Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
RID-125-2405 is the CH1: 24V / CH2: 5V output model of this series: rated current CH1: 4.6A / CH2: 3A, rated power 125.4W, typical efficiency 83%.
Features
- Isolated output & GND for CH1,CH2
- AC input range selectable by switch
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage
- 170% peak load for CH1
- All using 105℃ long life electrolytic capacitors
- Withstand 5G vibration test
- LED indicator for power on
- 100% full load burn-in test
- High realibility
- 3 years warranty
Specifications
OUTPUT
- OUTPUT NUMBER
- CH1 / CH2
- DC VOLTAGE
- CH1: 24V / CH2: 5V
- RATED CURRENT
- CH1: 4.6A / CH2: 3A
- CURRENT RANGENote.6
- CH1: 0 ~ 5.3A / CH2: 0 ~ 3A
- PEAK LOADNote.9
- CH1: 7.8A / CH2: 3A
- RATED POWER
- 125.4W
- RIPPLE & NOISE (max.)Note.2
- CH1: 120mVp-p / CH2: 80mVp-p
- VOLTAGE ADJ. RANGE
- CH1: 22.8 ~ 26.4V
- VOLTAGE TOLERANCENote.3
- CH1: ±2.0% / CH2: ±3.0%
- LINE REGULATIONNote.4
- CH1: ±0.5% / CH2: ±0.5%
- LOAD REGULATIONNote.5
- CH1: ±1.0% / CH2: ±2.0%
- SETUP, RISE TIME
- 500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 35ms/230VAC 30ms/115VAC at full load
INPUT
- VOLTAGE RANGE
- 88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(300VAC peak 5sec., no damage)
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY(Typ.)
- 83%
- AC CURRENT (Typ.)
- 3A/115VAC 2A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 50A/230VAC
- LEAKAGE CURRENT
- <2mA / 240VAC
PROTECTION
- OVERLOAD
- >165% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- CH1: 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENT
- WORKING TEMP.
- -25 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)on CH1 output
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 7)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2(Note 10),-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 218.2Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 199*98*38mm (L*W*H)
- PACKING
- 0.59Kg; 20pcs/12.85Kg/0.85CUFT
Test conditions and notes11
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Line regulation is measured from low line to high line at rated load.
- 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
- 6. Each output can work within current range. But total output power can't exceed rated output power.
- 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
- 9. 10% duty cycle maximum within every second. Average output power should not exceed the rated power.
- 10. Testing harmonic current at 85%load.
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Certificates1
FAQ
Can I use the RID-125-2405 for 5V embedded computing or controller boards in industrial equipment?
It can fit 5V embedded computing or controller boards when the load stays within its 3A output current and 125W power rating. The enclosed design supports use inside industrial equipment rather than in exposed environments.
Is the RID-125-2405 suitable for 5V HMI, display, or interface electronics?
Yes, it is aligned with 5V electronics such as display or interface hardware because the rated output is 5V at 3A. It is best matched to equipment that specifically requires a 5V rail.
Can the RID-125-2405 power 5V monitoring or communications hardware in automation systems?
This model can support 5V monitoring or communications hardware if the total load remains within 3A and 125W. The isolated dual-output design can also matter in systems where output separation is required.
Is the RID-125-2405 rated for indoor control cabinets or exposed outdoor use?
Its operating temperature range is -25°C to +70°C, so it is suitable for a broad range of indoor equipment conditions. The provided specifications do not include an IP rating, so exposed outdoor use is not confirmed.
How does the RID-125-2405 differ from the other RID models in this group?
The sibling list includes RID-125-1205 at 125W, 12V/5V; RID-125-1224 at 133.2W, 12V/24V; RID-125-1248 at 138W, 12V/48V; RID-125-2448 at 144W, 24V/48V. The RID-125-2405 is the 125.4W model with 24V and 5V outputs.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.