Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
EPS-15-36 is the 36V output model of this series: rated current 0.42A, rated power 15.12W, typical efficiency 85%.
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- 1.8"x2.5" compact size
- No load power consumption<0.3W
- Operating altitude up to 3000 meters
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 36V
- RATED CURRENT
- 0.42A
- CURRENT RANGE
- 0 ~ 0.46A
- RATED POWER
- 15.12W
- PEAK LOAD(10sec.)Note.6
- 16.56W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- 32.4 ~ 39.6V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC [DC input operation possible by connecting AC/N(+), AC/L(-)]
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 85%
- AC CURRENT (Typ.)
- 0.4A/115VAC 0.2A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 45A/230VAC
- LEAKAGE CURRENT
- <1mA/240VAC
PROTECTION
- OVER LOAD
- 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 39.7 ~ 46.8V Protection type : Shut down o/p voltage, Clamping by zener diode
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- OPERATING ALTITUDENote.7
- 3000 meters
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, CCC GB4943.1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, GB9254 Class B, GB17625.1
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 6024.7K hrs min. Telcordia SR-332 (Bellcore) ; 849.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 63.5*45.7*24mm (L*W*H)
- PACKING
- 0.057Kg; 120pcs/ 7.84Kg/0.94CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
- 6. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Datasheet1
Certificates9
Test reports1
Catalogues1
FAQ
Can I use the EPS-15-36 for a 36V industrial sensor or transmitter?
Yes, if the device requires a constant 36V supply and draws no more than 0.42A, this model is in range. Its total output is 15.12W, so it is intended for lower-power 36V electronics rather than larger actuators or drives.
Is this a good fit for a small 36V automation module inside a control cabinet?
It can be a fit for compact 36V automation electronics because it provides 36V constant voltage at up to 0.42A. The 63.5 x 45.7 x 24.0 mm size also suits internal cabinet or equipment builds where board space is limited.
Can the EPS-15-36 power a low-current 36V interface board or monitoring device?
Yes, it is suitable for low-current 36V loads up to 0.42A and 15.12W. That makes it more appropriate for interface, sensing, or monitoring electronics than for higher-current 36V equipment.
Would this work for compact embedded equipment that needs 36V DC from AC input?
Yes, the supply accepts 85-264VAC input and converts it to a constant 36V output. It is best used where the embedded or industrial device stays within the 0.42A and 15.12W output rating.
Can the EPS-15-36 be used in cold or hot indoor equipment environments?
The specified operating temperature range is -30C to +70C, with output derating at higher temperatures per the derating curve, which supports a wide range of equipment environments. No IP rating is provided in the listed specs, so exposed outdoor use is not confirmed by the product data shown here.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.