Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well DDR-120B-48 DC-DC Converter - 120W - 16.8~33.6V in 48V out 2.5A

$76.53 USD
Shipping calculated at checkout.
Model

|

Your order will be processed within 24 hours

Overview

DDR-120B-48 is the 48V output model of this series: rated current 2.5A, rated power 120W, typical efficiency 91%.

DDR-120 series is a 120W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra slim width (32mm), 2:1 wide input voltage, fanless design, -40~+70℃ wide operating temperature, 4KVdc I/O isolation, 150% peak load, adjustable output voltage and full protective functions. This series of models has various input options: 9~18V / 16.8~33.6V / 33.6~67.2V / 67.2~154V and various output options: 12V / 24V / 48V and can be used for industrial & railway control, security control, communication system and other fields. Suitable applications include DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.

Features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Width only 32mm
  • 2:1 wide input range
  • -40~+70℃ wide working temperature
  • 150% peak load capability
  • DC output adjustable
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity / Input under voltage protection
  • 4KVdc I/O isolation(Reinforced isolation)
  • Conformal coating
  • 3 years warranty

Specifications

DDR-120B-48Specifications from the official datasheet (2026-09-10 edition)

OUTPUT

DC VOLTAGE
48V
RATED CURRENT
2.5A
CURRENT RANGE
0 ~ 2.5A
RATED POWER
120W
PEAK CURRENT
3.75A
PEAK POWERNote.5
180W (3sec.)
RIPPLE & NOISE (max.)Note.2
50mVp-p
VOLTAGE ADJ. RANGE
48 ~ 56V
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±1.0%
SETUP, RISE TIME
500ms, 60ms @24Vdc
HOLD UP TIME (Typ.)
Please refer to page 7 Hold up Time( Load de-rating curve )

INPUT

VOLTAGE RANGENote.4
16.8 ~ 33.6Vdc
EFFICIENCY (Typ.)
91%
DC CURRENT (Typ.)
5.6A @24Vdc
INRUSH CURRENT (Typ.)
5A @ 24Vdc
INTERRUPTION OF VOLTAGE SUPPLY
EN50155:2021-comply with S1 level

PROTECTION

OVERLOAD
Normally works within 150% rated output power for more than 3 seconds and then constant current protection 105~135% rated output power with auto-recovery
OVER VOLTAGE
57.6 ~ 67.2V Protection type : Shut down o/p voltage, re-power on to recover
REVERSE POLARITY
By internal MOSFET, no damage, recovers automatically after fault condition removed
UNDER VOLTAGE LOCKOUT
24Vin (B - type) :Power ON≥16.8V , OFF≤16.5V

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
5 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 5 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 55℃)
VIBRATION
Component:10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes; Mounting: Compliance to IEC61373
OPERATING ALTITUDE
5000 meters

SAFETY & EMC

SAFETY STANDARDS
IEC 62368-1, UL 62368-1, EAC TP TC 004, AS/NZS 62368.1 approved; Design refer to UL508
WITHSTAND VOLTAGE
I/P-O/P:4KVdc I/P-FG:2.5KVdc O/P-FG:2.5KVdc
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:>100M Ohms / 500Vdc / 25℃/ 70% RH
EMC EMISSIONNote 6
ParameterStandardTest Level
ConductedBS EN/EN55032Class B
RadiatedBS EN/EN55032Class B
Voltage FlickerBS EN/EN61000-3-3
EMC IMMUNITYNote 6

BS EN/EN55035 , BS EN/EN61000-6-2(BS EN/EN50082-2)

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 3, 6KV contact; criteria A
RadiatedBS EN/EN61000-4-3Level 3, 10V/m; criteria A
EFT / BurstBS EN/EN61000-4-4Level 3, 2KV; criteria A
SurgeBS EN/EN61000-4-5Level 3, 1KV/Line-Line ;Level 3, 2KV/Line-Line-FG ;criteria A
ConductedBS EN/EN61000-4-6Level 3, 10V; criteria A
Magnetic FieldBS EN/EN61000-4-8Level 4, 30A/m; criteria A
RAILWAY STANDARD
Compliance to BS EN/EN45545-2 for fire protection ; Meet BS EN/EN50155 / IEC60571 including IEC61373 for shock & vibration, BS EN/EN50121-3-2 for EMC (except for 9~18Vin)

OTHERS

MTBF
1769.5K hrs min. Telcordia SR-332 (Bellcore) ; 214.5K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
32*125.2*102mm (W*H*D)
PACKING
510g; 28pcs/15.3Kg/1.23CUFT
Test conditions and notes7
  1. 1. All parameters NOT specially mentioned are measured at normal input (A:12Vdc , B:24Vdc) , rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Derating may be needed under low input voltage. Please check the derating curve for more details.
  5. 5. 3 seconds max., please refer to peak loading curves.
  6. 6. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
  7. 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).

Technical drawings

DDR-120B-48 Block Diagram
Block Diagram
DDR-120B-48 Derating Curve
Derating Curve
DDR-120B-48 Input Under-Voltage Protection
Input Under-Voltage Protection
DDR-120B-48 Inrush Current
Inrush Current
DDR-120B-48 Hold-up Time
Hold-up Time
DDR-120B-48 Efficiency vs Load & Vin Curve
Efficiency vs Load & Vin Curve
DDR-120B-48 D D R - 1 2 0 series
D D R - 1 2 0 series
DDR-120B-48 Mechanical Specification
Mechanical Specification

Typical applications

  • Bus,tram,metro or railway system
  • Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical
  • Wireless network
  • Telecom or datacom system

Downloads

FAQ

Can I use the DDR-120B-48 to power 48V networking equipment from a 24V DC bus?

Yes. The DDR-120B-48 steps up a 16.8–33.6V DC input to 48V at up to 2.5A (120W). This suits PoE switches, network routers, and telecom equipment that require a 48V supply, commonly deployed in industrial Ethernet or building automation networks fed by 24V DC infrastructure.

Is this converter suitable for powering 48V DC loads in a railway signaling cabinet?

The DDR-120B-48 operates from -40°C to +70°C (with derating per the derating curve), features 4KVdc isolation, and meets EN 50155 / IEC 60571, EN 50121-3-2 for EMC and EN 45545-2 for fire protection, making it robust for railway environments with wide temperature swings and electrical noise. Its 120W output at 48V can supply signaling relays, communication modules, or monitoring systems from a 24V trackside DC bus.

Can I use the DDR-120B-48 to create a 48V bus for PoE-powered IP cameras from a 24V solar system?

Yes. With a 16.8–33.6V input range, the DDR-120B-48 accepts voltage from a 24V solar battery bank and converts it to 48V at 2.5A. This is enough to power a small PoE switch serving several IP cameras in a remote surveillance application.

Can the DDR-120B-48 operate without ventilation in a dust-prone industrial environment?

The datasheet does not specify a forced-airflow requirement or an ingress rating for the unit. It can be mounted in a sealed enclosure as long as internal temperatures remain within the -40°C to +70°C operating range, with derating per the derating curve. For dusty environments, a sealed NEMA 12 or IP54 cabinet is recommended.

Is the DDR-120B-48 appropriate for charging 48V lithium battery packs?

The DDR-120B-48 is a DC-DC converter with a regulated 48V output (adjustable 48–56V). It is not specified as a battery charger, and the datasheet lists no CC/CV charge profiles or battery management features; its constant-current overload mode is a protection function, not charge control. For lithium battery charging, a dedicated charger with proper charge algorithms is required.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8658888622400, "variants" :[{ "context":"default", "variant_id": 46633107980608, "sku":"DDR-120B-48", "inventory_qty" : 103, "customer" : true, "custom_html" :"\u003cdiv class=\"price\"\u003e\n \u003cdiv class=\"price__default\"\u003e\n \u003cstrong class=\"price__current\"\u003e$76.53\u003c\/strong\u003e\n \u003cs class=\"price__was\"\u003e\u003c\/s\u003e\n \u003c\/div\u003e\n\n \u003cdiv class=\"unit-price relative\" hidden\u003e\u003cspan class=\"visually-hidden\"\u003eUnit price\u003c\/span\u003e\u003cspan class=\"unit-price__price\"\u003e\u003c\/span\u003e\u003cspan class=\"unit-price__separator\"\u003e \/ \u003c\/span\u003e\u003cspan class=\"unit-price__unit\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv class=\"price__no-variant\" hidden\u003e\n \u003cstrong class=\"price__current\"\u003eUnavailable\u003c\/strong\u003e\n \u003c\/div\u003e\n\n \u003c\/div\u003e\n", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well DDR-120B-48 DC-DC Converter - 120W - 16.8~33.6V in 48V out 2.5A
Mean Well

Mean Well DDR-120B-48 DC-DC Converter - 120W - 16.8~33.6V in 48V out 2.5A

$76.53 USD

DDR-120B-48 is the 48V output model of this series: rated current 2.5A, rated power 120W, typical efficiency 91%.

DDR-120 series is a 120W DIN Rail type DC-DC converter with main features including DIN rail-type easy installation, ultra slim width (32mm), 2:1 wide input voltage, fanless design, -40~+70℃ wide operating temperature, 4KVdc I/O isolation, 150% peak load, adjustable output voltage and full protective functions. This series of models has various input options: 9~18V / 16.8~33.6V / 33.6~67.2V / 67.2~154V and various output options: 12V / 24V / 48V and can be used for industrial & railway control, security control, communication system and other fields. Suitable applications include DC buck/boost regulator, increasing system insulation level and voltage drop compensation along cable...etc.

Features

  • Compliance to BS EN/EN50155 and BS EN/EN45545-2 railway standard
  • Width only 32mm
  • 2:1 wide input range
  • -40~+70℃ wide working temperature
  • 150% peak load capability
  • DC output adjustable
  • Cooling by free air convection
  • Can be installed on DIN rail TS-35/7.5 or 15
  • Protections: Short circuit / Overload / Over voltage / Input reverse polarity / Input under voltage protection
  • 4KVdc I/O isolation(Reinforced isolation)
  • Conformal coating
  • 3 years warranty

Typical applications

  • Bus,tram,metro or railway system
  • Industrial control system
  • Semiconductor fabrication equipment
  • Factory automation
  • Electro-mechanical
  • Wireless network
  • Telecom or datacom system

Model

  • 12V out 120W
  • 12V out 400W
  • 24V out 120W
  • 24V out 240W
  • 24V out 480W
  • 48V out 120W
  • 48V out 240W
  • 48V out.480W
View product