Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLG-480H-48 is the 48V output model of this series: rated current 10A, rated power 480W, typical efficiency 94.5%.
HLG-480H series is a 480W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-480H operates from 90~305VAC and offers models with different rated voltage ranging between 24V and 54V. Thanks to the high efficiency up to 95.5%, with the fanless design, the entire series is able to operate for -40℃ ~ +90℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications.HLG-480H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
- Constant Voltage + Constant Current mode output
- Metal housing with class I design
- Built-in active PFC function
- IP67 / IP65 design for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off, isolated design) ; smart timer dimming; junction box
- Typical lifettime > 62000 hours
- 7 years warranty (Note.9)
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- CONSTANT CURRENT REGIONNote.4
- 24 ~ 48V
- RATED CURRENT
- 10A
- RATED POWER
- 480W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 40.8 ~ 50.4V
- CURRENT ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 5 ~ 10A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 500ms, 80ms 115VAC/230VAC
- HOLD UP TIME (Typ.)
- 16ms 115VAC/230VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.98/115VAC, PF≧0.97/230VAC, PF≧0.95/277VAC @ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20% (@ load≧40% / 115VAC,230VAC,277VAC) (Please refer to "TOTAL HARMONIC DISTORTION (THD)" section)
- EFFICIENCY (Typ.) 230VAC
- 94.5%
- EFFICIENCY (Typ.) 277VAC
- 95%
- AC CURRENT (Typ.)
- 5A / 115VAC 2.45A / 230VAC 2A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 35A(twidth=1800μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- MAX. NO. of PSUs on 16A CIRCUIT BREAKER
- 2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC
PROTECTION
- OVER CURRENT
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 53 ~ 63V Shut down output voltage, re-power on to recovery
- OVER TEMPERATURE
- Shut down output voltage, re-power on to recovery
ENVIRONMENT
- WORKING TEMP.
- Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase= +90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.02%/℃ (0 ~ 60℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; GB/T19510.1,GB/T19510.213;IP65 or IP67, EAC TP TC 004,AS/NZS IEC 61347.2.13:2013,AS/NZS 61347.1:2016;KC61347-1, KC61347-2-13(except for AB,Dx type), J61347-1(H29), J61347-2-13(H29)(except for Dx type)approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3;GB/T 17743, GB17625.1, EAC TP TC 020;KC KN15,KN61547(except for AB,Dx type),J55015(H29)(for Blank/A-type)
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020 ;KC KN15,KN61547( except for AB,Dx type ),J55015(H29)(for Blank/A-type)
OTHERS
- MTBF
- 1185.9K hrs min. Telcordia SR-332(Bellcore) ; 95.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 262*125*43.8mm (L*W*H)
- PACKING
- 2.8Kg;4pcs/12.2Kg/0.55CUFT
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- 9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 13. For A/AB type need to consider build in using to comply with Type HL application.
Technical drawings
Typical applications
- LED Harboure
- LED greenhouse lighting
- LED statium lighting
- LED mining lighting
- Type "HL" for use in ClassⅠ,Division 2 hazardous(Classified) location
Downloads
Certificates10
Test reports1
Catalogues1
FAQ
Can I use the HLG-480H-48 to power a large 48V LED strip lighting system?
Yes. The HLG-480H-48 delivers 480W at 48V and up to 10A. 48V LED strips are popular for long runs because they suffer less voltage drop per meter, and 480W gives you substantial capacity. The constant-current mode with a CC range of 24-48V keeps output stable across varying loads.
Is the HLG-480H-48 a good fit for 48V LED high-bay warehouse lighting?
Yes. At 480W and 48V, it can drive high-bay LED fixtures commonly used in warehouses, factories, and distribution centers. Its wide 90-305VAC input handles industrial power supplies, and the IP67-rated metal housing resists dust and moisture found in industrial environments.
Can the HLG-480H-48 power 48V LED modules in outdoor signage?
Yes. With 480W at 48V and IP67 waterproof protection, it can be mounted outdoors to power 48V LED sign modules directly exposed to the elements. Note that this base model has fixed output with no dimming or adjustment, so brightness cannot be changed after installation.
How many meters of 48V LED strip can the HLG-480H-48 power?
That depends on the strip's rated power per meter. The HLG-480H-48 supplies up to 480W at 48V. For example, a strip drawing 14.4W/m would allow about 33 meters (480W / 14.4W per meter = 33.3m). Always check your strip's rated power per meter and keep total load at or below 480W.
Is the HLG-480H-48 suitable for installation in coastal or high-humidity areas?
For high-humidity areas, yes: the IP67-rated metal housing protects against dust and direct water exposure, and working humidity is specified at 20-95% RH non-condensing. The datasheet makes no salt-spray or corrosion claim, so check coastal exposure against the installation guidelines. Its case temperature (Tcase) range is -40°C to +90°C.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.