Overview
RSP-1600-12 is the 12V output model of this series: rated current 125A, rated power 1500W, typical efficiency 89%.
RSP-1600 is a 1.6KW single output enclosed type AC/DC power supply with a 1U low profile and a high power density up to 25W/inch³. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the thermostatically controlled fan. Moreover, RSP-1600 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Features
- Universal AC input / Full range (Withstand 300VAC surge input for 5 seconds)
- Built-in active PFC function
- High efficiency up to 93%
- Forced air cooling by built-in DC fan
- Output voltage and constant current level programmable
- Active current sharing up to 9600W (5+1)
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal / OTP alarm signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional PMBus or CANBus protocol
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 125A
- CURRENT RANGE
- 0 ~ 125A
- RATED POWER
- 1500W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 11.5 ~ 15V
- VOLTAGE TOLERANCENote.4
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1500ms, 60ms/230VAC at full load
- HOLD UP TIME (Typ.)
- 16ms / 230VAC at 75% load 10ms / 230VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 264VAC 250 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- 0.97/230VAC at full load
- EFFICIENCY (Typ.)
- 89%
- AC CURRENT (Typ.)Note.5
- 14A/115VAC 8A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 35A/230VAC
- LEAKAGE CURRENT
- <2mA / 230VAC
PROTECTION
- OVERLOAD
- 105 ~ 115% rated current Protection type : Constant current limiting, shut down O/P voltage after 5 sec. After O/P voltage falls, re-power on to recover
- OVER VOLTAGE
- 15.75 ~ 18.75V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Protection type : Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- OUTPUT VOLTAGE PROGRAMMABLE(PV)Note 6
- Adjustment of output voltage is allowable to 40 ~ 125% of nominal output voltage (60 ~ 125% for 12V). Please refer to the Function Manual.
- OUTPUT CURRENT PROGRAMMABLE(PC)Note 6
- Adjustment of constant current level is allowable to 20 ~ 100% of rated current. Please refer to the Function Manual.
- AUXILIARY POWER
- 5V @ 0.3A, 12V @ 0.8A
- REMOTE ON-OFF CONTROL
- By electrical signal or dry contact Power ON:short Power OFF:open. Please refer to the Function Manual
- REMOTE SENSE
- Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual
- ALARM SIGNAL
- Isolated signal output for T-alarm and DC OK
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/ EN55032 (CISPR32), CNS15936 Class B Radiated BS EN/ EN55032 (CISPR32), CNS15936 Class A Harmonic Current BS EN/ EN61000-3-2 Class A Voltage Flicker BS EN/ EN61000-3-3 - EMC IMMUNITY
-
BS EN/ EN55035, BS EN/ EN61000-6-2, BSMI CNS13438
Parameter Standard Test Level ESD BS EN/ EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/ EN61000-4-3 Level 3 EFT / Burst BS EN/ EN61000-4-4 Level 3 Surge BS EN/ EN61000-4-5 Level 4, 2KV/Line-Line 4KV/Line-Earth Conducted BS EN/ EN61000-4-6 Level 3 Magnetic Field BS EN/ EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/ EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 478.8K hrs min. Telcordia SR-332 (Bellcore) ; 42.1K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 300*85*41mm (L*W*H)
- PACKING
- 2.1Kg;6pcs/13.6Kg/1.25CUFT
Test conditions and notes9
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Under parallel operation ripple of the output voltage may be higher than the SPEC at light load condition. It will go back to normal ripple level once the output load is more than 5%.
- 4. Tolerance : includes set up tolerance, line regulation and load regulation.
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. PV/PC functions when users are not operating on PMBus/CANBus. SVR functions when users are neither operating on PMBus/CANBus nor using PV/PC.
- 7. Output will shut down after O/P voltage is below < 80% of Vset for 5 sec, re-power on to recover.
- 8. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Aging facility
- Digital broadcasting
- Constant current source
- Redundant system
Downloads
Certificates4
Test reports1
FAQ
How does the RSP-1600-12 differ from the RSP-1500-12 at the same voltage and current?
The RSP-1600-12 delivers 12V at 125A (1500W) with a typical efficiency of 89%. It features a compact 1U chassis measuring 300 x 85 x 41 mm. The unit supports active current sharing up to 9600W (5+1 configuration).
What does the active current sharing (5+1) capability mean for system design?
Active current sharing (5+1) allows up to five RSP-1600-12 units to operate in parallel with balanced loads, delivering up to 625A at 12V combined. A sixth unit provides N+1 hot standby. This enables larger redundant 12V bus designs.
What industrial applications are appropriate for the RSP-1600-12?
The RSP-1600-12 delivers 12V at 125A (1500W) and is suited for factory control or automation apparatus, test and measurement instruments, laser related machines, aging facilities, digital broadcasting, constant current sources, and redundant systems. The 90–264VAC input supports worldwide single-phase supply.
What is the operating temperature range of the RSP-1600-12?
The RSP-1600-12 operates from -30°C to +70°C ambient. This range is suitable for cold-start applications in unheated enclosures. No IP rating is specified.
What certifications does the RSP-1600-12 carry?
The RSP-1600-12 holds UL62368-1, CAN/CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, BSMI CNS15598-1, AS/NZS62368.1, and EAC TP TC 004 approvals.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.