Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
LPF-16-20 is the 20V output model of this series: rated current 0.8A, rated power 16W, typical efficiency 86%.
LPF-16 series is a 16W AC/DC LED driver featuring the dual modes constant voltage and constant current output. LPF-16 operates from 90~305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the efficiency up to 86%, with the fanless design, the entire series is able to operate for -35℃ ~ +70℃ case temperature under free air convection. The entire series is suitable to work for a variety of applications at dry or damp locations and the optional models with IP67 rating is able to further work at wet locations.
Features
- Constant Voltage + Constant Current mode output
- Plastic housing with Class II design
- Built-in active PFC function
- Class 2 power unit
- Standard type with IP30 level, optional IP67 with fully encapsulated
- Typical lifetime>50000 hours
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 20V
- CONSTANT CURRENT REGIONNote.2
- 11 ~ 20V
- RATED CURRENT
- 0.8A
- RATED POWERNote.5
- 16W
- RIPPLE & NOISE (max.)Note.3
- 150mVp-p
- VOLTAGE TOLERANCENote.4
- ±4.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIMENote.6
- 1500ms, 80ms / 115VAC 500ms, 80ms / 230VAC
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms /115VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20%(@load≧60%/115VC,230VAC; @load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
- EFFICIENCY (Typ.)
- 86%
- AC CURRENT
- 0.4A / 115VAC 0.25A / 230VAC 0.2A/277VAC
- INRUSH CURRENT(Typ.)
- COLD START 45A(twidth=200μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 14 units (circuit breaker of type B) / 24 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVER CURRENT
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 23 ~ 27V Shut down and latch off o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- Tcase=-35 ~ +70℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
- MAX. CASE TEMP.
- Tcase=+70℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.8
- UL8750, CSA C22.2 No. 250.0-08; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent , BS EN/EN62384,J61347-1, J61347-2-13,EAC TP TC 004,GB/T19510.1,GB/T19510. 213 approved,IP67 (optional) ; Design refer to UL60950-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSIONNote.8
- Compliance to BS EN/EN55015,BS EN/EN61000-3-2 Class C (@load≧50%) ; BS EN/EN61000-3-3,GB/T 17743 , GB17625.1, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, light industry level (surge immunity Line-Line 2KV),EAC TP TC 020
OTHERS
- MTBF
- 3572.8K hrs min. Telcordia SR-332 (Bellcore) ; 427.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 148*40*32mm (L*W*H)
- PACKING
- 0.21Kg; 40pcs/9.4Kg/1.02CUFT
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Please refer to "DRIVING METHODS OF LED MODULE".
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 4. Tolerance : includes set up tolerance, line regulation and load regulation.
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- 9. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 70℃ or less.
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Technical drawings
Typical applications
- LED downlight
- LED spotlight
- LED decorative lighting
- LED tunnel lighting
Downloads
Certificates5
Test reports1
Catalogues1
FAQ
Can I use the LPF-16-20 for a 20V LED signage module?
Yes, if the signage module is designed for 20V operation and does not draw more than 0.8A or 16W. This model works in constant voltage mode at 20V or regulates current across an 11-20V constant current region, so the load has to match that specification.
Is this a good fit for a compact 20V display or cabinet light?
It can be, provided the light engine is specified for a 20V driver output and stays within 16W and 0.8A. Note that the sheet lists the standard unit as IP30, with IP67 only as an option, so as standard it should be kept away from dust and water.
Can the LPF-16-20 be used for a short 20V LED strip in a damp area?
Electrically it can drive a 20V strip drawing up to 0.8A, in constant voltage mode or within the 11-20V constant current region. However, the sheet lists the standard unit as IP30, with IP67 only as an option, so this version is not rated for damp or outdoor environments.
What LED strip length can this 20V driver handle?
The power limit is 16W, so the estimated strip length is 16W divided by your strip's rated watts per meter. Check your strip rated power per meter and make sure the strip is compatible with a 20V output limited to 0.8A before sizing the run.
Can this driver stay outside year-round?
No, not as standard. The sheet shows the standard unit as IP30, with IP67 listed only as an option, so it is not rated for permanent outdoor installation. Its working case temperature (Tcase) range is -35°C to +70°C.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.