Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRP-200-12 is the 12V output model of this series: rated current 16.7A, rated power 200.4W, typical efficiency 88%.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- 1U low profile 38mm
- Built-in remote sense function
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- RATED CURRENT
- 16.7A
- CURRENT RANGE
- 0 ~ 16.7A
- RATED POWER
- 200.4W
- RIPPLE & NOISE (max.)Note.2
- 120mVp-p
- VOLTAGE ADJ. RANGE
- 10.2 ~ 13.8V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.3%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC 2500ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT (Typ.)
- 2.1A/115VAC 1.1A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1.2mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 14.4 ~ 16.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035,heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 1830.6K hrs min. Telcordia SR-332 (Bellcore) ; 209.5K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 199*98*38mm (L*W*H)
- PACKING
- 0.77Kg; 18pcs/14.9Kg/0.87CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Datasheet1
Certificates4
Test reports1
Catalogues1
FAQ
Can I use the HRP-200-12 for a 12V industrial automation system?
Yes, if the automation load needs a constant 12V output and stays within 200.4W and 16.7A. That makes it relevant for 12V control, monitoring, and support loads in industrial equipment. The 85-264VAC input is also useful where site AC power may vary.
Is the HRP-200-12 suitable for 12V CCTV or low-voltage security hardware?
It can be used for 12V security hardware when the combined load does not exceed 16.7A or 200.4W. This model is constant voltage, so it is intended for equipment that specifically expects a 12V DC supply. Its 16.7A rating suits higher-current 12V systems.
Can this model power a 12V embedded or mobile-style computing platform?
It can fit embedded computing, edge processing, or IT hardware that is designed for a 12V DC input and remains within 200.4W. The built-in PFC and 88% typical efficiency can be useful where power quality and heat matter. Its size of 199 x 98 x 38 mm also helps define whether it fits the equipment envelope.
How does the HRP-200-12 compare with other 200-series HRP models?
The 200-series options are 3.3V 132W 40A, 5V 175W 35A, 7.5V 200.3W 26.7A, 12V 200.4W 16.7A, 15V 201W 13.4A, 24V 201.6W 8.4A, 36V 205.2W 5.7A, and 48V 206.4W 4.3A. The main differences are output voltage, available current, and total wattage. This model is the 12V version and provides 16.7A.
Can the HRP-200-12 be used in cold or hot equipment environments?
The specified operating temperature range is -40°C to +70°C, which supports use in very cold or hot equipment locations. No IP rating is listed in the provided specs, so environmental sealing is not defined here. That means indoor or protected-enclosure use is the safer assumption unless the final system provides the needed protection.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.







