Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
DDRH-30-48ST is the 48V output model of this series: rated power 30W, typical efficiency 91%.
DDRH-30 series is a 150 ~ 1500Vdc high reliable ultra-high input DC-DC converter which can supply stable working voltage for the load. Main features are as following: compact size, -40~+80℃ wide range operating temperature, 4KVac high isolation voltage, operation at 5000m altitude, low ripple & noise, complete protections and so on. Futhermore, this series also has DIN Rail type, it is suitable to be mounted on TS-35/7.5 or TS-35/15 rails. DDRH-30 is designed to meet UL1741and IEC62109-1 standard. It is suitable for industrial automation, surveillance, telecommunication and can be widely deployed in the applications of new energy generation such as solar power, and windmill power generation, for instances, photovoltaic power systems, high voltage inverting , DC bus centralized application , ESS, charging pile, railway and so forth.
Features
- 150~1500Vdc 10:1 ultra-wide input range
- 4KVac I/O high isolation(Reinforced isolation)
- Protections: Short circuit / Overload / Over voltage / DC input under voltage / DC input reverse Polarity
- Fanless design, fully encapsulated, cooling by free air convection
- Can be installed on DIN rail TS-35/7.5 or 15 (DR-Type)
- -40~+80℃ ultra-wide operating temperature (>+50℃ derating)
- Operating altitude up to 5000 meters
- 3 years warranty
Specifications
INPUT
- INPUT VOLTAGE (RANGE)
- Nominal 800Vdc (150~1500Vdc)
- INPUT CURRENT NO LOAD
- 0.2mA
- INPUT CURRENT FULL LOAD
- 50mA
- VOLTAGE RANGE
- 150 ~ 1500Vdc
- FILTER
- Internal capacitor
- EXTERNAL INPUT FUSE
- 4A/1500Vdc, required (Please refer to page 6 for more details)
- INRUSH CURRENT (Typ.)
- Cold start 150A max. @ Vin=800Vdc
OUTPUT
- OUTPUT VOLTAGE
- 48V
- OUTPUT CURRENT
- 0.625A
- EFFICIENCY (Typ.)
- 91%
- CAPACITOR LOAD (MAX.)
- 625μF
- VOLTAGE ACCURACY
- ±2.0%
- RATED POWER
- 30W
- RIPPLE & NOISENote.2
- 12 ~ 24Vo: 100mVp-p 48Vo: 150mVp-p
- LINE REGULATION
- ±1%
- LOAD REGULATION
- ±1% (10% Load to Full Load)
- SWITCHING FREQUENCY (Typ.)
- 28 ~ 75.6KHz
- HOLD UP TIME
- 16ms min. @Vin=800Vdc
- SETUP TIME
- 2s max. @150~1500Vdc
PROTECTION
- SHORT CIRCUIT
- Protection type : Hiccup mode, continuous, automatic recovery
- OVERLOAD
- 110 ~ 300% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- Hiccup mode, recovers automatically after fault condition is removed
- DC INPUT REVERSE POLARITY
- By internal Bridge Diode, no damage, recovers automatically after fault condition removed
- DC INPUT UNDER VOLTAGE LOCKOUT Start-up voltage
- 144Vdc
- DC INPUT UNDER VOLTAGE LOCKOUT Shutdown voltage
- 132Vdc
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +80℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.02% / ℃ (-40℃ ~ 50℃) Typ.
- VIBRATION
- Meets: MIL.STD-810F Table 514.5C-VⅢ, 15-2000Hz, X,Y,Z axis, 1hr (each axis), total 3hrs
- OPERATING ALTITUDENote.3
- 5000 meters
- OVER VOLTAGE CATEGORY
- Ⅱ; According to EN62109-1; altitude up to 5000 meters
SAFETY & EMC
- SAFETY STANDARDS
- UL1741 , CSA C22.2 No.107.1-16 , IEC62109-1 (LVD), EAC TP TC 004 approved
- WITHSTAND VOLTAGE
- I/P-O/P:4KVac
- ISOLATION RESISTANCE
- I/P-O/P, 100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032 Class A (with external components) Radiated BS EN/EN55032 Class A (with external components) - EMC IMMUNITYNote.4
-
BS EN/EN55035
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact, criteria A Radiated Susceptibility BS EN/EN61000-4-3 Level 3, 10V, criteria A EFT/Burest BS EN/EN61000-4-4 Level 2, 0.5KV, criteria A Surge BS EN/EN61000-4-5 Level 4, 2KV/Vin+ ~ Vin-, criteria A Conducted BS EN/EN61000-4-6 Level 3, 10V, criteria A
OTHERS
- MTBF
- 318Khrs MIL-HDBK-217F(25℃)
- DIMENSION (L*W*H)
- P Type: 89*63.5*25mm, ST Type: 135*70*32mm, DR Type: 135*70*43.5mm
- CASE MATERIAL
- Non-conductive black plastic (UL 94V-0 rated)
- POTTING MATERIAL
- UL 94V-0
- PIN MATERIAL
- Base: copper, Plating: Matte Tin
- PACKING
- P Type : 240g ; 6pcs/Tray, 18pcs/per carton ST Type : 305g ; 6pcs/Tray, 18pcs/per carton DR Type : 310g ; 6pcs/Tray, 18pcs/per carton
Test conditions and notes4
- 1. All parameters NOT specially mentioned are measured at 800Vdc input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μf & 47μf parallel capacitor.
- 3. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on http://www.meanwell.com)
Technical drawings
Typical applications
- Photovoltaic power generation
- Renewable Energy System
- High voltage frequency conversion
- Industrial control system
- Semiconductor fabrication equipment
- Electro-mechanical apparatus
- DC bus centralized application
- Energy storage system(ESS)
- Charging pile
- Third rail
Downloads
Datasheet1
FAQ
Can the DDRH-30-48ST supply 48 V power to industrial Ethernet switches or wireless access points in a panel with a high-voltage DC bus?
Yes. The DDRH-30-48ST provides 48 V at 0.625 A (30 W), which covers small industrial Ethernet switches and wireless access points. Its screw terminal connections and 150–1500 VDC input allow direct wiring from a high-voltage DC distribution rail in industrial control panels.
Is this converter suitable for providing 48 V auxiliary power in rail or transit control cabinets?
The DDRH-30-48ST's 150–1500 VDC input range accommodates many high-voltage DC buses used in transit systems. Its –40°C to +80°C operating range (with load derating at higher ambient temperatures per the derating curve) and vibration rating per MIL-STD-810F support use in control cabinets, but the sheet lists no railway-specific standards, so confirm rail compliance requirements separately.
Can the DDRH-30-48ST be used in outdoor enclosures or harsh environments without active cooling?
It can be used inside a protective enclosure. The –40°C to +80°C operating range (with load derating at higher ambient temperatures per the derating curve) covers wide ambient swings in substations, wind farms, and remote monitoring installations, but no IP rating is given and humidity must stay within 20–90% RH non-condensing, so the enclosure must provide environmental protection.
Is the DDRH-30-48ST a good choice for powering 48 V load cells or precision measurement instruments in industrial weighing systems fed from a high-voltage DC rail?
At 48 V / 0.625 A (30 W), the DDRH-30-48ST can supply 48 V instruments and measurement devices with moderate power draws. The screw terminals provide robust wiring connections suitable for industrial measurement environments, and the wide input range supports integration into high-voltage DC-powered weighing system panels.
How does the screw terminal 30 W 48 V model compare to the PCB and DIN rail variants?
All three share 30 W output at 48 V / 0.625 A, 150–1500 VDC input, and –40°C to +80°C operating range. The DDRH-30-48ST (screw terminal) measures 135.0 × 70.0 × 32.0 mm and weighs 0.305 kg; the DDRH-30-48DR (DIN rail) is 135.0 × 70.0 × 43.5 mm at 0.31 kg; the DDRH-30-48P (PCB) is 89.0 × 63.5 × 25.0 mm at 0.24 kg.
What certifications and warranty coverage apply to the DDRH-30-48ST?
The DDRH-30-48ST is approved to UL1741, CSA C22.2 No.107.1-16, IEC62109-1 (LVD) and EAC TP TC 004. The spec sheet does not state a warranty period.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.