HLG-240H-48AB is the 48V output model of this series: rated current 5A, rated power 240W, typical efficiency 93%.
HLG-240H series is a 240W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-240H operates from 90~305VAC and offers models with different rated voltage ranging between 12V and 54V. Thanks to the high efficiency up to 93.5%, with the fanless design, the entire series is able to operate for -40℃ ~ +90℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications. HLG-240H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
- Constant Voltage + Constant Current mode output
- Metal housing with class I design
- IP67 / IP65 rating for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming
- Typical lifetime > 62000 hours
- 7 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- CONSTANT CURRENT REGIONNote.4
- 24 ~ 48V
- RATED CURRENT
- 5A
- RATED POWER
- 240W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE ADJ. RANGE
- 44.8 ~ 51.2V
- CURRENT ADJ. RANGE
- 2.5 ~ 5A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 1000ms,80ms/115VAC 500ms,80ms/230VAC
- HOLD UP TIME (Typ.)
- 15ms / 115VAC, 230VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.98/115VAC, PF≧0.95/230VAC @ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20% (@ load≧50% / 115VAC,230VAC; @ load≧75% / 277VAC) (Please refer to " TOTAL HARMONIC DISTORTION (THD) " section)
- EFFICIENCY (Typ.)
- 93%
- AC CURRENT (Typ.)
- 4A / 115VAC 2A / 230VAC 1.2A / 277VAC
- INRUSH CURRENT (Typ.)
- COLD START 75A(twidth=570μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 2 units (circuit breaker of type B) / 4 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENT
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 55 ~ 63V
- OVER TEMPERATURE
- Shut down o/p voltage, recovers automatically after temperature goes down
ENVIRONMENT
- WORKING TEMP.
- Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase= +90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL1012, CAN/CSA-C22.2 No. 107.1-01, UL8750(type”HL”), CSA C22.2 No. 250.0-08; BS EN/EN/AS/NZS 61347-1, BS EN/EN/AS/NZS 61347-2-13 independent (except for HLG-240H C type); IEC/UL/BS EN/EN 62368-1(except for AB,D type), UL8750;GB/T19510.1,GB/T19510. 213(except for C-type); IP65 or IP67;J61347-1,J61347-2-13 (except for C,D-type) , BIS IS15885( for 48V only), EAC TP TC 004,KC61347-1,KC61347-2-13 (except for AB,C,D-type) approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3,GB/T 17743 , GB17625.1,EAC TP TC 020;KC KN15,KN61547(except for AB,C,D-type)
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV) EAC TP TC 020;KC KN15,KN61547(except for AB,C,D-type)
OTHERS
- MTBF
- 2015.1K hrs min. Telcordia SR-332 (Bellcore) ; 176.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 244.2*68*38.8mm (L*W*H)(HLG-240H-Blank/A/B) 251*68*38.8mm (L*W*H)(HLG-240H C-Type)
- PACKING
- 1.3Kg; 12pcs/16.6Kg/0.84CUFT(HLG-240-Blank/A/B) 1.23Kg; 12pcs/15.8Kg/1.16CUFT(HLG-240 C-Type)
Test conditions and notes14
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- 9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com.
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 13. For A/AB type need to consider build in using to comply with Type HL application.
- 14. Products sourced from the Americas regions may only have the UL, CE and UKCA logos. Please contact your MEAN WELL sales for more information.
Technical drawings
Typical applications
- LED street lighting
- LED high-bay lighting
- Parking space lighting
- LED fishing lamp
- LED greenhouse lighting
- Type “HL” for use in ClassⅠ, Division 2 hazardous (Classified) location.
Downloads
FAQ
Can I use the HLG-240H-48AB to power 48V LED strip lighting in a commercial canopy or covered walkway?
Yes. The HLG-240H-48AB provides 240W at 48V and is IP65 water-resistant, which protects against dust and low-pressure water jets. It is well suited for covered outdoor areas such as canopies, walkways, and semi-enclosed signage enclosures where 48V LED strips are used. The built-in dimming input also lets you adjust brightness on-site.
Is the HLG-240H-48AB suitable for dimming 48V LED signage from a building management system?
Yes. The AB suffix indicates both adjustable output and a 1-10V/PWM dimming interface. You can pair with the HLG-240H-48AB to a BMS or lighting controller that outputs a 1-10V or PWM signal to dim the 48V LED signage remotely. The adjustable potentiometer also allows manual fine-tuning of voltage and current.
Can I power 48V LED high-bay fixtures with the HLG-240H-48AB in a warehouse?
Yes. At 240W and 48V with 5A output, the HLG-240H-48AB can drive 48V high-bay LED fixtures up to 240W total. The constant-current mode with a CC range of 24-48V accommodates LED modules with varying forward voltages. The dimming input allows integrating the driver into an occupancy-based lighting control scheme.
How many meters of 48V LED strip can the HLG-240H-48AB support?
That depends on the strip's rated power per meter. The HLG-240H-48AB supplies up to 240W at 48V. For example, if your 48V strip draws 14.4W per meter, you could run up to 240 / 14.4 = 16.6 meters. Always check your strip's rated power per meter and keep total wattage at or below 240W.
Can the HLG-240H-48AB be mounted in a damp location or semi-enclosed outdoor cabinet?
Yes. The IP65 rating protects against dust ingress and low-pressure water jets from any direction, making it suitable for damp locations, ventilated outdoor cabinets, and covered canopy installations. For direct rain exposure or standing water, consider the IP67-rated HLG-240H-48B instead.
What is the difference between the HLG-240H-48, 48A, 48AB, and 48B variants?
All four share 240W / 48V / 5A core specs. The base HLG-240H-48 has fixed output and IP67 waterproof rating. The -48A adds output voltage/current adjustment via potentiometer (IP65). The -48AB adds both adjustment and 1-10V/PWM dimming input (IP65). The -48B provides dimming input only and retains IP67 waterproof rating.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.