Overview
XLC-40-H-DA2N is the model of this series: rated power 40W, typical efficiency 88%.
XLC-40 Series is a 40W with constant power and constant voltage output LED driver . It can operate from 100~305VAC and output current ranging between 600 mA to 1400 mA selectable by dip switch or NFC setting. Thanks to high efficiency up to 88%, it is able to operate for -25℃~90℃ case temperature under free air convection. XLC-40 is designed based on latest safety regulations with 3 in 1 and DALI-2 dimming. XLC-40 can also be adjusted for brightness with a push button as a simple way dimming, so it provides more flexibility for LED Lighting application.
Features
- Constant power mode output with multiple stage selectable by dip switch or NFC setting (H-type)
- Constant voltage mode output (12V/24V)
- Plastic housing with class II and PFC design
- Meet UL 8750 Class 2 / Class P power unit
- Flicker free, complying with CE ErP directive
- Standby power consumption <0.5W
- Meet emergency lighting (EL) function application
- Minimum dimming level 0.1% (DALI-2 DT6)
- Dimming functions: 3 in 1 dimming (Dim-to-off) DALI-2 + Push dimming
- 5 years warranty
Specifications
OUTPUT
- OPEN CIRCUIT VOLTAGENote.2 (H-type table)
- 60V
- DEFAULT CURRENT
- 1050mA
- CURRENT ADJ.RANGE (BY DIP SWITCH OR NFC)
- 0.6~1.4A
- CONSTANT CURRENT REGIONNote.3 (H-type table)
- 9~54V
- RATED POWERNote.2 (12V/24V table); Note.4 (H-type table)
- 40W
- CURRENT RIPPLE
- <4%(@full load)
- CURRENT TOLERANCE
- ±5%
- DIMMING RANGE
- 0~100%
- SETUP, RISE TIMENote.5 (12V/24V table); Note.5,6 (H-type table)
- 500ms, 100ms/230VAC, 1000ms, 100ms/115VAC
INPUT
- VOLTAGE RANGE
- 100 ~ 305VAC 141 ~ 400VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR
- PF≧0.97/115VAC, PF≧0.95/230VAC, PF≧0.92/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD<10%(@load≧50%/230VAC; @load≧75%/277VAC), THD<15%(@load≧50%/115VAC) (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
- EFFICIENCY (Typ.)Note.7 (H-type table)
- 88%
- AC CURRENT
- 0.5A / 115VAC 0.25A / 230VAC 0.2A/277VAC
- INRUSH CURRENT(Typ.)
- COLD START 10A(twidth=100μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 51 units (circuit breaker of type B) / 51 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- STANDBY POWER CONSUMPTIONNote.8 (H-type table)
- Standby power consumption<0.5W(Dimming off)
PROTECTION
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER TEMPERATURE
- Blank & B type: De-rating to lowest output level. Recovers automatically after fault condition is removed. DA2 type: Stage 1: De-rating to 75% loading; Stage 2: De-rating to 50% loading. Recovers automatically after fault condition is removed.
ENVIRONMENT
- WORKING TEMP.
- Tcase=-25 ~ 90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
- MAX. CASE TEMP.
- Tcase=90℃
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations(DC input 176-280VDC); BS EN/EN62384, BIS IS15885(Part2/Sec13)(NOTE 14), GB/T19510.1, GB/T19510.213, EAC TP TC 004,UL8750(Class P); CSA C22.2 No. 250.13-12 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13
- DALI STANDARDS
- Comply with IEC62386-101,102,207
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC
- ISOLATION RESISTANCE
- I/P-O/P:>100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55015(CISPR15) ,GB/T 17743 Radiated BS EN/EN55015(CISPR15) ,GB/T 17743 Harmonic Current BS EN/EN61000-3-2 , GB17625.1 Class C @load≥50% Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN61547
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact Radiated BS EN/EN61000-4-3 Level 2 EFT/Burst BS EN/EN61000-4-4 Level 2 Surge BS EN/EN61000-4-5 Level 3, 1KV/Line-Line Conducted BS EN/EN61000-4-6 Level 2 Magnetic Field BS EN/EN61000-4-8 Level 2 Voltage Dips and Interruptions BS EN/EN61000-4-11 70% residual voltage for 10 period, 0% residual voltage for 0.5 periods
OTHERS
- FLICKERNote.6 (12V/24V table); Note.9 (H-type table)
- PstLM ≤ 1, SVM ≤ 0.4
- MTBF
- 3935.2 K hrs min. Telcordia SR-332 (Bellcore) ; 342.9 Khrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 147*40*32mm,107*40*32mm (L*W*H)
- PACKING
- 193g; 60pcs/12.58Kg/0.58CUFT(for blank type); 210g; 50pcs/11.5Kg/0.57CUFT(for S-type)
Test conditions and notes14
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. De-rating may be need under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 3. Ripple & noise are measured at 20MHz of bandwidth by using a 12” twisted pair-wire terminated with a 0.1uF & 47uF parallel capacitor.
- 4. Tolerance: includes set up tolerance, line regulation and load regulation.
- 5. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 6. Flicker is measured at full load with the light source provided by MEAN WELL.
- 7. To fulfill requirement of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- 8. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 9. The ambient temperature de-rating of 3.5℃/1000m with fanless models and 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 10. This series meets the typical life expectancy of >50,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 11. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
- 12. Products sourced from the Americas regions may not have the CCC/PSE/BIS/KC logo. Please contact your MEAN WELL sales for more information.
- 13. For more information, please contact with MEAN WELL sales.
- 14. Products sourced from the China regions and some models sourced from India may not have the BIS logo,please refer to BIS certificate for details and contact your MEAN WELL sales for more information.
Technical drawings
Typical applications
- Recessed Light
- Down Light
- Panel Light
- Commercial Lighting
- Decorative Lighting
- LED strip lighting
- DALI digital Lighting
Downloads
::specification::
FAQ
Can I program the output current on the XLC-40-H-DA2N after the luminaire is installed?
Yes. The -N suffix indicates NFC current setting, allowing output current to be adjusted between 0.6A and 1.4A wirelessly through the luminaire housing using a compatible NFC programmer. This eliminates the need to access the dip switch once the fixture is in place.
Is the XLC-40-H-DA2N suitable for DALI2-controlled LED downlights in smart building projects?
Yes. It supports DALI2 and push dimming with a minimum dimming level of 0.1%, and NFC current setting simplifies post-installation commissioning. The 40W, 1050mA constant current output with flicker-free operation is appropriate for recessed or built-in commercial downlights.
Can I use the XLC-40-H-DA2N for LED modules in retail track or accent lighting with a DALI2 controller?
Yes. DALI2 support enables individual addressing and smooth dimming to 0.1%, which is useful in retail environments requiring precise accent-light level control. The built-in form factor requires mounting inside the luminaire enclosure.
How does the XLC-40-H-DA2N differ from the XLC-40-H-DA2 in current configuration?
Both models share the same 40W output, 1050mA nominal current, DALI2 dimming, and 0.6–1.4A adjustment range. The XLC-40-H-DA2 uses a dip switch for current setting, while the XLC-40-H-DA2N uses NFC. Choose -DA2N when the driver will be sealed inside a luminaire after installation.
What CC voltage range should my LED string meet for the XLC-40-H-DA2N?
The constant current output operates between 9V and 54V. LED strings must be sized so their total forward voltage at the selected drive current falls within this range. The number of series LEDs varies by LED type and its forward voltage at the operating current.
What is the operating temperature range of the XLC-40-H-DA2N and is it suitable for harsh indoor environments?
The driver is rated from -25°C to +90°C case temperature and carries ENEC, UL8750 Class P, CSA, and EAC certifications. It is specified for built-in use, so it must be housed in a suitable enclosure. For installations in high-ambient environments, ensure the luminaire enclosure provides adequate thermal dissipation.
Payment & Security