Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NPF-200-48 is the 48V output model of this series: rated current 4.17A, rated power 200.1W, typical efficiency 94%.
NPF-200 series is a 200W AC/DC LED driver featuring the constant current or constant voltage mode output. NPF-200 operates from 100~305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 94% with the fanless design, the entire series is able to operate for -40℃~+85℃ case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for a variety of applications at dry, damp or wet locations. NPF-200 is particulary design without flicker Dimming Function which is suitable for LED strip or Poultrey lighting applications.
Features
- Plastic housing with class II and PFC design
- Constant Voltage + Constant current mode output
- Standby power consumption <0.5W
- IP67 rating for indoor or outdoor installations
- Dimming function: 3 in 1 Dimming(C.V Dim. only) to adjust output voltage level
- Flicker free Design
- Typical lifetime >50000hours
- 5 years warranty
Specifications
OUTPUT
- DC Voltage
- 48V
- CONSTANT CURRENT AND OUTPUT VOLTAGE REGION
- 24 ~ 48V
- RATED CURRENT
- 4.17A
- RATED POWER
- 200.1W
- RIPPLE & NOISE (max.)Note.9
- 250mVp-p
- VOLTAGE TOLERANCENote.10
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- CURRENT TOLERANCE
- ±5.0%
- SET UP TIMENote.3
- 500ms/230VAC or 115VAC
- RISE TIME
- 80ms for Blank type, 200ms for V-type
- HOLD UP TIME (Typ.)
- 10ms/230VAC or 115VAC
INPUT
- VOLTAGE RANGENote.2
- 100 ~ 305VAC 142 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.97/115VAC, PF≧0.96/230VAC, PF≧0.94/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20%(@load≧60%/115VC, 230VAC; @load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
- EFFICIENCY(Typ.)
- 94%
- AC CURRENT (Typ.)
- 2.2A / 115VAC 1.1A / 230VAC 0.9A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 65A(twidth=550 μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. NO. of PSUs on 16A CIRCUIT BREAKER
- 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.25mA / 277VAC
- STANDBY POWER CONSUMPTION
- <0.5W for V-type only (Output voltage dim to off)
PROTECTION
- OVER CURRENT
- 95 ~ 108% Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode or Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 53 ~ 65V Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- Tcase=-40 ~ +85℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
- MAX. CASE TEMP.
- Tcase=+85℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750(type”HL”), CSA C22.2 No. 250.13-12, According to BS EN/EN61347-2-13 appendix J suitable for emergency installations. ENEC BS EN/EN61347-1, BS EN/EN61347-2-13, BS EN/EN62384 independent, EAC TP TC 004, GB/T19510.1,GB/T19510.213,IP67 approved; Design refer to BS EN/EN60335-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧60%) ; BS EN/EN61000-3-3; GB/T 17743, GB17625.1, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level(surge immunity Line-Line 2KV); EAC TP TC 020
OTHERS
- MTBF
- 2625.4K hrs min. Telcordia SR-332 (Bellcore) ; 247.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 195*68*39.5mm (L*W*H)
- PACKING
- 1.03Kg; 12pcs/ 13.4Kg/ 0.71CUFT
Certifications & ratings
- Type
- HL
- Marked features
- Function
Test conditions and notes11
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 3. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 4. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 5. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 6. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 8. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 9. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 10. Tolerance : includes set up tolerance, line regulation and load regulation.
- 11. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
Technical drawings
Typical applications
- LED panel lighting
- LED downlight
- LED decorative lighting
- Industrial lighting
- Sign board and back light
- LED strip lighting(C.V Dimming)
- Agricultural lighting(C.V Dimming)
- Poultry lighting (C.V Dimming)
- Type “HL” for use in Class I, Division 2 hazardous (Classified) location
Downloads
Certificates5
Test reports1
FAQ
Is the NPF-200-48 rated for outdoor or wet-location use?
Yes. The NPF-200-48 is IP67 rated and has a case temperature (Tcase) range of -40°C to +85°C. These characteristics make it appropriate for installation inside outdoor luminaires, tunnel lighting fixtures, and industrial enclosures that experience moisture or temperature extremes.
What high-power 48V LED applications suit the NPF-200-48?
The NPF-200-48 delivers 48V DC at 4.17A (200W) in constant-current mode. It suits 48V LED modules in commercial outdoor area lighting, large-format industrial high-bays, stadium perimeter lighting, and transportation infrastructure lighting where 200W of 48V drive capacity is needed.
How does the NPF-200-48 compare to the NPF-200-54?
Both share IP67, the 195.0 × 68.0 × 39.5 mm housing, 1.03 kg weight, and 100–305VAC input. NPF-200-48 outputs 48V at 4.17A (200W); NPF-200-54 outputs 54V at 3.71A (200W). The main difference is the output voltage and current; select based on your LED module's rated voltage.
Does the NPF-200-48 have a protective earth terminal?
No. The NPF-200-48 has a two-conductor AC input cable — AC/L (brown) and AC/N (blue) — and no FG (frame ground) terminal. Only the input and the Vo+/Vo- output wires need to be connected, which keeps cabling simple.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.