Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well RID-125-2448 AC-DC Dual output enclosed power supply 125W 22A

miniature sizeeconomicalwithstand 5G vibration and 70°C operationisolated dual output
SKU RID-125-2448
$45.45 USD
Shipping calculated at checkout.
In stock
|

Overview

RID-125-2448 is the CH1: 24V / CH2: 48V output model of this series: rated current CH1: 2A / CH2: 2A, rated power 144W, typical efficiency 86%.

Features

  • Isolated output & GND for CH1,CH2
  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage
  • All using 105℃ long life electrolytic capacitors
  • Withstand 5G vibration test
  • LED indicator for power on
  • 100% full load burn-in test
  • High realibility
  • 3 years warranty

Specifications

RID-125-2448Specifications from the official datasheet (2025-12-19 edition)

OUTPUT

OUTPUT NUMBER
CH1 / CH2
DC VOLTAGE
CH1: 24V / CH2: 48V
RATED CURRENT
CH1: 2A / CH2: 2A
CURRENT RANGENote.3
CH1: 0 ~ 4A / CH2: 0 ~ 2.5A
RATED POWERNote.6
144W
RIPPLE & NOISE (max.)Note.2
CH1: 200mVp-p / CH2: 240mVp-p
VOLTAGE ADJ. RANGE
CH1: 22.8 ~ 26.4V
VOLTAGE TOLERANCENote.3
CH1: ±1.0% / CH2: ±6.0%
LINE REGULATIONNote.4
CH1: ±0.5% / CH2: ±1.0%
LOAD REGULATIONNote.5
CH1: ±1.0% / CH2: ±5.0%
SETUP, RISE TIME
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
36ms/230VAC 30ms/115VAC at full load

INPUT

VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(300VAC peak 5sec. No damage)
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY(Typ.)
86%
AC CURRENT (Typ.)
3A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.)
COLD START 50A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC

PROTECTION

OVERLOAD
110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
CH1: 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.
-20 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)on CH1 output
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC (Note 7)

SAFETY STANDARDS
UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2(Note 9),-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020

OTHERS

MTBF
2755.4K hrs min. Telcordia SR-332 (Bellcore) ; 425.8K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
199*98*38mm (L*W*H)
PACKING
0.59Kg; 20pcs/12.85Kg/0.85CUFT
Test conditions and notes10
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.(In order to meet tolerance, it is recommended that CH1 load > 5% rated current.)
  4. 4. Line regulation is measured from low line to high line at rated load.
  5. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. 6. Each output can work within current range. But total output power can't exceed rated output power.
  7. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  8. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  9. 9. Testing harmonic current at 85%load.
  10. 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

RID-125-2448 Mechanical Specification
Mechanical Specification
RID-125-2448 Block Diagram
Block Diagram
RID-125-2448 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the RID-125-2448 for a 24V industrial control panel load?

This model is aimed at 24V DC applications and is rated at 144W with 2A output current on CH1. That makes it a fit for industrial control panels, automation assemblies, and other equipment that specifically requires 24V DC within that power range.

Is the RID-125-2448 suitable for 24V automation and machine subsystems?

It can be used for 24V automation subsystems that need up to 144W and 2A on CH1. The enclosed design and isolated dual output format make it more appropriate for protected machine or cabinet environments than exposed field mounting.

Can this power supply support 24V embedded or industrial electronics in a compact enclosure?

Yes, if the equipment is designed for 24V DC and stays within the 144W and 2A ratings. Its 199.0 × 98.0 × 38.0 mm size is useful where enclosure space matters, and the unit is specified for operation up to +70°C.

Is the RID-125-2448 OK for outdoor or washdown locations?

The provided specs list it as an enclosed power supply, but no IP rating is given. That means it is better suited to protected indoor enclosures and controlled industrial spaces rather than outdoor, wet, or washdown exposure.

How does the RID-125-2448 compare with other Mean Well RID series models?

Within the listed siblings, RID-125-2448 is 144W at 24V/48V. Other listed models are RID-125-1205 at 125.4W, 12V/5V; RID-125-1224 at 133.2W, 12V/24V; RID-125-1248 at 138W, 12V/48V; RID-125-2405 at 125.4W, 24V/5V; RID-50A at 50W, 5V, 2A; RID-50B at 50W, 5V, 1.4A; RID-65A at 65W, 5V, 3A; RID-65B at 65W, 5V, 2A; RID-85A at 85W, 5V, 4A; and RID-85B at 85W, 5V, 2A.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8650635149632, "variants" :[{ "context":"default", "variant_id": 46615515398464, "sku":"RID-125-2448", "inventory_qty" : 8, "customer" :true, "custom_html" :"\u003cdiv class=\"price\"\u003e\n \u003cdiv class=\"price__default\"\u003e\n \u003cstrong class=\"price__current\"\u003e$45.45\u003c\/strong\u003e\n \u003cs class=\"price__was\"\u003e\u003c\/s\u003e\n \u003c\/div\u003e\n\n \u003cdiv class=\"unit-price relative\" hidden\u003e\u003cspan class=\"visually-hidden\"\u003eUnit price\u003c\/span\u003e\u003cspan class=\"unit-price__price\"\u003e\u003c\/span\u003e\u003cspan class=\"unit-price__separator\"\u003e \/ \u003c\/span\u003e\u003cspan class=\"unit-price__unit\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv class=\"price__no-variant\" hidden\u003e\n \u003cstrong class=\"price__current\"\u003eUnavailable\u003c\/strong\u003e\n \u003c\/div\u003e\n\n \u003c\/div\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well RID-125-2448 AC-DC Dual output enclosed power supply 125W 22A
Mean Well

Mean Well RID-125-2448 AC-DC Dual output enclosed power supply 125W 22A

$45.45 USD

RID-125-2448 is the CH1: 24V / CH2: 48V output model of this series: rated current CH1: 2A / CH2: 2A, rated power 144W, typical efficiency 86%.

Features

  • Isolated output & GND for CH1,CH2
  • AC input range selectable by switch
  • Withstand 300VAC surge input for 5 seconds
  • Protections: Short circuit / Overload / Over voltage
  • All using 105℃ long life electrolytic capacitors
  • Withstand 5G vibration test
  • LED indicator for power on
  • 100% full load burn-in test
  • High realibility
  • 3 years warranty
View product