Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLG-600H-30B is the 30V output model of this series: rated current 20A, rated power 600W, typical efficiency 95%.
HLG-600H series is a 600W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-600H operates from 90~305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 96%, with the fanless design, the entire series is able to operate for -40℃ ~ +90℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-600H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
- Constant Voltage + Constant Current mode output
- Metal housing with class I design
- Standby power consumption <0.5W at remote off
- IP67 / IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off)
- Typical lifetime > 62000 hours
- 7 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 30V
- CONSTANT CURRENT REGIONNote.4
- 15 ~ 30V
- RATED CURRENT
- 20A
- RATED POWER
- 600W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 25.5 ~ 31.5V
- CURRENT ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 10 ~ 20A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 500ms, 80ms/ 115VAC, 230VAC
- HOLD UP TIME (Typ.)
- 15ms / 115VAC, 230VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.98/115VAC, PF≧0.95/230VAC, PF≧0.93/277VAC @ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20% (@ load≧50% /115VAC, 230VAC; @ load≧75%/277VAC) (Please refer to “TOTAL HARMONIC DISTORTION (THD)” section)
- EFFICIENCY (Typ.) 230VAC
- 95%
- EFFICIENCY (Typ.) 277VAC
- 95%
- AC CURRENT (Typ.)
- 7A / 115VAC 3.3A / 230VAC 2.9A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 70A(twidth=1000μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 1 unit (circuit breaker of type B) / 2 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- STANDBY POWER CONSUMPTION
- <0.5W at remote off
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 32.5 ~ 36.5V Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
FUNCTION
- REMOTE ON/OFF CONTROL
- Power on : "High" >2 ~ 5V or Open circuit Power off : "Low" <0 ~ 0.5V or Short circuit
- 5V STANDBY
- 5VSB : 5V@0.5A ; tolerance ±5%, ripple : 100mVp-p(max.)
ENVIRONMENT
- WORKING TEMP.
- Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase= +90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 55℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC (Note 10)
- SAFETY STANDARDSNote.7
- UL60950-1, UL8750(type”HL”), CSA C22.2 No. 250.13-12, ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, IP65 or IP67, J61347-1, J61347-2-13, GB/T19510.1,GB/T19510.213, EAC TP TC 004, AS/NZS 60950.1(by CB),KC61347-1, KC61347-2-13(except for AB type) approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSIONNote.7
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3, EAC TP TC 020; GB/T 17743,GB17625.1, KS C 9815, KS C 9547
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020; KS C 9815, KS C 9547
OTHERS
- MTBF
- 913.4K hrs min. Telcordia SR-332 (Bellcore) ; 76.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 280*144*48.5mm (L*W*H)
- PACKING
- 3.9Kg; 4pcs/16.6Kg/0.9CUFT
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The model certified for CCC(GB/T19510.1, GB/T19510.213, GB/T 17743 and GB17625.1) is an optional model . Please contact MEAN WELL for details.
- 8. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 9. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 10. The driver is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 13. For A/AB type need to consider build in using to comply with Type HL application.
Technical drawings
Typical applications
- LED high-bay lighting
- Parking space lighting
- LED fishing lamp
- LED greenhouse lighting
- Type "HL" for use in ClassⅠ, Division 2 hazardous (Classified) location.
Downloads
Certificates6
Catalogues1
FAQ
Can I use the HLG-600H-30B to power 30V LED strip lighting in an outdoor sign cabinet?
Yes. The HLG-600H-30B provides 600W at 30V with up to 20A and carries an IP67 waterproof rating, making it ideal for outdoor sign cabinets where the driver may be exposed to rain or humidity. Its metal housing and -40°C to +90°C case temperature (Tcase) range handle harsh weather conditions.
Is the HLG-600H-30B suitable for dimming large 30V LED installations?
Yes. The B suffix means the driver accepts an external dimming signal (0-10VDC, 10V PWM, or resistance) while providing a full 600W at 30V. This makes it a strong choice for landscape lighting, building facades, or parking lot luminaires where brightness needs to be adjusted remotely or on a schedule.
Can I use the HLG-600H-30B to drive 30V LED flood lights for outdoor sports or area lighting?
Yes. At 600W and 30V, the HLG-600H-30B can power high-wattage 30V LED flood light arrays. Its IP67 rating means it can withstand direct rain and temporary water immersion, so it can be mounted outdoors near the fixtures without a separate weatherproof enclosure.
How many meters of 30V LED strip can the HLG-600H-30B handle?
Divide 600W by your strip's rated power per meter. For a strip consuming 20W/m, you could run up to 30 meters (600W / 20W per meter = 30m). Always verify your strip's rated power per meter and keep the total load at or below 600W for reliable operation.
Can the HLG-600H-30B withstand direct rain and hose-down conditions?
Direct rain, yes. Its IP67 waterproof rating means the enclosure is dust-tight and protected against temporary immersion in water. The datasheet does not rate it for pressurised hose-down cleaning, so avoid direct jets. The case temperature range of -40°C to +90°C adds durability in extreme climates.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.