Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
EPP-300-24 is the 24V output model of this series: typical efficiency 92.5%.
Features
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 93%
- Withstand 300VAC surge input for 5 seconds
- Protections: Short circuit / Overload / Over voltage / Over temperature
- Built-in 12V/0.5A auxiliary output
- 5"x3" compact size
- Free air convection for 200W and 300W with 20.5 CFM forced air
- With power good and fail signal output
- Built-in remote sense function
- No load power consumption under 0.5W by PS-ON control
- Standby 5V@1A with fan, @ 0.6A without fan
- Operating altitude up to 5000 meters
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT (20.5CFM)
- 12.5A
- CURRENT RANGE (convection)
- 0 ~ 8.33A
- CURRENT RANGE (20.5CFM)
- 0 ~ 12.5A
- RATED POWER (convection)
- 199.9W
- RATED POWER (20.5CFM)
- 300W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- Main output:22.8 ~ 25.2V
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 2500ms, 30ms/230VAC 3000ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 13ms/230VAC/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.93/230VAC PF>0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 92.5%
- AC CURRENT (Typ.)
- 3.5A/115VAC 1.8A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 40A/115VAC 80A/230VAC
- LEAKAGE CURRENT
- <2mA/240VAC
PROTECTION
- OVERLOAD
- 105 ~ 135% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 26 ~ 30V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- 115℃±5℃ (TSW1) detect on heatsink of power transistor 115±5℃ (12V,15V),100±5℃ (24V,27V,48V) (TSW2) detect on heatsink of output diode Protection type : (TSW1)Shut down o/p voltage, recovers automatically after temperature goes down Protection type : (TSW2)Shut down o/p voltage, re-power on to recover
FUNCTION
- 5V STANDBY
- 5VSB : 5V@0.6A without fan, 1A with fan 20.5CFM ; tolerance ± 2%, ripple : 150mVp-p(max.)
- AUXILIARY POWER (AUX)
- 12V@0.5A for driving a fan ; tolerance -15% ~ +10% at main output 20% rated current (20.5CFM)
- PS-ON INPUT SIGNAL
- Power on: PS-ON = "Hi" or " > 2 ~ 5V" ; Power off: PS-ON = "Low" or " < 0 ~ 0.5V"
- POWER GOOD / POWER FAIL
- 500ms>PG>10ms ; The TTL signal goes high with 10ms to 500ms delay after power set up ; The TTL signal goes low at least 1ms before Vo below 90% of rated value
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃ , 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃ )
- OPERATING ALTITUDENote.7
- 5000 meters
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32),Conduction Class B,Radiation Class B;BS EN/EN61000-3-2,3;EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, BS EN/EN60601-1-2, EAC TP TC 020
OTHERS
- MTBF
- 1490.1K hrs min. Telcordia SR-332 (Bellcore) ; 160.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 127*76.2*35mm (L*W*H)
- PACKING
- 0.37 Kg; 36pcs/14.3Kg/0.96CUFT;
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. Heat Sink HS1,HS2 can not be shorted.
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Datasheet1
Certificates8
Test reports1
Catalogues1
FAQ
Can I use the EPP-300-24 for a 24V PLC, sensor, or industrial I/O system?
Yes, if the system requires a constant 24Vdc source and the total load does not exceed 199.9W or 8.33A with convection cooling, or 300W or 12.5A with 20.5CFM forced airflow. That makes it relevant for many 24V automation loads in the 200-300W class.
Is this a good power supply for 24V embedded computers or industrial communication gear?
It can be, provided the equipment is specified for regulated 24V constant-voltage input and stays within the 8.33A convection-cooled output limit, or 12.5A with 20.5CFM airflow. The unit's 90-264VAC input also supports operation across a broad range of AC mains conditions.
Can the EPP-300-24 power a 24V control cabinet accessory group?
It is suitable for grouped 24Vdc loads when the combined demand remains at or below 199.9W and 8.33A with convection cooling (300W and 12.5A with 20.5CFM airflow). Buyers should confirm the full cabinet load against both current and wattage to avoid oversizing assumptions.
Can this model be used in outdoor or unprotected environments?
Its operating temperature range is listed as -30 degrees C to +70 degrees C, with output derating at higher temperatures per the derating curve. No IP rating is provided in the product data, so the specs do not confirm suitability for direct outdoor exposure, rain, or washdown areas.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.