Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
LPF-60-42 is the 42V output model of this series: rated current 1.43A, rated power 60.06W, typical efficiency 90%.
LPF-60 series is a 60W AC/DC LED driver featuring the dual modes constant voltage and constant current output. LPF-60 operates from 90~305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 90%, with the fanless design, the entire series is able to operate for -40℃ ~ +80℃ case temperature under free air convection. The entire series is rated with IP67 ingress protection level and is suitable to work for a variety of applications at dry, damp or wet locations.
Features
- Constant Voltage + Constant Current mode output
- Plastic housing with Class II design
- Built-in active PFC function
- Class 2 power unit
- Fully encapsulated with IP67 level
- Typical lifetime>50000 hours
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 42V
- CONSTANT CURRENT REGIONNote.2
- 25.2 ~ 42V
- RATED CURRENT
- 1.43A
- RATED POWERNote.5
- 60.06W
- RIPPLE & NOISE (max.)Note.3
- 250mVp-p
- VOLTAGE TOLERANCENote.4
- ±4.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 1000ms, 80ms / 115VAC 500ms, 80ms / 230VAC
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
- EFFICIENCY (Typ.)
- 90%
- AC CURRENT
- 0.8A / 115VAC 0.4A / 230VAC 0.32A/277VAC
- INRUSH CURRENT(Typ.)
- COLD START 55A(twidth=270μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 8 units (circuit breaker of type B) / 14 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVER CURRENT
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 46 ~ 54V
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- Tcase=-40 ~ +80℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
- MAX. CASE TEMP.
- Tcase=+80℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.8
- UL8750, CSA C22.2 No. 250.0-08, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, IP67, J61347-1, J61347-2-13, BIS IS15885 (for 24V only) , EAC TP TC 004, GB/T19510.1,GB/T19510. 213 approved ; design refer to UL60950-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSIONNote.8
- Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load≧60%) ; BS EN/EN61000-3-3, GB/T 17743 , GB17625.1, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV), EAC TP TC 020
OTHERS
- MTBF
- 3786.9K hrs min. Telcordia SR-332 (Bellcore) ; 440.6Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 162.5*43*32mm (L*W*H)
- PACKING
- 0.45Kg; 32pcs/15.4Kg/0.93CUFT
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Please refer to "DRIVING METHODS OF LED MODULE".
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 4. Tolerance : includes set up tolerance, line regulation and load regulation.
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- 9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Technical drawings
Typical applications
- LED panel lighting
- LED downlight
- LED decorative lighting
- LED tunnel lighting
- Moving sign
Downloads
Certificates5
Test reports1
Catalogues1
FAQ
Can I use the LPF-60-42 for a 42V LED lighting load?
Yes, if the 42V lighting product does not exceed 60.06W or 1.43A. The driver supplies 42V constant voltage and has a 25.2-42V constant current region, so the load needs to be compatible with one of those modes.
Is this driver appropriate for 42V outdoor sign or display lighting?
It can be appropriate for 42V sign or display lighting when the modules are 42V constant voltage or 25.2-42V constant current types and remain within the 60.06W, 1.43A limit. Its IP67 rating is relevant for outdoor conditions where water exposure is possible.
Can the LPF-60-42 be used for exterior architectural lighting fixtures?
Yes, provided the fixture's LED engine is designed for 42V constant voltage or constant current input within the 25.2-42V range. The driver also has a Tcase working range of -40°C to +80°C (with load derating at higher temperatures), which helps in exposed architectural environments.
Is the LPF-60-42 suitable for wet or outdoor environments?
Yes, it has an IP67 waterproof rating, so it is intended for outdoor and wet-location use. That rating is the key specification for resistance to water and dust exposure around the driver body.
How much 42V LED strip can this driver run?
The maximum output is 60.06W total at 42V, with a maximum current of 1.43A. To estimate strip length, divide 60.06W by the strip's watts per meter, and check your strip rated power per meter before choosing a final run length.
What other LPF-60 models are available besides the 42V version?
Other LPF-60 outputs are 12V 5A 60W, 15V 4A 60W, 20V 3A 60W, 24V 2.5A 60W, 30V 2A 60W, 36V 1.67A 60.12W, 48V 1.25A 60W, and 54V 1.12A 60.48W, alongside this 42V 1.43A 60.06W model. All share the same 90-305VAC input, IP67 rating and 162.5 x 43 x 32 mm case.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.