Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NGE90I48-P1J is the 48V output model of this series: rated current 1.875A, rated power 90W, typical efficiency 92%.
NGE90 is a highly reliable, 90W wall-mounted style single-output green adaptor series, which is compact and convenient for carry. This product is equipped with 7 types of interchangeable AC plug (European, USA,U.K. ,Australian, China, Korea and India type) that makes it very suitable for travel use.NGE90 is a Class Ⅱ power unit (no FG), accepting the input range from 80VAC to 264VAC that it can satisfy the demands for various types of electrical devices. With the working efficiency up to 92% and the extremely low no-load power consumption below 0.1W, NGE90 is compliant with the latest USA energy regulation EISA 2007/DoE, Canada NRCan,Australia and New Zealand MEPS , Korea KMEPS, EU ErP and CoC version 5. The supreme feature allows the adaptor to save the energy when it is under either the operating mode or the standby mode. The entire series is approved for ITE, medical, household and industrial application safety regulations; moreover, it adopts the 94V-0 flame retardant plastic case that it can effectively prevent users from electric hazard.
Features
- MEAN WELL Patent Application Number: 202330347779.4
- Interchangeable AC plugs (I-Type)
- Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1,Industrial 61558-1/-2-16)
- 80~264Vac Universal AC input
- Ultra slim(30mm)
- No load power consumption< 0.1W
- Energy efficiency Level Ⅵ
- Class Ⅱ power (no earth pin)
- Protections: Short circuit / Overload / Over voltage
- Extremely low leakage current <100uA
- -30℃~+70℃ wide range working temperature
- Various DC plug quick adaptor accessory available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGENote.2
- 48V
- RATED CURRENT
- 1.875A
- CURRENT RANGE
- 0 ~ 1.875A
- RATED POWER
- 90W
- RIPPLE & NOISE (max.)Note.3
- 240mVp-p
- VOLTAGE TOLERANCENote.4
- ±3.0%
- LINE REGULATIONNote.5
- ±1.0%
- LOAD REGULATIONNote.6
- ±2.0%
- SETUP, RISE, HOLD UP TIME
- 1000ms, 60ms, 30ms / 230Vac 1000ms, 60ms, 10ms / 115Vac at full load
INPUT
- VOLTAGE RANGENote.7
- 80 ~ 264Vac 113 ~ 370Vdc
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 92%
- AC CURRENT
- 1.8A / 115Vac 0.9A / 230Vac
- INRUSH CURRENT (max.)
- COLD START 50A / 115Vac 100A / 230Vac
- LEAKAGE CURRENT (max.)
- Touch current < 100uA (rms) @264Vac
PROTECTION
- OVERLOAD
- 105% ~ 160% rated output power Protection type : 12~24V Hiccup mode, recovers automatically after fault condition is removed. 48~55V Shut down and latch off o/p voltage, re-power on to recover.
- OVER VOLTAGE
- 52.8 ~ 64.8 Protection type : Shout donw O/P vlotage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 45℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
- IP rating
- IP21
SAFETY & EMC
- SAFETY STANDARDSNote.8
- CB IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16, IEC60335-1; UL UL62368-1, CSA C22.2 NO. 62368-1, ANSI/AAMI ES60601-1/-1-11(3.2 Version), CAN/CSA-C22.2 NO.60601-1/-1-11; ANSI/AAMI ES60601-1-11, CAN/CSA-C22.2 NO.60601-1-11(for U Type only) DEKRA BS EN/EN62368-1, BS EN/EN60601-1/-1-11, BS EN/EN61558-1/-2-16, BS EN/EN60335-1; PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1, AS/NZS 61558.1/.2.16; EAC TPTC004; CCC GB4943.1 approved. KC KC62368-1; BIS IS13252(part1):2010/IEC60950-1:2005. (Please refer to next page for more details)
- WITHSTAND VOLTAGE
- I/P-O/P:4000Vac
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted emission BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 , CNS15936, GB/T 9254.1-2021, KS C 9832 Class B Radiated emission BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 , CNS15936, GB/T 9254.1-2021, KS C 9832 Class B Harmonic current BS EN/EN61000-3-2 Class A - EMC IMMUNITY
-
BS EN/EN55035(CISPR35), BS EN/EN60601-1-2(IEC60601-1-2),KS C 9835
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 4, 15KV air; Level 4,8KV contact RF field susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT bursts BS EN/EN61000-4-4 Level 3, 2KV Surge susceptibility BS EN/EN61000-4-5 Level 3, 1KV/L-N Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V Magnetic field immunity BS EN/EN61000-4-8 Level 2, 3A/m Voltage dips , interruption BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 605.3 Khrs min. MIL-HDBK-217F (25℃) 5120.6 Khrs min. Telcordia TR/SR-332(Bellcore) (25℃)
- DIMENSION
- 62*30*85.5mm (L*W*H)
- PACKING MAIN BODY
- 217g; 54pcs/ 13.2Kg / 0.93CUFT for NGE90Ixx/Uxx-P1J 231g; 42pcs/ 11.6Kg / 1.13CUFT for NGE90Exx-P1J
- PACKING AC PLUGS
- Refer to Page 3
DC OUTPUT CONNECTOR
- PLUG
- See page 6~7 ; Other type available by customer requested
- CABLE
- See page 6~7 ; Other type available by customer requested
Test conditions and notes9
- 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
- 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
- 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μF & 47μF capacitor.
- 4.Tolerance: includes set up tolerance, line regulation, load regulation.
- 5.Line regulation is measured from low line to high line at rated load.
- 6.Load regulation is measured from 0% to 100% rated load
- 7.Derating may be needed under low input voltage. Please check the derating curve for more details.
- 8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9.Design meet US DoE Level VII (from Docket number EERE-2020-BT-STD-0006).
Technical drawings
Typical applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments
- Power sourcing equipment of PoE
- Medical devices
- Household devices
Downloads
Datasheet1
FAQ
What output does the Mean Well NGE90I48-P1J provide?
This model is a 90W AC-DC wall-mounted adaptor with a 48V DC output rated at 1.875A. It is designed for applications that require a regulated 48V supply within that power range.
What makes the NGE90I48-P1J suitable for international or multi-region use?
The NGE90I48-P1J uses interchangeable AC plugs and supports universal AC input from 80 to 264VAC. It also carries approvals across multiple standards and regions, which makes it a practical option for OEM and export-focused projects.
Is this adaptor intended for energy-efficient equipment?
Yes. This model meets Energy Efficiency Level VI and has very low no-load power consumption of less than 0.075W. That makes it a strong choice for equipment where standby power performance matters.
Can the NGE90I48-P1J be used in demanding temperature conditions?
It is rated for operation from -30°C to +70°C, giving it a wide working temperature range for industrial and commercial environments. Buyers should still confirm that the full application stays within the product's published operating conditions.
What protection features are included in this power adaptor?
The NGE90I48-P1J includes short circuit, overload, and over voltage protection. For the 48V version, overload protection uses shut down and latch-off behavior, with recovery after re-powering once the fault condition is cleared.
What types of equipment is this model commonly considered for?
Because it provides 48V DC at up to 90W, this adaptor is typically considered for professional, industrial, ITE, household, and certain medical-related equipment that matches those electrical requirements. It is especially relevant for B2B buyers needing a compact external power source with broad safety certifications.
How compact is the Mean Well NGE90I48-P1J?
This adaptor has a slim profile and measures 62 x 30 x 85.5 mm. Its ultra-slim 28 mm form factor can help when space around the outlet or mounted equipment is limited.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.