Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
IRM-90-48ST is the 48V output model of this series: typical efficiency 93%. Type ST: Screw terminal style.
IRM-90 is a 90W miniature (87*52*29.5mm) AC-DC PCB-mount module type power supply, ready to be soldered onto the PCB boards of various kinds of electronic instruments or industrial automation equipments. This product allows the universal input voltage range of 80~305Vac. The 94V-0 flame retardant plastic case and potted with silicone enhance the heat dissipation and meet the anti-vibration demand up to 2~5G anti-vibration by model; moreover, it provides the fundamental resistance to dust and moisture. With the high efficiency up to 93% and the extremely low no-load power consumption below 0.3W, IRM-90 series fulfills the worldwide regulation for the low power consumption requirement for electronics. The entire series is a Class Ⅱ design (no FG pin), incorporating the built-in EMI filtering components, enabling the compliance with BS EN/EN55032 Class B; the super EMC features keep the end electronic units from from electromagnetic interference. In addition to the PCB mounting style model, IRM-90 series also offers the screw terminal style model (ST).
Features
- 3.43"x2.05" compact size
- PCB, chassis or screw terminal mounting version
- Universal input 80~305Vac
- No load power consumption<0.3W
- EMI BS EN/EN55032 ClassB without additional components
- Wide operating temp. rage -40~+85℃
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Isolation Class Ⅱ
- Over voltage category Ⅲ
- Operating altitude up to 4000 meters (Note.7)
- 100W peak(10 sec.)
- 3 years warranty
Model encoding
| Type | Function |
|---|---|
| Blank | PCB mounting style |
| ST (this model) | Screw terminal style |
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- CURRENT Peak(10 sec.)
- 2.07A
- CURRENT Convection
- 1.88A
- RATED POWER Peak(10 sec.)Note.2
- 99.2W
- RATED POWER Convection
- 90.2W
- RIPPLE & NOISE (max.)Note.3
- 240mVp-p
- VOLTAGE TOLERANCENote.4
- ±2.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 30ms/230Vac 1000ms, 30ms/115Vac at full load
- HOLD UP TIME (Typ.)
- 30ms/230Vac 10ms/115Vac at full load
INPUT
- VOLTAGE RANGENote.5
- 80 ~ 305Vac 113 ~ 431Vdc
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 93%
- AC CURRENT (Typ.)
- 1.9A/115Vac 1.1A/230Vac
- INRUSH CURRENT (Typ.)
- COLD START 30A/115Vac 65A/230Vac
- LEAKAGE CURRENT (max.)Note.6
- < 0.25mA/240Vac
PROTECTION
- OVERLOAD
- 115% ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 50.4 ~ 64.8V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP.
- -40 ~ +85℃
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- SOLDERING TEMPERATURE
- Wave soldering: 265℃,5s (max.); Manual soldering: 390℃,3s (max.)
- VIBRATION
- Blank:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
- OPERATING ALTITUDENote.7
- Ⅲ; EN62368-1;altitude up to 2000 meters
SAFETY & EMC
- SAFETY STANDARDS
- IEC62368-1, IEC60335-1, Dekra BS EN/EN60335-1,BS EN/EN62368-1,UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:4KVac
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500Vdc / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 (CISPR32),BS EN/EN55014-1 Class B Radiated BS EN/EN55032 (CISPR32),BS EN/EN55014-1 Class B Harmonic Current BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN55035, BS EN/EN61000-6-2,BS EN/EN55014-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact, criteria A RF field susceptibility BS EN/EN61000-4-3 Level 3, criteria A EFT bursts BS EN/EN61000-4-4 Level 3, criteria A Surge susceptibility BS EN/EN61000-4-5 Level 4,2KV/L-N, criteria A Conducted susceptibility BS EN/EN61000-4-6 Level 3, criteria A Magnetic field immunity BS EN/EN61000-4-8 Level 4, criteria A Voltage dip, interruption BS EN/EN61000-4-11 >95% dip 0. 5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 5088.4K hrs min. Telcordia SR-332 (Bellcore) ; 609.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- PCB mounting style : 87*52*29.5mm (L*W*H) Screw terminal style : 109*52*33.5mm (L*W*H)
- PACKING
- PCB mounting style : 0.197Kg;60pcs/11.8Kg/0.94CUFT Screw terminal style :0.219Kg;50pcs/12Kg/0.56CUFT
Test conditions and notes8
- 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
- 2. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 4. Tolerance : includes set up tolerance, line regulation and load regulation.
- 5. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 6. Leakage current was measured from primary input to DC output.
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 8. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Typical applications
- Industrial electrical equipment
- Mechanical equipment
- Factory automation equipment
- Handheld electronic device
Downloads
Datasheet1
Certificates9
Test reports1
Catalogues1
FAQ
Can I use the IRM-90-48ST for a 48V industrial control cabinet or panel supply?
Yes, it is a constant-voltage 48V power supply rated for up to 1.88A and 90.2W, which fits many industrial control and panel-level 48V loads. The screw terminal style makes it a practical choice where a compact encapsulated supply is needed in control equipment powered from 80-305VAC.
Is the IRM-90-48ST a good fit for 48V building automation or machine-control subsystems?
It can be used for 48V automation and machine-control subsystems when the connected load requires constant 48V DC and stays within 1.88A. The wide 80-305VAC input range also makes it usable across installations with different AC input conditions.
Can this model power a 48V communications, alarm, or supervisory device inside equipment?
Yes, it can support 48V communications, alarm, or supervisory devices in enclosed equipment as long as total demand does not exceed 90.2W. This model is best matched to applications that need a fixed 48V output rather than an adjustable or constant-current source.
Would the IRM-90-48ST work for a serviceable OEM product that uses 48V DC internally?
It is suitable for OEM products that need internal 48V DC power up to 1.88A and benefit from an encapsulated construction. Compared with the PCB mounting version, this ST version uses a screw terminal style and has a larger 109.0 × 52.0 × 33.5 mm footprint at 0.219 kg.
What is the difference between the IRM-90-48ST and IRM-90-48?
Both models have the same electrical rating: 90.2W, 48V, 1.88A, constant-voltage operation, 80-305VAC input, and -40°C to +85°C operating temperature (with derating per the derating curve). The difference is the mechanical format: IRM-90-48 is PCB mounting style at 87.0 × 52.0 × 29.5 mm and 0.197 kg, while IRM-90-48ST is screw terminal style at 109.0 × 52.0 × 33.5 mm and 0.219 kg.
Can the IRM-90-48ST be used in outdoor or temperature-variable locations?
Its rated operating range is -40°C to +85°C, with output derating at higher temperatures per the derating curve, so the temperature specification covers both cold and hot equipment environments. No IP rating is provided in the listed specs, so it should be used in protected indoor housings or sheltered enclosures instead of exposed outdoor conditions.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other IRM-90 Models
7 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well IRM-90-48 Switching Power Supply 99.2W 48V 2.07A - Encapsulated | 90.2W | 48V | 1.88A | View |
| Mean Well IRM-90-24ST Switching Power Supply 99W 24V 4.13A - Encapsulated | 90W | 24V | 3.75A | View |
| Mean Well IRM-90-24 Switching Power Supply 99W 24V 4.13A - Encapsulated | 90W | 24V | 3.75A | View |
| Mean Well IRM-90-15ST Switching Power Supply 93.5W 15V 6.23A - Encapsulated | 85.05W | 15V | 5.67A | View |
| Mean Well IRM-90-15 Switching Power Supply 93.5W 15V 6.23A - Encapsulated | 85.05W | 15V | 5.67A | View |
| Mean Well IRM-90-12ST Switching Power Supply 88.4W 12V 7.37A - Encapsulated | 80.4W | 12V | 6.7A | View |
| Mean Well IRM-90-12 Switching Power Supply 88.4W 12V 7.37A - Encapsulated | 80.4W | 12V | 6.7A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.