Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLN-40H-48A is the 48V output model of this series: rated current 0.84A, rated power 40.3W, typical efficiency 89%.
Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- OCP point adjustable through output cable or internal potentiometer
- Fully isolated plastic case with IP64 level
- Class 2 power unit
- Three in one dimming function (1~10Vdc or PWM signal or resistance)
- Suitable for LED lighting, Industrial Lighting and moving sign applications
- Compliance to worldwide safety regulations for lighting
- Suitable for dry / damp locations or outdoor application
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- CONSTANT CURRENT REGIONNote.4
- 28.8 ~ 48V
- RATED CURRENT
- 0.84A
- RATED POWER
- 40.3W
- RIPPLE & NOISE (max.)Note.2
- 300mVp-p
- VOLTAGE ADJ. RANGENote.6
- 44 ~ 53V
- CURRENT ADJ. RANGE
- Can be adjusted by internal potentiometer A type only
- CURRENT ADJ. RANGE
- 0.5 ~ 0.84A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.7
- 500ms, 80ms at full load 230VAC / 115VAC
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.98/115VAC, PF>0.95/230VAC, PF>0.92/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
- EFFICIENCY (Typ.)
- 89%
- AC CURRENT (Typ.)
- 0.43A / 115VAC 0.24A / 230VAC 0.23A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 50A(twidth=210μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 12 units (circuit breaker of type B) / 20 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 54 ~ 65V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +50℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 40℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750, CSA C22.2 No. 250.0-08 , BS EN/EN 61347-1, BS EN/EN 61347-2-13 independent, IP64, EAC TP TC 004 approved ; design refer to UL60950-1, BS EN/EN60335-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11; BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), EAC TP TC 020
OTHERS
- MTBF
- 3396.4K hrs min. Telcordia SR-332(Bellcore) ; 346.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 161*61.5*35mm (L*W*H)
- PACKING
- 0.35Kg;32pcs/12.2Kg/1.10CUFT
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 6. A type only.
- 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 8. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 11. This product is not suitable for LED lighting applications in China.(It is recommended to use the LPF/NPF/XLG/XLC/XLN series in China)
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Technical drawings
Downloads
FAQ
Can I use the HLN-40H-48A for 48V LED signage?
Yes, it can be used for 48V signage, either as a 48V constant-voltage supply or in constant-current mode for loads that operate within the 28.8-48V CC region. It supplies up to 0.84A with a maximum output of 40.3W, and signage is a typical application.
Is this driver suitable for 48V linear lighting fixtures?
It is suitable for 48V linear lighting fixtures that need up to 0.84A, whether they take a 48V constant-voltage supply or are driven directly within the 28.8-48V constant-current region. The fixture also needs to remain within the driver's 40.3W output limit.
Can the HLN-40H-48A power a 48V LED strip?
Yes, within its limits. The driver has a constant voltage + constant current characteristic, so it can run a 48V constant-voltage strip (output adjustable 44-53V) at up to 0.84A, or drive LEDs directly in constant-current mode within the 28.8-48V region. Keep the strip load within 40.3W.
Is the HLN-40H-48A okay for outdoor or washdown areas?
It is suitable for dust-exposed and splash-prone locations because the enclosure is rated IP64. That supports many sheltered outdoor uses, but IP64 covers splashing water rather than hose-down washdown or immersion, and the operating temperature range is -40°C to +50°C.
How do I calculate the maximum 48V LED strip length for this driver?
The driver's maximum output is 40.3W. To estimate length, divide 40.3W by the strip's rated power per meter, and check that the strip is a 48V product whose total current stays within 0.84A (or, for constant-current operation, within the 28.8-48V CC region).
What are the main output differences across the HLN-40H series?
The HLN-40H series spans 12V at 3.33A, 15V at 2.67A, 20V at 2A, 24V at 1.67A, 30V at 1.34A, 36V at 1.12A, 42V at 0.96A, 48V at 0.84A, and 54V at 0.75A. The HLN-40H-48A is the adjustable 48V version with 40.3W maximum output.