Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
EPP-150-15 is the 15V output model of this series: typical efficiency 92%.
Features
- 4"x2" Compact size
- Universal AC input / Full range
- Built-in active PFC function
- High efficiency up to 93%
- Protections: Short circuit / Overload / Over voltage/ Over temperature
- 100W free air convection, 150W with 20CFM forced air
- LED indicator for power on
- No load power consumption<0.5W
- Built-in 12V/0.3A auxiliary output
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- RATED CURRENT (convection)
- 6.7A
- RATED CURRENT (20CFM FAN)
- 10A
- CURRENT RANGE (convection)
- 0 ~ 6.7A
- CURRENT RANGE (20CFM FAN)
- 0 ~ 10A
- RATED POWER (convection)
- 100.5W
- RATED POWER (20CFM FAN)
- 150W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 14.7 ~ 15.75V
- VOLTAGE TOLERANCENote.3
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±1.0%
- SETUP, RISE TIME
- 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 16ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.95/230VAC PF>0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 92%
- AC CURRENT (Typ.)
- 1.8A/115VAC 1 A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 70A/230VAC
- LEAKAGE CURRENT
- <2mA/240VAC
PROTECTION
- OVER LOAD
- 105 ~ 145% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 16.83 ~ 19.5V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Protection type : Shut down o/p voltage, re-power on to recover
FUNCTION
- AUXILIARY POWER(AUX)
- 12V@0.3A for driving a fan, tolerance ± 10% at main output 100% load
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 45℃)
- OPERATING ALTITUDENote.5
- 2000 meters
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 6)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC/ 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 2002.2K hrs min. Telcordia SR-332 (Bellcore) ; 207.1K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 101.6*50.8*29mm (L*W*H)
- PACKING
- 0.2Kg; 72pcs/15.4Kg/0.82CUFT
Test conditions and notes6
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 6. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Downloads
Datasheet1
Certificates8
Test reports1
Catalogues1
FAQ
Can I use the EPP-150-15 for 15V industrial instrumentation?
Yes, if the instrument or control electronics require constant 15V DC and the load stays within 6.7A and 100.5W. It is intended for applications that specifically need 15V, not 12V, 24V, 27V, or 48V.
Is this 15V power supply suitable for embedded control or OEM boards?
It can be a fit for embedded systems and OEM assemblies designed around a constant 15V input. The available output is 15V at up to 6.7A, with a 90-264VAC input range.
Can the EPP-150-15 power 15V test fixtures or lab support equipment?
Yes, for equipment that needs a regulated 15V constant-voltage source and remains under 100.5W. The main sizing check is keeping current draw at or below 6.7A.
How do I tell if my 15V device is within this model's capacity?
This power supply is rated for 15V output at 6.7A and 100.5W with convection cooling, or 10A and 150W with a 20CFM fan. If the connected 15V load exceeds the values for your cooling condition, this model is undersized for that application.
Can I use the EPP-150-15 in harsh temperature conditions?
The specified operating range is -30°C to +70°C, with output derating at higher temperatures per the derating curve. The specs do not list an IP rating, so environmental suitability should be treated as indoor and enclosure-protected rather than exposed outdoor use.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.