ENP-360-48 is the 55.2V output model of this series: rated current 6.5A, typical efficiency 94%.

ENP-360 series is a 360W desktop type power supply working perfectly for communication related applications. Observing the standard 7" width size in the land mobile radio field, it provides the most frequently used voltage in the communication field. With the rugged mechanical design along with the high efficiency circuitry, it operates for the ambient temperature range -30℃~+70℃ under free air convection.

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • Energy efficiency Level Ⅵ
  • No load power consumption <0.5W
  • Comply with EISA 2007/DoE, NRCan and EU ErP
  • 125% peak load capability
  • Fanless design, cooling by free air convection
  • Protection: Short circuit / Overload / Over voltage / Over temperature
  • 3 years warranty

Specifications

ENP-360-48Specifications from the official datasheet (2026-03-31 edition)

OUTPUT

DC VOLTAGE
55.2V
RATED CURRENT
6.5A
CURRENT RATED
0 ~ 6.5A
CURRENT PEAKNote.2
8.2A
WATTAGE RATED
359W
WATTAGE PEAKNote.2
453W
RIPPLE & NOISE (max.)Note.3
350mVp-p
VOLTAGE ADJ. RANGE
47.5 ~ 58.8V
VOLTAGE TOLERANCENote.4
±1.0%
LINE REGULATIONNote.5
±0.5%
LOAD REGULATIONNote.6
±0.5%
SETUP, RISE TIMENote.7
1000ms, 100ms at full load
HOLD UP TIME (Typ.)
20ms at full load

INPUT

VOLTAGE RANGENote.8
90 ~ 264VAC 127 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.98/115VAC, PF>0.95/230VAC at full load
EFFICIENCY (Typ.)
94%
AC CURRENT (Typ.)
3.8A/115VAC 1.9A/230VAC
INRUSH CURRENT (Typ.)
COLD START 60A at 230VAC
LEAKAGE CURRENT
<3.5mA / 240VAC
NO LOAD POWER CONSUMPTION
<0.5W

PROTECTION

SHORT CIRCUIT
Protection type : Constant current limiting, recovers automatically after fault condition is removed
OVERLOAD
Normally works within 110 ~ 125% rated output power for more than 3 seconds and switches to constant current limiting, with auto-recovery after the peak load condition is removed Constant current limiting, if >125% rated power, with auto-recovery after the overload condition is removed
OVER VOLTAGE
62.1 ~ 72.9V Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down O/P voltage, recovers automatically after temperature goes down

ENVIRONMENT

WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.05%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
IEC62368-1, UL62368-1, EAC TP TC 004, J62368-1(2020)(Only for 12V,24V) approved; Meet BS EN/ EN62368-1
WITHSTAND VOLTAGE
I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55032 (CISPR32) / FCC PART15 (CISPR22)Class B
RadiatedBS EN/EN55032 (CISPR32) / FCC PART15 (CISPR22)Class B
Harmonic CurrentBS EN/EN61000-3-2
Voltage FlickerBS EN/EN61000-3-3
EMC IMMUNITYNote 9

BS EN/EN55024; J55032(H29) (Only for 12V,24V)

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 2, 4KV contact
RadiatedBS EN/EN61000-4-3Level 2, 3V/m
EFT / BurstBS EN/EN61000-4-4Level 2, 1KV
SurgeBS EN/EN61000-4-5Level 2, 1KV/Line-Line,Level 3, 2KV/Line-Earth
ConductedBS EN/EN61000-4-6Level 2, 3Vrms
Magnetic FieldBS EN/EN61000-4-8Level 1, 1A/m
Voltage Dips and InterruptionsBS EN/EN61000-4-11>95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods

OTHERS

MTBF
1199.8K hrs min. Telcordia SR-332 (Bellcore) ; 147.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
192*178*45.5mm (L*W*H)
PACKING
1.5Kg; 10pcs/16Kg /1.38CUFT
Test conditions and notes10
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Peak current or peak power up to 3 seconds is provided.
  3. 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  4. 4. Tolerance : includes set up tolerance, line regulation and load regulation.
  5. 5. Line regulation is measured from low line to high line at rated load.
  6. 6. Load regulation is measured from 0% to 100% rated load.
  7. 7. Length of set up time is measured at cold first start. Turning ON/OFF the power supply very quickly may lead to increase of the set up time.
  8. 8. Derating may be needed under low input voltages. Please check the derating curve for more details.
  9. 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  10. 10. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

ENP-360-48 Block Diagram
Block Diagram
ENP-360-48 Mechanical Specification
Mechanical Specification

Typical applications

  • Land mobile radio system
  • Surveillance system
  • TV antenna facility

Downloads

FAQ

What are the key output specifications of the Mean Well ENP-360-48?

The ENP-360-48 is a 360W-class desktop power supply (359W rated) with an output of 55.2V DC at 6.5A. It is designed for applications that require this specific voltage and current combination. It can also deliver a peak of 453W (8.2A) for up to 3 seconds for short-duration demand.

Can the ENP-360-48 be used with international AC power sources?

Yes. This model supports a universal AC input range of 90 to 264VAC, as well as 127 to 370VDC input. That makes it suitable for use in regions with different mains voltage standards.

What protection features are included in this power supply?

This model includes protection for short circuit, overload, over-voltage, and over-temperature conditions. Its overload behavior is specified to operate within 110% to 125% of rated output power for more than 3 seconds before switching to constant current limiting. It then auto-recovers after the peak load condition is removed.

What efficiency and energy compliance standards does the ENP-360-48 meet?

The ENP-360-48 is a Level VI desktop power supply with a typical efficiency of 94%. It also has no-load power consumption below 0.5W. These features make it a stronger fit for energy-conscious commercial applications.

What kinds of applications is the ENP-360-48 typically suited for?

This model is generally suited for equipment that needs a regulated 55.2V DC output at up to 6.5A in a desktop form factor. Buyers often consider it where high efficiency and power factor correction (PF>0.95 at full load) are important. The exact application should match the equipment's required voltage and current specifications.

What are the physical size and weight of the ENP-360-48?

The unit measures 192 x 178 x 45.5 mm and has a listed weight of 1.5 kg. Those details can help when comparing enclosure space and portability.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8655342993728, "variants" :[{ "context":"default", "variant_id": 46624483868992, "sku":"ENP-360-48", "inventory_qty" : 0, "customer" :true, "custom_html" :"\u003cdiv class=\"price\"\u003e\n \u003cdiv class=\"price__default\"\u003e\n \u003cstrong class=\"price__current\"\u003e$113.29\u003c\/strong\u003e\n \u003cs class=\"price__was\"\u003e\u003c\/s\u003e\n \u003c\/div\u003e\n\n \u003cdiv class=\"unit-price relative\" hidden\u003e\u003cspan class=\"visually-hidden\"\u003eUnit price\u003c\/span\u003e\u003cspan class=\"unit-price__price\"\u003e\u003c\/span\u003e\u003cspan class=\"unit-price__separator\"\u003e \/ \u003c\/span\u003e\u003cspan class=\"unit-price__unit\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv class=\"price__no-variant\" hidden\u003e\n \u003cstrong class=\"price__current\"\u003eUnavailable\u003c\/strong\u003e\n \u003c\/div\u003e\n\n \u003c\/div\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well ENP-360-48 Desktop Type Chargers 360W 55.2V 6.5A - Level VI Power Supply
Mean Well

Mean Well ENP-360-48 Desktop Type Chargers 360W 55.2V 6.5A - Level VI Power Supply

$113.29 USD

ENP-360-48 is the 55.2V output model of this series: rated current 6.5A, typical efficiency 94%.

ENP-360 series is a 360W desktop type power supply working perfectly for communication related applications. Observing the standard 7" width size in the land mobile radio field, it provides the most frequently used voltage in the communication field. With the rugged mechanical design along with the high efficiency circuitry, it operates for the ambient temperature range -30℃~+70℃ under free air convection.

Features

  • Universal AC input / Full range
  • Built-in active PFC function
  • Energy efficiency Level Ⅵ
  • No load power consumption <0.5W
  • Comply with EISA 2007/DoE, NRCan and EU ErP
  • 125% peak load capability
  • Fanless design, cooling by free air convection
  • Protection: Short circuit / Overload / Over voltage / Over temperature
  • 3 years warranty

Typical applications

  • Land mobile radio system
  • Surveillance system
  • TV antenna facility