Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
SCWN06W8-12 is the 12V output model of this series: rated power 6W, typical efficiency 85%.
SCWN06W8 and DCWN06W8 series are 6W isolated and regulated module type DC-DC converter with DIP24 package. It features international standard pins, a high efficiency up to 86%, wide working temperature range -40~+95℃, 3KVdc I/P-O/P isolation voltage, Compliance to BS EN/EN55032 radiated Class B without additional components, continuous-mode short circuit protection, 8:1(9~75V) ultra-wide input range, and various output voltage, 3.3V/5V/12V/15V for single output and ±5V/±12V/±15V for dual outputs, which are suitable for all kinds of systems, such as industrial control, telecommunication field, distributed power architecture, and so on.
Features
- DIP24 package with industry standard pinout
- 8:1(9~75Vdc) ultra-wide input range
- Operating temperature range -40 ~ +95℃
- No minimum load required
- Comply to BS EN/EN55032 radiated Class B without additional components
- High efficiency up to 86%
- Protections: Short circuit (Continuous) / Overload / Over voltage / UVLO
- Remote ON/OFF control (Optional)
- 3KVdc I/O isolation
- 3 years warranty
Specifications
MODEL SELECTION TABLE
- INPUT VOLTAGE (RANGE)
- Nominal 12V, 24V,36V,48V,72V (9 ~ 75V)
- INPUT CURRENT NO LOAD
- 5mA
- INPUT CURRENT FULL LOAD
- 147mA
- OUTPUT VOLTAGE
- 12V
- OUTPUT CURRENT
- 500mA
- EFFICIENCY (TYP.)
- 85%
- CAPACITOR LOAD (MAX.)* For each output
- 1000μF
INPUT
- VOLTAGE RANGE
- 9~75Vdc
- SURGE VOLTAGE (100ms max.)
- 100Vdc
- FILTER
- Pi type
- PROTECTION (Typ.)
- 2A Fast-Acting Type
OUTPUT
- VOLTAGE ACCURACY
- ±2% for 3.3Vo, ±1.5% for others
- RATED POWER
- 6W
- RIPPLE & NOISENote.2
- 100mVp-p
- LINE REGULATIONNote.3
- ±0.5%
- LOAD REGULATIONNote.4
- Single output models:±0.5% ; Dual output models:±1.0%
- CROSS DEGUIATION
- ±5% @ 25%~100% Load only for dual output
- SWITCHING FREQUENCY (Typ.)
- 300KHz
PROTECTION
- SHORT CIRCUIT
- Protection type : Continuous, automatic recovery
- OVERLOAD
- 110 ~ 230% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- Protection type : Clamp by zener diode
- UNDER VOLTAGE LOCKOUT (Typ.) Start-up voltage
- 8.8Vdc
- UNDER VOLTAGE LOCKOUT (Typ.) Shutdown voltage
- 8Vdc
ENVIRONMENT
- COOLING
- Free-air convection
- WORKING TEMP.
- -40 ~ +95℃ (Refer to "Derating Curve")
- CASE TEMPERATURE
- +115℃ max.
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +100℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.05% / ℃ max. (0 ~ 85℃)
- SOLDERING TEMPERATURE
- 1.5mm from case of 1 ~ 3sec./260℃ max.
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note.5)
- SAFETY STANDARDS
- EAC TP TC 020/2011 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVdc
- ISOLATION RESISTANCE
- I/P-O/P:1000M Ohms / 500Vdc / 25℃/ 70% RH
- ISOLATION CAPACITANCE (Typ.)
- 1000pF
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A without additional components Class B with additional components Radiated BS EN/EN55032 Class B without additional components - EMC IMMUNITY
-
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 2, ±8KV air, ±4KV contact Radiated Susceptibility BS EN/EN61000-4-3 Level 2, 3V/m EFT/Bursts BS EN/EN61000-4-4 Level 2, 0.5KV Surge BS EN/EN61000-4-5 Level 2, 1KV Line-Line Conducted BS EN/EN61000-4-6 Level 2, 3V(e.m.f.)
OTHERS
- MTBF (Typ.)
- 2500Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- 31.8*20.3*10.2mm (1.25*0.8*0.4 inch)
- CASE MATERIAL
- Non-Conductive black plastic (UL 94V-0 rated)
- PACKING
- 12.5g ; 10pcs/per tube, 600pcs/60 tube/per carton
Test conditions and notes5
- 1.All parameters are specified at normal input (48Vdc), rated load, 25℃ 70% RH ambient.
- 2.Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μf & 47μf capacitor.
- 3.Line regulation is measured from low line to high line at rated load.
- 4.Load regulation is measured from 0% to 100% rated load.
- 5.The final equipment must be re-confirm that it still meet EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.”(as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Telecom/datacom system
- Wireless network
- Industrial control facility
- Instrument
- Analyzer
- Detector
- Data switch
Downloads
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.




