Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
RSP-1500-12 is the 12V output model of this series: rated current 125A, rated power 1500W, typical efficiency 87%.
RSP-1500 is a 1.5KW single output enclosed type AC/DC power supply. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan working for the temperature up to 70℃. Moreover, RSP-1500 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 91%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 6000W (3+1)
- Built-in remote ON-OFF control / remote sense / auxiliary power / power OK signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 125A
- CURRENT RANGE
- 0 ~ 125A
- RATED POWER
- 1500W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 10 ~ 13.5V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1500ms, 100ms at full load
- HOLD UP TIME (Typ.)
- 10ms at full load
INPUT
- VOLTAGE RANGE
- 90 ~ 264VAC 250 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- 0.95/230VAC 0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 87%
- AC CURRENT (Typ.)
- 17A/115VAC 8A/230VAC
- INRUSH CURRENT (Typ.)
- 30A/115VAC 60A/230VAC
- LEAKAGE CURRENT
- <2.0mA / 240VAC
PROTECTION
- OVERLOADNote.4
- 105 ~135% rated output power Protection type : Constant current limiting unit will shut down o/p voltage after 5sec. Re-power on to recover
- OVER VOLTAGE
- 13.8 ~ 16.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- OUTPUT VOLTAGE PROGRAMMABLE(PV)
- Adjustment of output voltage is allowable to 70 ~ 100% of nominal output voltage. Please refer to the Function Manual.
- CURRENT SHARING
- Up to 6000W or (3+1) units. Please refer to the Function Manual.
- AUXILIARY POWER
- 12V@0.1A(Only for Remote ON-OFF control)
- REMOTE ON-OFF CONTROL
- Please see the Function Manual.
- REMOTE SENSE
- Compensate voltage drop on the load wiring up to 0.3V. Please refer to the Function Manual.
- ALARM SIGNAL OUTPUT
- Power OK signal. Please see the Function Manual.
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.05%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, CAN/CSA C22.2 No. 62368-1 , TUV BS EN/ EN62368-1, BSMI CNS15598-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/ EN55032 (CISPR32), BSMI CNS15936 Class B/Class A (only for BSMI) Radiated BS EN/ EN55032 (CISPR32), BSMI CNS15936 Class A Harmonic Current BS EN/ EN61000-3-2 Voltage Flicker BS EN/ EN61000-3-3 - EMC IMMUNITY
-
BS EN/ EN55035, BS EN/ EN61000-6-2
Parameter Standard Test Level ESD BS EN/ EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/ EN61000-4-3 Level 3 EFT / Burst BS EN/ EN61000-4-4 Level 2 Surge BS EN/ EN61000-4-5 Level 3, 2KV/Line-Earth; Level 2, 1KV/Line-Line Conducted BS EN/ EN61000-4-6 Level 3 Magnetic Field BS EN/ EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/ EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 814.4K hrs min. Telcordia SR-332 (Bellcore) ; 90.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 278*127*83.5mm (L*W*H)
- PACKING
- 3.0Kg; 4pcs/13Kg/1.19CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 720mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- Digital broadcasting
- RF application
Downloads
Certificates4
Test reports1
FAQ
What heavy-industrial applications can the RSP-1500-12 serve at 1500W?
The RSP-1500-12 delivers 12V at 125A (1500W) and is designed for high-current 12V bus applications such as large automation panels with many actuators, DC motor drive banks, industrial lighting control, and centralized 12V distribution in large machinery. The 90–264VAC input supports worldwide single-phase supplies.
What does the active current sharing (3+1) capability provide for the RSP-1500-12?
Active current sharing allows RSP-1500-12 units to operate in parallel with balanced loads, up to 6000W or (3+1) units. Total output current must not exceed rated current × number of units × 0.9, so three units deliver up to 337.5A at 12V, with a fourth unit providing the +1 redundancy. This suits 12V bus systems that cannot tolerate a single point of failure in the power supply chain.
What is the operating temperature range of the RSP-1500-12?
The RSP-1500-12 operates from -20°C to +70°C ambient, with load derating at higher temperatures according to the derating curve. No IP rating is specified; an appropriate enclosure is required for harsh environments.
What efficiency does the RSP-1500-12 achieve?
The RSP-1500-12 features built-in PFC (power factor 0.98 at 115VAC, 0.95 at 230VAC) and achieves 87% typical efficiency. At the rated 1500W output, this corresponds to approximately 1724W input power and about 224W of heat dissipation, which should be accounted for in enclosure thermal design.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.