HLG-600H-36 is the 36V output model of this series: rated current 16.7A, rated power 601.2W, typical efficiency 95.5%. Type Blank: lo and Vo fixed (IP67).
HLG-600H series is a 600W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-600H operates from 90~305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 96%, with the fanless design, the entire series is able to operate for -40℃ ~ +90℃ case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-600H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
- Constant Voltage + Constant Current mode output
- Metal housing with class I design
- Standby power consumption <0.5W at remote off
- IP67 rating for indoor or outdoor installations
- Typical lifetime > 62000 hours
- 7 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 36V
- CONSTANT CURRENT REGIONNote.4
- 18 ~ 36V
- RATED CURRENT
- 16.7A
- RATED POWER
- 601.2W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 500ms, 80ms/ 115VAC, 230VAC
- HOLD UP TIME (Typ.)
- 15ms / 115VAC, 230VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.93/277VAC @ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20% (@ load≧50% /115VAC, 230VAC; @ load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
- EFFICIENCY (Typ.) 230VAC
- 95.5%
- EFFICIENCY (Typ.) 277VAC
- 95.5%
- AC CURRENT (Typ.)
- 7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 70A(twidth=1000μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- STANDBY POWER CONSUMPTION
- <0.5W at remote off
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 39.5 ~ 43.5V Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
FUNCTION
- REMOTE ON/OFF CONTROL
- Power on : "High" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit
- 5V STANDBY
- 5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
ENVIRONMENT
- WORKING TEMP.
- Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase= +90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 55℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC (Note 10)
- SAFETY STANDARDSNote.7
- UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, IP65 or IP67, J61347-1, J61347-2-13, GB/T19510.1,GB/T19510.213, EAC TP TC 004, AS/NZS 60950.1(by CB),KC61347-1, KC61347-2-13(except for AB type) approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSIONNote.7
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3, EAC TP TC 020; GB/T 17743,GB17625.1, KS C 9815, KS C 9547
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020; KS C 9815, KS C 9547
OTHERS
- MTBF
- 913.4K hrs min. Telcordia SR-332 (Bellcore) ; 76.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 280*144*48.5mm (L*W*H)
- PACKING
- 3.9Kg; 4pcs/16.6Kg/0.9CUFT
MODEL ENCODING
- A
- Io and Vo adjustable through built-in potentiometer; IP65
- B
- 3 in 1 dimming function (0~10VDC, 10V PWM signal and resistance); IP67
- AB
- lo and Vo adjustable through built-in potentiometer & 3 in 1 dimming function (0~10VDC,10V PWM signal and resistance); IP65
- Blank (this model)
- lo and Vo fixed; IP67
Test conditions and notes12
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The model certified for CCC(GB/T19510.1, GB/T19510.213, GB/T 17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
- 8. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 10. The driver is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
Technical drawings
Typical applications
- LED high-bay lighting
- Parking space lighting
- LED fishing lamp
- LED greenhouse lighting
- Type "HL" for use in ClassⅠ, Division 2 hazardous (Classified) location.
Downloads
Datasheet1
Certificates6
Catalogues1
FAQ
Can I use the HLG-600H-36 for large-scale 36V LED strip installations?
Yes. The HLG-600H-36 delivers 600W at 36V with up to 16.7A of output, which is enough to drive long runs of high-power 36V LED strips for commercial, retail, or architectural lighting. Its IP67 waterproof rating also allows outdoor placement without an additional enclosure.
Is the HLG-600H-36 suitable for powering 36V LED high-bay or warehouse lighting?
Yes. With 600W at 36V, it can drive multiple 36V LED high-bay fixtures wired in parallel, provided their combined load stays within 600W. The wide 90-305VAC input accommodates the varying mains voltages often found in industrial and warehouse facilities.
Can I power 36V LED grow lights with the HLG-600H-36?
Yes. The HLG-600H-36 provides 600W at 36V in constant-current mode with a CC voltage range of 18-36V, making it compatible with many 36V horticulture LED panels. Its 95.5% efficiency and fanless metal housing help manage heat, which is important in enclosed growing environments.
How many meters of 36V LED strip can the HLG-600H-36 power?
Divide 600W by your strip's wattage per meter. For example, a 36V strip rated at 12W/m would allow up to 50 meters (600W / 12W per meter = 50m). Check your strip's rated power per meter and keep the total load at or below 600W.
Can the HLG-600H-36 be mounted outdoors in direct weather exposure?
Yes. Its IP67 waterproof rating protects against dust ingress and temporary water immersion. Combined with a -40°C to +90°C case temperature (Tcase) range, it is designed for fully exposed outdoor installations including rooftops, building exteriors, and landscape applications.
What are the differences between the HLG-600H-36, 36A, 36AB, and 36B variants?
All four deliver 600W at 36V / 16.7A. The base HLG-600H-36 has fixed output and IP67 waterproof protection. The -36A adds a built-in potentiometer for output voltage and current adjustment (IP65). The -36AB adds both adjustment and 0-10V/PWM/resistance dimming (IP65). The -36B provides dimming input only while retaining IP67 waterproof rating.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.