Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLG-480H-48A is the 48V output model of this series: rated current 10A, rated power 480W, typical efficiency 94.5%.
HLG-480H series is a 480W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-480H operates from 90~305VAC and offers models with different rated voltage ranging between 24V and 54V. Thanks to the high efficiency up to 95.5%, with the fanless design, the entire series is able to operate for -40℃ ~ +90℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications.HLG-480H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
- Constant Voltage + Constant Current mode output
- Metal housing with class I design
- Built-in active PFC function
- IP67 / IP65 design for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off, isolated design) ; smart timer dimming; junction box
- Typical lifettime > 62000 hours
- 7 years warranty (Note.9)
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- CONSTANT CURRENT REGIONNote.4
- 24 ~ 48V
- RATED CURRENT
- 10A
- RATED POWER
- 480W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 40.8 ~ 50.4V
- CURRENT ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 5 ~ 10A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 500ms, 80ms 115VAC/230VAC
- HOLD UP TIME (Typ.)
- 16ms 115VAC/230VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.98/115VAC, PF≧0.97/230VAC, PF≧0.95/277VAC @ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20% (@ load≧40% / 115VAC,230VAC,277VAC) (Please refer to "TOTAL HARMONIC DISTORTION (THD)" section)
- EFFICIENCY (Typ.) 230VAC
- 94.5%
- EFFICIENCY (Typ.) 277VAC
- 95%
- AC CURRENT (Typ.)
- 5A / 115VAC 2.45A / 230VAC 2A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 35A(twidth=1800μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- MAX. NO. of PSUs on 16A CIRCUIT BREAKER
- 2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC
PROTECTION
- OVER CURRENT
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 53 ~ 63V Shut down output voltage, re-power on to recovery
- OVER TEMPERATURE
- Shut down output voltage, re-power on to recovery
ENVIRONMENT
- WORKING TEMP.
- Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase= +90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.02%/℃ (0 ~ 60℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; GB/T19510.1,GB/T19510.213;IP65 or IP67, EAC TP TC 004,AS/NZS IEC 61347.2.13:2013,AS/NZS 61347.1:2016;KC61347-1, KC61347-2-13(except for AB,Dx type), J61347-1(H29), J61347-2-13(H29)(except for Dx type)approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3;GB/T 17743, GB17625.1, EAC TP TC 020;KC KN15,KN61547(except for AB,Dx type),J55015(H29)(for Blank/A-type)
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020 ;KC KN15,KN61547( except for AB,Dx type ),J55015(H29)(for Blank/A-type)
OTHERS
- MTBF
- 1185.9K hrs min. Telcordia SR-332(Bellcore) ; 95.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 262*125*43.8mm (L*W*H)
- PACKING
- 2.8Kg;4pcs/12.2Kg/0.55CUFT
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- 9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 13. For A/AB type need to consider build in using to comply with Type HL application.
Technical drawings
Typical applications
- LED Harboure
- LED greenhouse lighting
- LED statium lighting
- LED mining lighting
- Type "HL" for use in ClassⅠ,Division 2 hazardous(Classified) location
Downloads
Certificates10
Test reports1
Catalogues1
FAQ
Can I use the HLG-480H-48A to fine-tune output for a 48V LED lighting array?
Yes. The A suffix indicates a built-in potentiometer for adjusting output voltage (40.8-50.4V) and current (5-10A). You can trim the 48V output to precisely match your LED array's optimal drive point. This is useful for maximizing efficiency or extending LED lifespan by avoiding over-driving.
Is the HLG-480H-48A suitable for powering 48V LED strips in a long commercial corridor?
Yes. At 480W and 48V, it can handle long LED strip runs common in commercial corridors. The 48V output reduces voltage drop over distance compared to lower-voltage drivers, and the adjustable output lets you compensate for any remaining drop by trimming the voltage slightly upward at the source.
Can the HLG-480H-48A drive 48V LED horticultural lighting in a greenhouse?
Yes. With 480W at 48V and 10A, it has capacity for high-power grow light panels. The adjustable output lets you dial in the exact drive current for different growth stages. However, its IP65 rating protects against water jets and dust but not submersion, so keep it away from direct flooding or standing water in the greenhouse.
How many meters of 48V LED strip can the HLG-480H-48A handle?
Divide 480W by the strip's power rating per meter. A 48V strip consuming 10W/m could run up to 48 meters (480W / 10W per meter = 48m). Always verify your strip's rated power per meter and ensure total load remains at or below 480W.
Is the HLG-480H-48A rated for damp indoor environments like parking garages?
Yes. Its IP65 water-resistant rating protects against dust and low-pressure water jets, which covers the splashing, dripping, and humidity found in parking garages, loading docks, and similar damp indoor spaces. For rain-exposed locations or a risk of temporary immersion, choose the IP67-rated HLG-480H-48 or HLG-480H-48B.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.