Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well PLC-60-36 Power Supply 60W 36V - PFC 1.7A

screw terminalfully isolated plastic casesuitable for signage applications
SKU PLC-60-36
$39.98 USD
Shipping calculated at checkout.
Available to order
|

Overview

PLC-60-36 is the 36V output model of this series: rated current 1.7A, rated power 61.2W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • High efficiency up to 89%
  • Adjustable output voltage and current level
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • Fully isolated plastic case with terminal block style of I/O
  • Built-in active PFC function, comply with BS EN/EN61000-3-2 class C (≧75% load)
  • Class 2 power unit
  • Pass LPS
  • 100% full load burn-in test
  • High reliability

Specifications

PLC-60-36Specifications from the official datasheet (2026-02-09 edition)

OUTPUT

DC VOLTAGE
36V
CONSTANT CURRENT REGIONNote.6
25.2 ~ 36V
RATED CURRENT
1.7A
CURRENT RANGE
0 ~ 1.7A
RATED POWER
61.2W
RIPPLE & NOISE (max.)Note.2
3.6Vp-p
VOLTAGE ADJ. RANGENote.5
32.5 ~ 39V
CURRENT ADJ. RANGENote.5
1.275 ~ 1.751A
VOLTAGE TOLERANCENote.3
±10%
LINE REGULATION
±3.0%
LOAD REGULATION
±5.0%
SETUP TIME
500ms / 230VAC 3000ms / 115VAC at full load

INPUT

VOLTAGE RANGENote.4
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.92/115VAC, PF>0.9/230VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading≧75% at 115VAC/230VAC input
EFFICIENCY (Typ.)
89%
AC CURRENT (Typ.)
0.8A/115VAC 0.4A/230VAC
INRUSH CURRENT (Typ.)
COLD START 35A(twidth=35μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER
32 units (circuit breaker of type B) / 32 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 240VAC

PROTECTION

OVER CURRENT
95 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed.
OVER VOLTAGE
41 ~ 46V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.
-30 ~ +50℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL1310, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, CAN/CSA C22.2 No. 223-M91(except for 48V), EAC TP TC 004 approved
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧75% load) ; BS EN/EN61000-3-3,EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55024,BS EN/EN61547, light industry level ,EAC TP TC 020

OTHERS

MTBF
3445.4K hrs min. Telcordia SR-332 (Bellcore) 515.0Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
181.5*62*35mm (L*W*H)
PACKING
0.41Kg; 30pcs/13.3Kg/0.67CUFT

Certifications & ratings

Marked features
LPS, FC
Test conditions and notes11
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
  5. 5. Output voltage can be adjusted through the SVR1 on the PCB ; limit of output constant current level can be adjusted through the SVR2 on the PCB.
  6. 6. Please refer to "DRIVING METHODS OF LED MODULE".
  7. 7. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  8. 8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
  9. 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
  10. 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  11. 11. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)

Technical drawings

PLC-60-36 Mechanical Specification
Mechanical Specification
PLC-60-36 Block Diagram
Block Diagram
PLC-60-36 Derating Curve
Derating Curve
PLC-60-36 Power Factor Characteristic
Power Factor Characteristic
PLC-60-36 EFFICIENCY vs LOAD (48V Model)
EFFICIENCY vs LOAD (48V Model)

Typical applications

  • Suitable for LED lighting and moving sign applications (Note.2)
  • Compliance to worldwide safety regulations for lighting
  • 2 years warranty

Downloads

FAQ

What type of power supply is the Mean Well PLC-60-36?

The PLC-60-36 is a 60W class power supply with a 36V DC output and a rated current of 1.7A. It uses a constant-voltage design with built-in constant-current limiting and a 25.2-36V constant current region for driving LEDs. This makes it suitable for applications that need stable 36V output with added current-limiting behavior.

What applications is the PLC-60-36 commonly used for?

This model is intended for LED lighting and moving sign applications, in line with its design as an LED power supply. Its 36V output and built-in PFC make it a practical choice for commercial and industrial low-voltage lighting systems. Buyers typically consider it when they need a regulated 36V power supply from a recognized industrial brand.

Does the Mean Well PLC-60-36 include power factor correction?

Yes. The PLC-60-36 has built-in PFC, with PF>0.92 at 115VAC and PF>0.9 at 230VAC at full load according to the datasheet. That is a useful differentiator for buyers comparing it with basic non-PFC power supplies for commercial lighting projects.

Can the output on the PLC-60-36 be adjusted?

Yes. The datasheet states that output voltage (32.5-39V, via SVR1) and the constant current level (1.275-1.751A, via SVR2) are adjustable on the PCB. That gives buyers some flexibility when selecting the PLC-60-36 for systems that need fine-tuning within the product's intended operating range.

What operating temperatures can the PLC-60-36 handle?

The specified operating temperature range is -30°C to 50°C. That range supports use in a variety of indoor and protected commercial environments where low-voltage LED power supplies are used. Buyers should still confirm that the surrounding enclosure and overall system conditions stay within the product's rated limits.

Does the PLC-60-36 support dimming control?

No. The provided product data lists dimming control as none for the PLC-60-36. If a project requires integrated dimming, this model would generally be compared against other LED drivers or power supplies that explicitly include dimming functionality.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8650607100224, "variants" :[{ "context":"default", "variant_id": 46615391043904, "sku":"PLC-60-36", "inventory_qty" : 0, "customer" :true, "custom_html" :"\u003cdiv class=\"price\"\u003e\n \u003cdiv class=\"price__default\"\u003e\n \u003cstrong class=\"price__current\"\u003e$39.98\u003c\/strong\u003e\n \u003cs class=\"price__was\"\u003e\u003c\/s\u003e\n \u003c\/div\u003e\n\n \u003cdiv class=\"unit-price relative\" hidden\u003e\u003cspan class=\"visually-hidden\"\u003eUnit price\u003c\/span\u003e\u003cspan class=\"unit-price__price\"\u003e\u003c\/span\u003e\u003cspan class=\"unit-price__separator\"\u003e \/ \u003c\/span\u003e\u003cspan class=\"unit-price__unit\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv class=\"price__no-variant\" hidden\u003e\n \u003cstrong class=\"price__current\"\u003eUnavailable\u003c\/strong\u003e\n \u003c\/div\u003e\n\n \u003c\/div\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well PLC-60-36 Power Supply 60W 36V - PFC 1.7A
Mean Well

Mean Well PLC-60-36 Power Supply 60W 36V - PFC 1.7A

$39.98 USD

PLC-60-36 is the 36V output model of this series: rated current 1.7A, rated power 61.2W, typical efficiency 89%.

Features

  • Universal AC input / Full range
  • High efficiency up to 89%
  • Adjustable output voltage and current level
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • Built-in constant current limiting circuit
  • Fully isolated plastic case with terminal block style of I/O
  • Built-in active PFC function, comply with BS EN/EN61000-3-2 class C (≧75% load)
  • Class 2 power unit
  • Pass LPS
  • 100% full load burn-in test
  • High reliability

Typical applications

  • Suitable for LED lighting and moving sign applications (Note.2)
  • Compliance to worldwide safety regulations for lighting
  • 2 years warranty
View product