Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
RS-50-48 is the 48V output model of this series: rated current 1.1A, rated power 52.8W, typical efficiency 89%.
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105℃ long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70℃
- Withstand 5G vibration test
- No load power consumption<0.5W
- High efficiency, long life and high reliability
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- RATED CURRENT
- 1.1A
- CURRENT RANGE
- 0 ~ 1.1A
- RATED POWER
- 52.8W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- 42 ~ 54V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATIONNote.4
- ±0.5%
- LOAD REGULATIONNote.5
- ±0.5%
- SETUP, RISE TIME
- 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 60ms/230VAC 14ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY(Typ.)
- 89%
- AC CURRENT (Typ.)
- 1.3A/115VAC 0.8A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 33A/230VAC
- LEAKAGE CURRENT
- <2mA / 240VAC
PROTECTION
- OVERLOAD
- 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 55.2 ~ 64.8V Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1 , EAC TP TC 004, CCC GB4943.1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 2956.7K hrs min. Telcordia SR-332 (Bellcore) ; 575.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 99*97*36mm (L*W*H)
- PACKING
- 0.41Kg; 45pcs/19.5Kg/0.94CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Line regulation is measured from low line to high line at rated load.
- 5. Load regulation is measured from 0% to 100% rated load.
- 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the RS-50-48 for a 48V industrial control device or automation module?
Yes, this model is a constant-voltage 48V supply rated for 52.8W and 1.1A. It fits 48V industrial or automation loads that stay within that output range.
Is the RS-50-48 a good fit for a small 48V embedded system or communications enclosure?
It can be, as long as the equipment requires 48V constant voltage and does not exceed 1.1A or 52.8W. Its compact 99.0 x 97.0 x 36.0 mm size can also help where enclosure space is limited.
Can this power supply run a 48V automation accessory in a vibration-prone machine area?
This unit is specified to withstand 5G vibration, so it is better suited to industrial equipment than a basic open-frame supply with no vibration detail listed. The load still needs to match its 48V, 1.1A, and 52.8W output limits.
Would the RS-50-48 work for a low-power 48V control panel device?
Yes, it is intended for constant-voltage 48V applications and provides up to 1.1A. That makes it a practical option for lower-power 48V panel devices rather than larger 48V loads.
Is the RS-50-48 suitable for outdoor use or harsh temperature conditions?
The operating temperature range is -25C to +70C, so it covers a wide temperature span. No IP rating is listed in the provided specs, so outdoor suitability should not be assumed from this data alone.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.