Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
RSP-320-36 is the 36V output model of this series: rated current 8.9A, rated power 320.4W, typical efficiency 89.5%.
RSP-320 is a 320W single output enclosed type AC/DC power supply. This series operates for 88~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 70℃.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 90%
- Forced air cooling by built-in DC Fan with fan speed control function
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Operating altitude up to 5000 meters
- Optional conformal coating
- LED indicator for power on
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 36V
- RATED CURRENT
- 8.9A
- CURRENT RANGE
- 0 ~ 8.9A
- RATED POWER
- 320.4W
- RIPPLE & NOISE (max.)Note.2
- 220mVp-p
- VOLTAGE ADJ. RANGE
- 32.4 ~ 39.6V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.2%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1500ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 8ms at full load 230VAC /115VAC
INPUT
- VOLTAGE RANGENote.4
- 88 ~ 264VAC 124 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 89.5%
- AC CURRENT (Typ.)
- 4A/115VAC 2A/230VAC
- INRUSH CURRENT (Typ.)
- 20A/115VAC 40A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 41.4 ~ 48.6V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
- OPERATING ALTITUDE
- 5000 meters
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1,EAC TP TC 004, CCC GB4943.1,BSMI CNS15598-1, AS/NZS 60950.1, IS13252(Part1)/ IEC60950-1(except for 2.5V,48V),Dekra EN 61558-1/2-16,IEC 61558-1/2-16(for 12V or higher models) approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/ EN55032 (CISPR32) Class B, BS EN/ EN61000-3-2,-3, EAC TP TC 020, CNS15936 , GB9254 Class B , GB17625.1
- EMC IMMUNITY
- Compliance to BS EN/ EN61000-4-2,3,4,5,6,8,11, BS EN/ EN55035, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 1826.4K hrs min. Telcordia SR-332 (Bellcore) ; 192.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 215*115*30mm (L*W*H)
- PACKING
- 0.9Kg; 15pcs/14.5Kg/0.67CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 7. For charging related applications, please consult Mean Well for details.
- 8. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: RSP-320-2.5/-3.3/-4/-5/-7.5/-12/-13.5/-15)
Technical drawings
Typical applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- RF application
Downloads
FAQ
What equipment uses 36V DC that the RSP-320-36 can serve?
The RSP-320-36 provides 36V at 8.9A (320W), suitable for powering certain brushless DC motors, industrial field instruments, and relay-controlled actuator systems that specify a 36V nominal rail.
Is the RSP-320-36 suitable for low-temperature enclosed environments?
Yes. The RSP-320-36 operates from -30°C to +70°C (derating per curve at higher temperatures), making it appropriate for cold-climate indoor enclosures. It is not rated for direct outdoor or wet-area use.
How does the RSP-320-36 compare to the RSP-320-27 and RSP-320-48 in the same series?
All three share the 215.0 × 115.0 × 30.0 mm form factor and 88-264VAC input. The RSP-320-27 provides 320W at 11.9A, the RSP-320-36 provides 320W at 8.9A, and the RSP-320-48 provides 320W at 6.7A. Current output decreases proportionally as voltage increases while total power stays near 320W.
Does the RSP-320-36 carry global safety certifications?
Yes. The RSP-320-36 is approved to UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, CCC GB4943.1 and BSMI CNS15598-1. The unit weighs 0.9 kg.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.