Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
RS-50-12 is the 12V output model of this series: rated current 4.2A, rated power 50.4W, typical efficiency 84.5%.
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- LED indicator for power on
- 100% full load burn-in test
- All using 105℃ long life electrolytic capacitors
- Withstand 300VAC surge input for 5 second
- High operating temperature up to 70℃
- Withstand 5G vibration test
- No load power consumption<0.5W
- High efficiency, long life and high reliability
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 4.2A
- CURRENT RANGE
- 0 ~ 4.2A
- RATED POWER
- 50.4W
- RIPPLE & NOISE (max.)Note.2
- 120mVp-p
- VOLTAGE ADJ. RANGE
- 10.8 ~ 13.2V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATIONNote.4
- ±0.5%
- LOAD REGULATIONNote.5
- ±0.5%
- SETUP, RISE TIME
- 500ms, 30ms/230VAC 1200ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 60ms/230VAC 14ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 88 ~ 264VAC 125 ~ 373VDC (Withstand 300VAC surge for 5sec. Without damage)
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY(Typ.)
- 84.5%
- AC CURRENT (Typ.)
- 1.3A/115VAC 0.8A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 33A/230VAC
- LEAKAGE CURRENT
- <2mA / 240VAC
PROTECTION
- OVERLOAD
- 110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 13.8 ~ 16.2V Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1 , AS/NZS 62368.1 , EAC TP TC 004, CCC GB4943.1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3,GB9254 class B,GB17625.1, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 2956.7K hrs min. Telcordia SR-332 (Bellcore) ; 575.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 99*97*36mm (L*W*H)
- PACKING
- 0.41Kg; 45pcs/19.5Kg/0.94CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Line regulation is measured from low line to high line at rated load.
- 5. Load regulation is measured from 0% to 100% rated load.
- 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the RS-50-12 for a 12V HMI, control panel accessory, or small automation device?
Yes, if the equipment needs a constant 12V supply and draws no more than 4.2A or 50.4W. That makes it appropriate for many compact industrial and automation loads built around a 12V DC input.
Is the RS-50-12 suitable for 12V industrial sensors, relays, or alarm electronics?
It is suitable for 12V constant-voltage devices as long as the total load remains within 4.2A and 50.4W. It fits low-power control and monitoring hardware that is specified for 12V DC operation.
Can this power supply run a 12V embedded or communications device in a machine cabinet?
It can, provided the device requires 12V constant voltage and stays under 4.2A with 50.4W total demand. The wide 88-264VAC input also makes it practical for equipment deployed across different AC mains environments.
How does the RS-50-12 compare with other 12V RS series models?
The RS-50 series includes 12V models such as the RS-15-12 (15.6W, 1.3A), RS-25-12 (25.2W, 2.1A), RS-35-12 (35W, 3A), RS-50-12 (50.4W, 4.2A), RS-75-12 (72W, 6A), RS-100-12 (102W, 8.5A), and RS-150-12 (150W, 12.5A). The RS-50-12 is the mid-range 12V option between the 35W and 72W models.
Can the RS-50-12 be used in hot, cold, or vibration-prone indoor industrial settings?
The unit is rated for -25°C to +70°C operation and is specified to withstand 5G vibration. No IP rating is provided, so the specs support use in protected indoor equipment environments rather than open outdoor exposure.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.