Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well RD-125-2448 AC-DC Dual output enclosed power supply 125W 2A

miniature sizeeconomicalwithstand 5G vibration and 70°C operationdual output
SKU RD-125-2448
$38.53 USD
Shipping calculated at checkout.
Model

Select model — 3 in this family

RD-125-2448
In stock
|

Overview

RD-125-2448 is the 24V / 48V output model of this series: rated current 2A / 2A, rated power 144W, typical efficiency 86%.

Features

  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105℃ long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70℃
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

Specifications

RD-125-2448Specifications from the official datasheet (2025-12-19 edition)

OUTPUT

OUTPUT NUMBER
CH1 / CH2
DC VOLTAGE
24V / 48V
RATED CURRENT
2A / 2A
CURRENT RANGENote.3
0 ~ 4A / 0 ~ 2.5A
RATED POWERNote.6
144W
RIPPLE & NOISE (max.)Note.2
200mVp-p / 240mVp-p
VOLTAGE ADJ. RANGE
CH1: 22.8 ~ 26.4V
VOLTAGE TOLERANCENote.3
±1.0% / ±6.0%
LINE REGULATIONNote.4
±0.5% / ±1.0%
LOAD REGULATIONNote.5
±1.0% / ±5.0%
SETUP, RISE TIME
500ms, 20ms/230VAC 1200ms, 30ms/115VAC at full load
HOLD UP TIME (Typ.)
25ms/230VAC 30ms/115VAC at full load

INPUT

VOLTAGE RANGE
88 ~ 132VAC / 176 ~ 264VAC selected by switch 248 ~ 373VDC(Withstand 300VAC surge for 5sec. Without damage)
FREQUENCY RANGE
47 ~ 63Hz
EFFICIENCY (Typ.)
86%
AC CURRENT (Typ.)
3A/115VAC 2A/230VAC
INRUSH CURRENT (Typ.)
COLD START 50A/230VAC
LEAKAGE CURRENT
<2mA / 240VAC

PROTECTION

OVERLOAD
110 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
CH1: 27.6 ~ 32.4V Protection type : Hiccup mode, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.
-25 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)on CH1 output
VIBRATION
10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC (Note 7)

SAFETY STANDARDS
UL62368-1, TUV BS EN/EN62368-1, IS 13252(Part 1)(only for RD-125-1224), EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2(Note 9),-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN61000-6-2 (BS EN/EN50082-2), heavy industry level, EAC TP TC 020

OTHERS

MTBF
2755.4K hrs min. Telcordia SR-332 (Bellcore) ; 425.8K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
199*98*38mm (L*W*H)
PACKING
0.59Kg; 20pcs/12.85Kg/0.85CUFT
Test conditions and notes10
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.(In order to meet tolerance, it is recommended that CH1 load > 5% rated current.)
  4. 4. Line regulation is measured from low line to high line at rated load.
  5. 5. Load regulation is measured from 20% to 100% rated load, and other output at 60% rated load.
  6. 6. Each output can work within current range. But total output power can't exceed rated output power.
  7. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  8. 8. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  9. 9. Testing harmonic current at 85%load.
  10. 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

RD-125-2448 Mechanical Specification
Mechanical Specification
RD-125-2448 Block Diagram
Block Diagram
RD-125-2448 Derating Curve
Derating Curve

Downloads

FAQ

Can I use the RD-125-2448 for a compact 24V control or automation enclosure?

Yes, this model provides a listed 24V output at 2A in a 144W enclosed AC-DC power supply format. That makes it relevant for smaller control or automation assemblies built around a 24V rail. Its 199.0 × 98.0 × 38.0 mm housing can also help in tighter enclosures.

Is the RD-125-2448 suitable for 24V embedded equipment that needs dual outputs?

It can be a fit where the equipment needs a 24V rail and benefits from a dual output power supply. The listed output is 24V at 2A, with total rated power of 144W. Its enclosed construction and 0.59 kg weight also make it practical for compact equipment builds.

Can this model be used in industrial monitoring or light process equipment with 24V electronics?

For light process or monitoring equipment using 24V electronics, the RD-125-2448 offers a 24V output at 2A in a 144W class supply. The features also specify 5G vibration resistance and operation up to +70°C. Those are relevant specs for indoor equipment exposed to more demanding operating conditions.

Is the RD-125-2448 designed for outdoor service or wide indoor temperature swings?

The operating temperature range is listed as -25°C to +70°C, so it is specified for wide-temperature indoor use. No IP rating appears in the provided specs, so the available data does not confirm outdoor ingress protection. The environmental details given are the temperature range and 5G vibration resistance.

How does the RD-125-2448 compare with other RD models in the same family list?

Within the 125W subgroup shown here, RD-125-1224 is 133.2W 12V 3.7A, RD-125-1248 is 138W 12V 2.3A, and this RD-125-2448 is 144W 24V 2A. The rest of the provided siblings include RD-125A at 130.9W 5V 7.7A, RD-125B at 133.4W 5V 4.6A, RD-3513 at 35.1W 13.5V 1.3A, RD-35A at 32W 5V 4A, RD-35B at 35W 5V 2.2A, RD-50A at 54W 5V 6A, RD-50B at 53.6W 5V 4A, RD-65A at 66W 5V 6A, RD-65B at 68W 5V 4A, and RD-85A and RD-85B at 88W 5V 8A. RD-125-2412, RD-125-4812, RD-125-4824, RD-125A-OB, RD-125NB, and RD-65A-OB are listed without complete specs in the provided data.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8650632298816, "variants" :[{ "context":"default", "variant_id": 46615509434688, "sku":"RD-125-2448", "inventory_qty" : 11, "customer" :true, "custom_html" :"\u003cdiv class=\"price\"\u003e\n \u003cdiv class=\"price__default\"\u003e\n \u003cstrong class=\"price__current\"\u003e$38.53\u003c\/strong\u003e\n \u003cs class=\"price__was\"\u003e\u003c\/s\u003e\n \u003c\/div\u003e\n\n \u003cdiv class=\"unit-price relative\" hidden\u003e\u003cspan class=\"visually-hidden\"\u003eUnit price\u003c\/span\u003e\u003cspan class=\"unit-price__price\"\u003e\u003c\/span\u003e\u003cspan class=\"unit-price__separator\"\u003e \/ \u003c\/span\u003e\u003cspan class=\"unit-price__unit\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv class=\"price__no-variant\" hidden\u003e\n \u003cstrong class=\"price__current\"\u003eUnavailable\u003c\/strong\u003e\n \u003c\/div\u003e\n\n \u003c\/div\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well RD-125-2448 AC-DC Dual output enclosed power supply 125W 2A
Mean Well

Mean Well RD-125-2448 AC-DC Dual output enclosed power supply 125W 2A

$38.53 USD

RD-125-2448 is the 24V / 48V output model of this series: rated current 2A / 2A, rated power 144W, typical efficiency 86%.

Features

  • Protections: Short circuit / Overload / Over voltage
  • Cooling by free air convection
  • LED indicator for power on
  • 100% full load burn-in test
  • All using 105℃ long life electrolytic capacitors
  • Withstand 300VAC surge input for 5 second
  • High operating temperature up to 70℃
  • Withstand 5G vibration test
  • High efficiency, long life and high reliability
  • 3 years warranty

Model

  • 125W 12V 24V
  • 125W 12V 48V
  • 125W 48V 24V
View product