Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NGE65I18-P1J is the 18V output model of this series: rated current 3.62A, rated power 65.1W, typical efficiency 91%.
NGE65 is a highly reliable, 65W wall-mounted style single-output green adaptor series, which is compact and convient for carry. This product is equipped with 7 types of interchangeable AC plug (European, USA,U.K. ,Australian, China, Korea and India type) that makes it very suitable for travel use.NGE65 is a Class Ⅱ power unit (no FG), accepting the input range from 80VAC to 264VAC that it can satisfy the demands for various types of electrical devices. With the working efficiency up to 92% and the extremely low no-load power consumption below 0.075W, NGE65 is compliant with the latest USA energy regulation EISA 2007/DoE, Canada NRCan,Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC version 5. The superme feature allows the adaptor to save the energy when it is under either the operating mode or the standby mode. The entire series is approved for ITE, medical, household and industrial applia nce safety regulations; moreover, it adopts the 94V-0 flame retar dant plastic case that it can effectively prevent users from electric haz ard.
Features
- MEAN WELL Patent Application Number: 202330347779.4
- Interchangeable AC plugs (I-Type)
- Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1,Industrial 61558-1/-2-16)
- 80~264Vac Universal AC input
- Ultra slim(30mm)
- No load power consumption< 0.075W
- Energy efficiency Level Ⅵ
- Class Ⅱ power (no earth pin)
- Protections: Short circuit / Overload / Over voltage / Pass LPS
- Extremely low leakage current <100uA
- -30℃~+70℃ wide range working temperature
- Various DC plug quick adaptor accessory available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGENote.2
- 18V
- RATED CURRENT
- 3.62A
- CURRENT RANGE
- 0 ~ 3.62A
- RATED POWER
- 65.1W
- RIPPLE & NOISE (max.)Note.3
- 180mVp-p
- VOLTAGE TOLERANCENote.4
- ±3.0%
- LINE REGULATIONNote.5
- ±1.0%
- LOAD REGULATIONNote.6
- ±3.0%
- SETUP, RISE, HOLD UP TIME
- 1500ms, 50ms, 30ms / 230Vac 3000ms, 50ms, 10ms / 115Vac at full load
INPUT
- VOLTAGE RANGENote.7
- 80 ~ 264Vac 113 ~ 370Vdc
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 91%
- AC CURRENT
- 1.5A / 115Vac 0.8A / 230Vac
- INRUSH CURRENT (max.)
- COLD START 50A / 115Vac 100A / 230Vac
- LEAKAGE CURRENT (max.)
- Touch current < 100uA (rms) @264Vac
PROTECTION
- OVERLOAD
- 110% ~ 150% rated output power Protection type : 5~24V Hiccup mode, recovers automatically after fault condition is removed. 48V Shut down and latch off o/p voltage, re-power on to recover.
- OVER VOLTAGE
- 110% ~ 140% rated output voltage Protection type : Clamp by zener diode
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
- IP rating
- IP21
SAFETY & EMC
- SAFETY STANDARDSNote.8
- CB IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16, IEC60335-1; UL UL62368-1, CSA C22.2 NO. 62368-1, ANSI/AAMI ES60601-1/-1-11(3.2 Version), CAN/CSA-C22.2 NO.60601-1/-1-11; ANSI/AAMI ES60601-1-11, CAN/CSA-C22.2 NO.60601-1-11(for U Type only) DEKRA BS EN/EN62368-1, BS EN/EN60601-1/-1-11, BS EN/EN61558-1/-2-16, BS EN/EN60335-1; PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1, AS/NZS 6 1558 .1/ .2 . 16 ; EAC TPTC004; CCC GB4943.1 approved . KC KC62368-1; BIS IS13252(part1):2010/IEC60950-1:2005. (Please refer to next page for more details)
- WITHSTAND VOLTAGE
- I/P-O/P:4000Vac
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted emission BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 , CNS15936, GB/T 9254.1-2021, KS C 9832 Class B Radiated emission BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 , CNS15936, GB/T 9254.1-2021, KS C 9832 Class B Harmonic current BS EN/EN61000-3-2 Class A - EMC IMMUNITY
-
BS EN/EN55035(CISPR35), BS EN/EN60601-1-2(IEC60601-1-2),KS C 9835
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 4, 15KV air; Level 4,8KV contact RF field susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT bursts BS EN/EN61000-4-4 Level 3, 2KV Surge susceptibility BS EN/EN61000-4-5 Level 3, 1KV/L-N Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V Magnetic field immunity BS EN/EN61000-4-8 Level 2, 3A/m Voltage dips , interruption BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 682.2 Khrs min. MIL-HDBK-217F (25℃) 5852.4 Khrs min. Telcordia TR/SR-332(Bellcore) (25℃)
- DIMENSION
- 62*30*65mm (L*W*H)
- PACKING MAIN BODY
- 196g; 60pcs/ 13.4Kg / 0.94CUFT for NGE65Ixx/Uxx-P1J 211g; 45pcs/ 11.4Kg / 1.06CUFT for NGE65Exx-P1J
- PACKING AC PLUGS
- Refer to Page 3
DC OUTPUT CONNECTOR
- PLUG
- See page 6~7 ; Other type available by customer requested
- CABLE
- See page 6~7 ; Other type available by customer requested
Test conditions and notes10
- 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
- 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
- 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μF & 47μF capacitor.
- 4.Tolerance: includes set up tolerance, line regulation, load regulation.
- 5.Line regulation is measured from low line to high line at rated load.
- 6.Load regulation is measured from 0% to 100% rated load
- 7.Derating may be needed under low input voltage. Please check the derating curve for more details.
- 8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9.Test harmonic current at 85% load.
- 10.Design meet US DoE Level VII (from Docket number EERE-2020-BT-STD-0006).
Technical drawings
Typical applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments
- Medical devices
- Household devices
Downloads
Datasheet1
FAQ
What are the output specifications of the Mean Well NGE65I18-P1J?
The NGE65I18-P1J is rated for 18V DC output at up to 3.62A, with a maximum power rating of 65.1W. This makes it suitable for equipment that specifically requires a regulated 18V supply within that power range.
What types of equipment is this 18V wall adaptor typically used for?
This model is generally suited to business and industrial equipment that needs a compact 18V external AC-DC power adaptor up to 65.1W. Common use cases include electronics, control devices, and other OEM equipment where a wall-mounted adaptor with regulated output is preferred. Final suitability depends on the device matching the 18V DC requirement and current draw.
Does the NGE65I18-P1J support different plug formats for different markets?
Yes. This model is part of Mean Well's interchangeable-plug adaptor range, which is designed for use with different AC plug formats. It also supports a universal 80 to 264VAC input range, making it practical for multi-region deployment where the correct plug accessory is used.
Is this adaptor a good choice for energy-efficient or always-on equipment?
It is designed for high efficiency, with Energy Efficiency Level VI compliance and no-load power consumption below 0.075W. That makes the NGE65I18-P1J a strong option for systems that spend long periods powered but lightly loaded or in standby.
Can this power adaptor operate in demanding temperature conditions?
The specified operating temperature range is -30C to +70C, which is wider than many standard commercial plug-in adaptors. That makes it suitable for a broader range of indoor and sheltered equipment environments, provided the rest of the system is rated for similar conditions.
What safety and protection features does the NGE65I18-P1J include?
This model includes short circuit, overload, and over-voltage protection, and it is a Class II power unit with no earth pin. It also carries broad safety approvals across ITE, medical, household, and industrial standards, including IEC62368-1, IEC60601-1, IEC60335-1, and IEC61558-1/-2-16.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.