Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SKA40A-12 is the 12V output model of this series: rated power 40W, typical efficiency 90%.
Features
- 2:1 wide input range
- High efficiency up to 92%
- 1500VDC I/O isolation
- Built-in EMI filter
- Built-in remote ON / OFF control
- Built-in remote sense
- Trimming output ±10%
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Six-sided shield metal case
- 100% burn-in test
- Low cost / High reliability
- Output 3.3V/9V available
- Approvals: FCC / EAC / CE / UKCA
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- CURRENT RANGE
- 0.3 ~ 3.33A
- RATED POWER
- 40W
- RIPPLE & NOISE (max.)Note.2
- 80mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- ±0.5%
- VOLTAGE ACCURACY
- ±2.0%
- SWITCHING FREQUENCY
- 200KHz min.
- EXTERNAL CAPACITANCE LOAD (max.)
- 1000uF
- EXTERNAL TRIM Adj. RANGE(Typ.)
- ±10%
INPUT
- VOLTAGE RANGE
- 9 ~ 18VDC
- EFFICIENCY (Typ.)
- 90%
- DC CURRENT Full load
- 3850mA
- DC CURRENT No load
- 150mA
- FILTER
- Pi network
- REMOTE CONTROL
- Power ON : R.C ~ -Vin > 2.5V ~ 75VDC or open circuit ; Power OFF : R.C ~ -Vin < 0.5VDC or short
- PROTECTION
- Fuse recommended
PROTECTION (Note. 5)
- OVER CURRENT
- 110% ~ 180% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- All output equipped with short circuit Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 5Vo : 7V ~ 8.95V ; 12Vo : 15V ~ 19.2V ; 15Vo : 18V ~ 23.3V Protection type : Clamp by TVS diode
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +80℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -55 ~ +105℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- EAC TP TC 020/2011 (EAC TP TC 004 for 48Vin type only) approved
- WITHSTAND VOLTAGE
- I/P-O/P:1.5KVDC
- ISOLATION RESISTANCE
- I/P-O/P: 100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 Class A, FCC part 15 Class A, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8, light industry level, criteria A, EAC TP TC 020
OTHERS
- DIMENSION
- 50.8*50.8*11.0 mm or 2"*2"*0.43" inch (L*W*H)
- PACKING
- 50g ; 5pcs/per tube, 200pcs/40 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input, rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1uf & 47uf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 10% to 100% rated load.
- 5.Please prevent the converter from operating in overload or short circuit condition for more than 30 seconds.
Technical drawings
Downloads
FAQ
Can I use the SKA40A-12 for 12V industrial sensors, relays, or control modules in a 9-18VDC system?
This unit delivers constant-voltage 12V output at up to 3.33A with 40W capacity. It is a match for 12V industrial or automation loads that stay within those output limits and use a 9-18VDC input source.
Is the SKA40A-12 suitable for powering 12V embedded or communications equipment?
The listed output is a regulated 12V rail with up to 3.33A available. That fits embedded or communications hardware that requires 12V and remains within the 40W maximum output.
Can the SKA40A-12 be used in mobile or battery-adjacent control equipment with a 9-18VDC input range?
Its published input range is 9-18VDC, and it converts that to a constant 12V output. For control equipment operating in that source window, the main sizing limits are 40W total power and 3.33A output current.
Does this converter fit compact automation assemblies that need moderate 12V power?
The housing measures 50.8 × 50.8 × 11.0 mm and weighs 50g. Those dimensions can help when integrating a 12V, 40W converter into smaller embedded or industrial assemblies.
Is the SKA40A-12 intended for indoor or outdoor use?
The specified operating temperature range is -40°C to +80°C, which covers demanding temperature conditions. No IP rating is provided in the specs, so exposed outdoor suitability is not confirmed from the published data.
How does the SKA40A-12 compare with the other SKA40A output options?
The SKA40A-12 is the 12V version in the series, rated at 40W and 3.33A. The SKA40A-05 is 35W with 5V at 7A, while the SKA40A-15 is 40W with 15V at 2.67A.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.