load. That makes it a good choice for businesses that want lower power losses and improved energy performance.
What safety and compliance standards does this power supply meet?
The GST90A48-P1M is listed with multiple safety approvals including UL62368-1, CSA C22.2 No.62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, PSE J62368-1, CCC GB4943.1, and AS/NZS 62368.1. EMC compliance includes BS EN/EN55032 Class B, BS EN/EN61000-3-2/3, FCC Part 15/CISPR22 Class B, CNS15936, GB9254, and GB17625.1. These approvals are useful for OEM and business buyers working across regulated markets.
Can the GST90A48-P1M be used in demanding temperature environments?
The structured product data lists an operating temperature range of -30°C to 70°C, with output derating per the derating curve. That makes it suitable for many equipment environments where a standard consumer-grade adapter may not be sufficient. Final suitability still depends on the end equipment, enclosure, and overall thermal conditions.
What kind of AC input and enclosure design does this model use?
This power supply accepts a universal 90 to 264VAC input (or 127 to 370VDC) and uses an IEC320-C14 AC inlet, with the -V output not connected to AC FG. It has an LED power indicator, and the compact housing is listed at 145 x 60 x 32mm.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other GST90 Models
4 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well GST90A15-P1M Supply 90W 15V 6A | 90W | 15V | 6A | View |
| Mean Well GST90A24-P1M Power Supply 90W 24V 3.75A | 90W | 24V | 3.75A | View |
| Mean Well GST90A19-P1M Power Supply 90W 19V 4.74A | 90W | 19V | 4.74A | View |
| Mean Well GST90A12-P1M Power Supply 80W 12V 6.67A | 80W | 12V | 6.67A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.