Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
PLP-30-12 is the 12V output model of this series: rated current 2.5A, rated power 30W, typical efficiency 83%.
Features
- Universal AC input / Full range
- Protections: Short circuit / Over current / Over voltage
- Built-in active PFC function
- Cooling by free air convection
- Class 2 power unit
- Output current level adjustable
- 100% full load burn-in test
- High reliability
- Suitable for built-in applications of LED lighting
- 2 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- CONSTANT CURRENT REGIONNote.5
- 9 ~ 12V
- RATED CURRENT
- 2.5A
- CURRENT RANGE
- 0 ~ 2.5A
- RATED POWER
- 30W
- RIPPLE & NOISE (max.)Note.2
- 2Vp-p
- CURRENT ADJ. RANGE
- 1.875 ~ 2.5A
- VOLTAGE TOLERANCENote.3
- ±10%
- LINE REGULATION
- ±3.0%
- LOAD REGULATION
- ±5.0%
- SETUP TIME
- 500ms / 230VAC 1200ms / 115VAC at full load
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.9 at 75 ~ 100% load , 115VAC / 230VAC
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≥75% at 115VAC/230VAC input
- EFFICIENCY (Typ.)
- 83%
- AC CURRENT (Typ.)
- 0.4A/115VAC 0.2A/230VAC
- INRUSH CURRENT (max.)
- COLD START 25A(twidth=45μs measured at 50% Ipeak) at 230VAC
- MAX.No. of PSUs on 16A CIRCUIT BREAKER
- 64units (circuit breaker of type B) / 64 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVER CURRENTNote.5
- 100 ~ 110% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed.
- OVER VOLTAGE
- 15 ~ 18V Protection type : Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- GB/T19510.1,GB/T19510.213,UL8750, TUV BS EN/EN61347-1, BS EN/EN61347-2-13, CSA C22.2 No. 250.0-08(except for 48V),EAC TP TC 004 approved ; design refer to UL60950-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to GB/T 17743, GB17625.1,BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧75% load); BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035,BS EN/EN61547, light industry level, EAC TP TC 020
OTHERS
- MTBF
- 5126.3K hrs min. Telcordia SR-332 (Bellcore) ; 580.9K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 101.6*50.8*26.6mm (L*W*H)
- PACKING
- 0.12Kg; 108pcs/13Kg/0.89CUFT
Test conditions and notes10
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltage. Please check the static characteristics for more details.
- 5. Please refer to "DRIVING METHODS OF LED MODULE".
- 6. The power supply is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. Heat Sink HS1,HS2 can not be shorted.
- 8. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
- 9. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 10. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
Technical drawings
Downloads
Datasheet1
FAQ
What is the Mean Well PLP-30-12 used for?
The Mean Well PLP-30-12 is a 30W single-output LED power supply designed as a component for installation in LED lighting fixtures and equipment. It provides a 12V output and is suited to commercial or OEM use where a compact 101.6 x 50.8 x 26.6mm power unit is needed.
What are the main electrical ratings of the PLP-30-12?
This model is rated for 30W total output power with a 12V output and 2.5A rated current. It accepts a universal AC input range of 90 to 264VAC and also supports 127 to 370VDC input.
Is the PLP-30-12 dimmable?
No dimming function is listed on the datasheet for the PLP-30-12. Its output current can only be set within the 1.875 to 2.5A adjustment range rather than by integrated dimming control.
Does the PLP-30-12 include protection features?
Yes, this model includes protection for short circuit, over current and over voltage (15 to 18V) conditions. These built-in protections help support reliability in LED lighting applications.
Can the output current be adjusted on the PLP-30-12?
Yes, the output current level is adjustable on this model. The listed adjustment range is 1.875 to 2.5A, which is 75% to 100% of rated current.
What operating temperatures can the PLP-30-12 handle?
The PLP-30-12 is specified for operation from -30°C to 70°C, with load derating at higher ambient temperatures according to the derating curve. That range makes it suitable for a wide variety of indoor equipment and enclosed lighting applications, provided the overall system is designed within the product limits.
How does the PLP-30-12 support long-term reliability?
This model features PFC (PF>0.9 at 75 to 100% load) and over current, short circuit and over voltage protection. Mean Well lists an MTBF of 580.9K hours min. under MIL-HDBK-217F at 25°C, and 5126.3K hours min. under Telcordia SR-332.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.