Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HRP-150-15 is the 15V output model of this series: rated current 10A, rated power 150W, typical efficiency 88%.
Features
- Universal AC input / Full range
- Built-in active PFC function, PF>0.95
- High efficiency up to 89%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Cooling by free air convection
- Built-in constant current limiting circuit
- 1U low profile 38mm
- Built-in remote sense function
- 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- RATED CURRENT
- 10A
- CURRENT RANGE
- 0 ~ 10A
- RATED POWER
- 150W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 13.5 ~ 18V
- VOLTAGE TOLERANCENote.3
- ±1.5%
- LINE REGULATION
- ±0.3%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 3000ms, 50ms/230VAC 3000ms, 50ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.99/115VAC at full load
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT (Typ.)
- 1.7A/115VAC 0.9A/230VAC
- INRUSH CURRENT (Typ.)
- 35A/115VAC 70A/230VAC
- LEAKAGE CURRENT
- <1mA / 240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 18.8 ~ 21.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -50 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.04%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1,TUV BS EN/EN62368-1, AS/NZS62368.1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11,BS EN/EN55035 , BS EN/ EN61000-6-2 ,heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 1742.7K hrs min. Telcordia SR-332 (Bellcore) ; 238.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 159*97*38mm (L*W*H)
- PACKING
- 0.61Kg; 24pcs/15.6Kg/0.9CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. Strongly recommended that external output capacitance should not exceed 5000uF. (Only for: HRP-150-3.3/-5/-7.5/-12/-15)
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
FAQ
Can I use the HRP-150-15 for a 15V industrial control panel?
Yes, this model is a constant voltage 15V power supply rated for 150W and 10A. It fits 15V industrial control or automation loads that stay within that output range.
Is the HRP-150-15 suitable for 15V embedded test benches or lab fixtures?
It can be a fit for embedded benches or production fixtures that require a regulated 15V DC source. The unit provides up to 10A at 15V with universal 85-264VAC input.
Can this 15V power supply run multiple 15V automation devices from one source?
It is intended for 15V constant voltage loads with a total power draw up to 150W and total current up to 10A. For grouped automation devices, the combined demand needs to remain within those limits.
Is HRP-150-15 a good choice for 15V industrial electronics cabinets?
Yes, its 159 x 97 x 38 mm size and 0.61 kg weight make it suitable where a compact AC-DC supply is needed. The 15V, 10A output is aimed at industrial or embedded electronics that use a 15V DC bus.
Can the HRP-150-15 be used outdoors or in harsh temperature conditions?
Its operating temperature range is -40C to +70C, with output derating at higher temperatures per the derating curve. However, no IP rating is listed, so it is better suited to protected indoor enclosures or other installations where environmental sealing is handled separately.
How does HRP-150-15 compare with the other HRP-150 output options?
Within the HRP-150 family, the output options are 3.3V at 99W and 30A, 5V at 130W and 26A, 7.5V at 150W and 20A, 12V at 156W and 13A, 15V at 150W and 10A, 24V at 156W and 6.5A, 36V at 154.8W and 4.3A, and 48V at 158.4W and 3.3A. The main difference is the DC output voltage and corresponding current rating.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.