Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
XLG-150-12-AB is the 12V output model of this series: rated power 150W, typical efficiency 91.5%.
XLG-150 series is a 150W LED AC/DC driver featuring the constant power mode.XLG-150 operates from 100~305VAC and offers models with different rated current ranging between 700mA and 12500mA. Thanks to the high efficiency up to 93%, with the fanless design, the entire series is able to operate for -40℃~+90℃ case temperature under free air convection. The design of metal housing and IP67 ingress protection level allows this series to fit both indoor and outdoor applications. Moreover the innovative environment-adaptive capability allows this series to reliably light on the LEDs for all kinds of application environments in almost any spots that may install LED luminaires in the world. XLG-150 series comply with the latest version of IEC61347/GB/T19510.1 and UL8750 international safety regulations. The output and dimming circuit are also completely in accordance with the new regulations with isolation to ensure the safety of both user and luminaire system during installation.
Features
- Wide input range 100~305V AC( Class I)
- Full power output at 70~100% Constant power mode operation
- Metal case with IP67, suitable for outdoor application
- Surge protection with 6KV/4KV (10KV/6KV optional)
- 3 in 1 dimming function (Dim to off and Isolation design)
- India (EESL) version with Input Over Voltage Protection can survive input voltage stress of 440Vac for 48 hours
- Protection functions: OVP/SCP/OCP/OTP
- Compliance to EN60335-1 household application
- Life time >50,000 hrs. and 5 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- CONSTANT CURRENT REGIONNote.2
- 8.4~ 12V
- RATED CURRENT (Default)
- 12.5A
- RATED POWER
- 150W
- RIPPLE & NOISE (max.)Note.3
- 150mVp-p
- CURRENT ADJ. RANGE
- Adjustable for A-Type only (via the built-in potentiometer)
- CURRENT ADJ. RANGE
- 6.5~ 12.5A
- VOLTAGE TOLERANCENote.4
- ±3.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±2%
- SETUP, RISE TIMENote.6
- 500ms, 100ms/230VAC, 1200ms, 100ms/115VAC
- HOLD UP TIME (Typ.)
- 10ms/ 230VAC 10ms/ 115VAC
INPUT
- VOLTAGE RANGENote.5
- 100 ~ 305VAC 142 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load
- TOTAL HARMONIC DISTORTION
- THD< 10%(@load≧50%/115VC,230VAC; @load≧75%/277VAC)
- EFFICIENCY (Typ.)
- 91.5%
- AC CURRENT
- 1.8A / 115VAC 1.0A / 230VAC 0.8A/277VAC
- INRUSH CURRENT(Typ.)
- COLD START 50A(twidth=500μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. NO. of PSUs on 16A CIRCUIT BREAKER
- 4 units (circuit breaker of type B) / 8 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- NO LOAD POWER CONSUMPTION
- No load power consumption <0.5W(for standard version)
PROTECTION
- OVER CURRENT
- 110 ~ 160% for CV type, 95~108% for other type; CV-type: Hiccup mode only; Other type: Hiccup or constant current limiting; Recovers automatically after fault condition is removed
- SHORT CIRCUIT
- CV-type: Hiccup mode only; Other type: Hiccup or constant current limiting; Recovers automatically after fault condition is removed
- OVER VOLTAGE
- 13.5 ~ 18V; Shut down output voltage, re-power on to recover
- INPUT OVER VOLTAGE
- 320 ~ 390VAC (Shut down output voltage when the input voltage exceeds protection voltage,recovers automatically after fault condition is removed) Can survive input voltage stress of 440Vac for 48 hours(Input over voltage only for XLG-150I series)
- OVER TEMPERATURE
- Shut down output voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- Tcase=-40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase=+90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.06%/℃ (0 ~ 60℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDSNote.7
- UL8750(type”HL”), UL879,CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384, EN 60335-1 compliant to EN 60335-2-89 Annex BB, EN 60335-2-24 Annex CC;GB/T19510.1,GB/T19510.213;EAC TP TC 004; J61347-1(H29), J61347-2-13 (H29),KC61347-1,KC61347-2-13,IS15885(Part2/Sec13)(for XLG-150I type only);NOM-058-SCFI-2017(except for Blank type);IP67 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 Harmonic Current BS EN/EN61000-3-2 ,GB17625.1 Class C @load≥50% Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN61547
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT/Burst BS EN/EN61000-4-4 Level 3 Surge BS EN/EN61000-4-5 4KV/Line-Line 6KV/Line-Earth(6K/10K option) Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 4 Voltage Dips and Interruptions BS EN/EN61000-4-11 >95% dip 0.5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 2269.5K hrs min. Telcordia SR-332 (Bellcore) ; 213.3Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 180*63*35.5mm (L*W*H)
- PACKING
- 0.8Kg;16pcs/13.4Kg/0.69CUFT
Test conditions and notes16
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Please refer to "DRIVING METHODS OF LED MODULE". (Except for CV-type)
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 4. Tolerance : includes set up tolerance, line regulation and load regulation.
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. Only CE/ENEC/CB is available for CV-type. XLG-150I series without UL/CSA certificate.
- 8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 11. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.
- 13. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 14. To fulfill requirements of the latest ErP regulation for lighting fixture, this LED driver can only be used behind a switch without permanently connected to the mains.
- 15. If you need the NOM (Mexico) certificate, Please contact MEAN WELL sales representative for details.
- 16. For A/AB type need to consider build in using to comply with Type HL application.
Technical drawings
Typical applications
- Skyscraper lighting
- Street lighting
- Floodlight Lighting
- Stagelight
- Horticulture lighting
- Bay lighting
- DMX power supply
- Type HL for use in class I, Division 2
- Household devices
- Retail and refrigerated display
Downloads
FAQ
Can the XLG-150-12-AB power 12V LED strip lighting for retail displays or shelving?
Yes, this model provides 12V output with up to 150W and 12.5A available for compatible LED lighting loads. It is appropriate for 12V strip-based display lighting when the total demand remains within 150W.
Is this driver suitable for 12V channel letters or sign cabinets?
Yes, it can support 12V signage loads that stay within the driver's 150W maximum output. Its IP67 Waterproof rating is also useful for signs exposed to weather.
Can I use the XLG-150-12-AB for 12V LED lighting in outdoor commercial spaces?
For compatible 12V LED loads up to 150W, this driver is suited to outdoor lighting applications because it carries an IP67 Waterproof rating. The -40°C to +90°C operating temperature range supports use in hot and cold conditions.
What LED strip length can I estimate from this 12V 150W driver?
This unit can supply up to 150W at 12V. Estimated strip length equals 150W divided by your strip's watts per meter, so check your strip rated power per meter before sizing the run.
Can this driver be used where rain, dust, or washdown exposure is possible?
Yes, the IP67 Waterproof enclosure is intended for wet and dusty environments rather than dry indoor-only spaces. The metal case and operating range of -40°C to +90°C also support harsher site conditions.
What is the difference between XLG-150-12-AB and nearby XLG 150W siblings?
XLG-150-12-AB and XLG-150-12-A share the same 150W, 12V, 12.5A electrical rating. In the same 150W family, XLG-150-24-A and XLG-150-24-AB are 24V, 6.25A models, and XLG-150-L-A is a constant current model with a 120~214V output range.
Payment & Security
Payment methods