Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
RSP-1000-12 is the 12V output model of this series: rated current 60A, rated power 720W, typical efficiency 83%.
RSP-1000 is a 1KW single output enclosed type AC/DC power supply with 1U low profile. This series operates for 90~264VAC input voltage and offers the models with the DC output mostly demanded from the industry. Each model is cooled by the built-in fan with fan speed control, working for the temperature up to 60℃. Moreover, RSP-1000 provides vast design flexibility by equipping various built-in functions such as the output programming, active current sharing, remote ON-OFF control, auxiliary power, etc.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 90%
- Forced air cooling by built-in DC fan
- Output voltage programmable
- Active current sharing up to 4000W (3+1)
- Built-in remote ON-OFF control / remote sense / auxiliary power / DC OK signal
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Optional conformal coating
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 60A
- CURRENT RANGE
- 0 ~ 60A
- RATED POWER
- 720W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 10 ~ 13.5V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 300ms, 50ms at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- 0.95/230VAC 0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 83%
- AC CURRENT (Typ.)
- 12A/115VAC 6A/230VAC
- INRUSH CURRENT (Typ.)
- 25A/115VAC 40A/230VAC
- LEAKAGE CURRENT
- <2.0mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 125% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 13.8 ~ 16.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
FUNCTION
- OUTPUT VOLTAGE PROGRAMMABLE(PV)
- Adjustment of output voltage is allowable to 40 ~ 110% of nominal output voltage. Please refer to the Function Manual.
- CURRENT SHARING
- Up to 4000W or (3+1) units. Please refer to the Function Manual.
- AUXILIARY POWER
- 5V @ 0.5A (+5%, -8%)
- REMOTE ON-OFF CONTROL
- Power ON : short Power OFF : open. Please refer to the Function Manual.
- REMOTE SENSE
- Compensate voltage drop on the load wiring up to 0.5V. Please refer to the Function Manual.
- DC OK SIGNAL
- The TTL signal out, PSU turn on = 0 ~ 1V ; PSU turn off = 3.3 ~ 5.6V. Please refer to the Function Manual.
ENVIRONMENT
- WORKING TEMP.
- -20 ~ +60℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.02%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, CSA C22.2 No. 62368-1, TUV BS EN/EN62368-1, CCC GB4943.1, BSMI CNS15598-1, AS/NZS62368.1, IS13252(Part1)/IEC60950-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/ EN55032 (CISPR32), CNS15936 Class B Radiated BS EN/ EN55032 (CISPR32), CNS15936 Class A Harmonic Current BS EN/ EN61000-3-2 Voltage Flicker BS EN/ EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55035, BS EN/EN61000-6-2, CCC GB17625.1, GB/T9254, BSMI CNS13438
Parameter Standard Test Level ESD BS EN/ EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/ EN61000-4-3 Level 3 EFT / Burst BS EN/ EN61000-4-4 Level 3 Surge BS EN/ EN61000-4-5 Level 4, 4KV/Line-Earth; Level 3, 2KV/Line-Line Conducted BS EN/ EN61000-4-6 Level 3 Magnetic Field BS EN/ EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/ EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 peniods, >95% interruptions 250 periods
OTHERS
- MTBF
- 939.4K hrs min. Telcordia SR-332 (Bellcore) ; 116.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 295*127*41mm (L*W*H)
- PACKING
- 1.95Kg; 6pcs/12.7Kg/1.15CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Typical applications
- Factory control or automation apparatus
- Test and measurement instrument
- Laser related machine
- Burn-in facility
- RF application
Downloads
Certificates4
Test reports1
FAQ
What high-power industrial applications is the RSP-1000-12 suited for?
The RSP-1000-12 delivers 12V at 60A (720W) and is designed for high-current 12V DC bus applications including industrial machine control systems, multi-axis motion controllers, large relay panels, and centralized 12V distribution in automation cells. The 90–264VAC input supports worldwide single-phase supply.
What does the active current sharing (3+1) feature mean for the RSP-1000-12?
Active current sharing (3+1) means up to three RSP-1000-12 units can operate in parallel to triple the output current to 180A while a fourth unit can serve as a hot standby for N+1 redundancy. This allows the system to sustain 60A per operating unit with automatic load balancing, improving both capacity and reliability.
How does the RSP-1000-12 compare to the other RSP-1000 voltage variants?
The RSP-1000 series is available in five voltage options: RSP-1000-12 (720W/12V/60A), RSP-1000-15 (750W/15V/50A), RSP-1000-24 (960W/24V/40A), RSP-1000-27 (999W/27V/37A), RSP-1000-48 (1008W/48V/21A). All share the same 295.0 × 127.0 × 41.0 mm form factor, 90–264VAC input, -20°C to +60°C operating range, and 5-year warranty. The 12V variant provides the highest current at 60A.
What is the operating temperature range of the RSP-1000-12 and how does it affect deployment?
The RSP-1000-12 operates from -20°C to +60°C ambient. Note that the upper limit is +60°C rather than the +70°C found in smaller RSP-100/150/200 models. In higher ambient environments, ensure the enclosure provides adequate cooling to keep ambient at or below +60°C for this unit.
Does the RSP-1000-12 include active PFC and how efficient is it?
Yes. The RSP-1000-12 includes built-in active PFC and achieves up to 91% efficiency. This means at full 720W output, input losses are approximately 79W, reducing heat dissipation and lowering operating costs compared to lower-efficiency supplies at this power level.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.