Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
NGE18I12-P1J is the 12V output model of this series: rated current 1.5A, rated power 18W, typical efficiency 87%.
NGE18 is a highly reliable, 18W wall-mounted style single-output green adaptor series, which is compact and convient for carry. This product is equipped with 7 types of interchangeable AC plug (European, USA,U.K. ,Australian, China, Korea and India type) that makes it very suitable for travel use. NGE18 is a Class Ⅱ power unit (no FG), accepting the input range from 80VAC to 264VAC that it can satisfy the demands for various types of electrical devices. With the working efficiency up to 88% and the extremely low no-load power consumption below 0.075W, NGE18 is compliant with the latest USA energy regulation EISA 2007/DoE, Canada NRCan,Australia and New Zealand MEPS, Korea KMEPS, EU ErP and CoC version5. The superme feature allows the adaptor to save the energy when it is under either the operating mode or the standby mode. The entire series is approved for ITE, medical household and industrial applianc e safety regulations; moreover, it adopts the 94V-0 flame retar dant plastic case that it can effectively prevent users from electric hazard.
Features
- MEAN WELL Patent Application Number: 202330347779.4
- Interchangeable AC plugs (I-Type)
- Global certificates in multi-fields (ITE 62368-1, Medical 60601-1, Household 60335-1,Industrial 61558-1/-2-16)
- 80~264Vac Universal AC input
- Ultra slim(28mm)
- No load power consumption< 0.075W
- Energy efficiency Level Ⅵ
- Class Ⅱ power (no earth pin)
- Protections: Short circuit / Overload / Over voltage
- Pass LPS
- Extremely low leakage current <100uA
- -30℃~+70℃ wide range working temperature
- Various DC plug quick adaptor accessory available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGENote.2
- 12V
- RATED CURRENT
- 1.5A
- CURRENT RANGE
- 0 ~ 1.5A
- RATED POWER
- 18W
- RIPPLE & NOISE (max.)Note.3
- 120mVp-p
- VOLTAGE TOLERANCENote.4
- ±3.0%
- LINE REGULATIONNote.5
- ±1.0%
- LOAD REGULATIONNote.6
- ±3.0%
- SETUP, RISE, HOLD UP TIME
- 1500ms, 30ms, 30ms / 230Vac 3000ms, 30ms, 10ms / 115Vac at full load
INPUT
- VOLTAGE RANGENote.7
- 80 ~ 264Vac 113 ~ 370Vdc
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 87%
- AC CURRENT
- 0.4A / 115Vac 0.25A / 230Vac
- INRUSH CURRENT (max.)
- COLD START 40A / 115Vac 80A / 230Vac
- LEAKAGE CURRENT (max.)
- Touch current < 100uA (rms) @264Vac
PROTECTION
- OVERLOAD
- 110% ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 115% ~ 140% rated output voltage Protection type : Clamp by zener diode
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -20 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 45℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
- IP rating
- IP21
SAFETY & EMC
- SAFETY STANDARDSNote.8
- CB IEC62368-1, IEC60601-1/-1-11, IEC61558-1/-2-16, IEC60335-1; UL UL62368-1, CSA C22.2 NO. 62368-1, ANSI/AAMI ES60601-1/-1-11(3.2 Version), CAN/CSA-C22.2 NO.60601-1/-1-11; ANSI/AAMI ES60601-1-11, CAN/CSA-C22.2 NO.60601-1-11(for U Type only) DEKRA BS EN/EN62368-1, BS EN/EN60601-1/-1-11, BS EN/EN61558-1/-2-16, BS EN/EN60335-1; PSE J62368-1; BSMI CNS15598-1; RCM AS/NZS 62368.1, AS/NZS 61558.1/.2.16; EAC TPTC004; CCC GB4943.1 approved. KC KC62368-1; BIS IS13252 (part1):2010/IEC60950-1:2005. (Please refer to next page for more details)
- WITHSTAND VOLTAGE
- I/P-O/P:4000Vac
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted emission BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 , CNS15936, GB/T 9254.1-2021, KS C 9832 Class B Radiated emission BS EN/EN55032(CISPR32)/EN55011 , FCC Part15 , CNS15936, GB/T 9254.1-2021, KS C 9832 Class B Harmonic current BS EN/EN61000-3-2 Class A - EMC IMMUNITY
-
BS EN/EN55035(CISPR35), BS EN/EN60601-1-2(IEC60601-1-2),KS C 9835
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 4, 15KV air; Level 4,8KV contact RF field susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT bursts BS EN/EN61000-4-4 Level 3, 2KV Surge susceptibility BS EN/EN61000-4-5 Level 3, 1KV/L-N Conducted susceptibility BS EN/EN61000-4-6 Level 2, 3V Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m Voltage dips , interruption BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 1272.8 Khrs min. MIL-HDBK-217F (25℃) 7192.4 Khrs min. Telcordia TR/SR-332(Bellcore) (25℃)
- DIMENSION
- 48*28*55mm (L*W*H)
- PACKING MAIN BODY
- 112g; 96pcs/ 12.6Kg / 1.02CUFT for NGE18Ixx/Uxx-P1J 127g; 72pcs/ 11.2Kg / 1.36CUFT for NGE18Exx-P1J
- PACKING AC PLUGS
- Refer to Page 3
DC OUTPUT CONNECTOR
- PLUG
- See page 6~7 ; Other type available by customer requested
- CABLE
- See page 6~7 ; Other type available by customer requested
Test conditions and notes9
- 1.All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
- 2.DC voltage: The output voltage set at point measure by plug terminal & 50% load.
- 3.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μF & 47μF capacitor.
- 4.Tolerance: includes set up tolerance, line regulation, load regulation.
- 5.Line regulation is measured from low line to high line at rated load.
- 6.Load regulation is measured from 0% to 100% rated load
- 7.Derating may be needed under low input voltage. Please check the derating curve for more details.
- 8.The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9.Design meet US DoE Level VII (from Docket number EERE-2020-BT-STD-0006).
Technical drawings
Typical applications
- Consumer electronic devices
- Telecommunication devices
- Office facilities
- Industrial equipments
- Medical devices
- Household devices
Downloads
Datasheet1
FAQ
What are the main output specifications of the Mean Well NGE18I12-P1J?
This model is a 18W AC-DC wall-mounted adaptor with a regulated 12V DC output. It is rated for up to 1.5A current, which makes it suitable for equipment that requires a 12V supply within that power range.
What makes the NGE18I12-P1J different from a standard fixed-plug wall adaptor?
The NGE18I12-P1J uses an interchangeable plug design rather than a fixed regional plug format. It is also built with very low no-load power consumption under 0.075W, Energy Efficiency Level VI performance, and a slim 28mm profile.
Is this power adaptor suitable for international or multi-region use?
Yes, this model supports universal AC input from 80 to 264VAC, which makes it appropriate for use across many regional power systems. Its interchangeable AC plug format also helps buyers standardize one adaptor platform for different markets.
What types of equipment is the NGE18I12-P1J commonly used with?
It is typically used for devices that need a 12V DC wall adaptor up to 1.5A. Typical B2B use cases include commercial, industrial, household, medical, and ITE equipment where buyers need a compact external power supply with broad certification coverage.
Can this adaptor be used in demanding temperature conditions?
Yes, the NGE18I12-P1J is rated for operation from -30°C to +70°C. That wide working range makes it a stronger fit for equipment used in colder or warmer environments than many basic indoor-only adaptors.
What protection and safety features are included in this model?
This adaptor includes short circuit, overload, and over-voltage protection. It is a Class II power unit with no earth pin, passes LPS, and is listed with multiple safety standards including IEC 62368-1, IEC 60601-1, IEC 60335-1, and IEC 61558-1/-2-16.
How do I know if the NGE18I12-P1J is compatible with my device?
The key compatibility checks are whether your equipment requires 12V DC and draws no more than 1.5A. Buyers should also confirm that the required plug format and any DC plug adapter accessory match their device requirements, since this series supports interchangeable AC plugs and optional DC plug quick adapters.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other NGE18 Models
1 other model| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well NGE18U09-P1J AC-DC Wall-mounted Green Adaptor - US Plug - 18W 9V 2A | 18W | 9V | 2A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.