Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well XLC-60-48-MA LED Driver 60W 48V Constant Voltage LED Driver, Matter Wireless Dimming 1.25A

$170.10 USD
Shipping calculated at checkout.

|

Your order will be processed within 24 hours

Overview

XLC-60-48-MA is the 48V output model of this series: rated power 60W, typical efficiency 88%.

XLC-60-MA series is a 60W with constant power and constant voltage output LED driver . It can operate from 100~305V AC and output current ranging between 900 mA to 1700 mA selectable by DIP switch. Thanks to high efficiency up to 90%, it is able to operate for -25℃ ~90℃ case temperature under free air convection. XLC-60-MA series is designed based on latest safety regulations with matter wireless dimming .It provides more flexibility for LED Lighting application.

Features

  • Constant power mode output with multiple stage selectable by DIP switch (H-type)
  • Constant voltage mode output(12/24/48V)
  • Plastic housing with class Ⅱ and PFC design
  • Flicker free, complying with CE ErP directive
  • Standby power consumption <0.5W
  • Meet emergency lighting (EL) application
  • Minimum dimming level 0.1% (12/24/48V)
  • Minimum dimming level 0.5% (H-type)
  • Matter over thread, Matter 1.3 specification
  • 5 years warranty

Specifications

XLC-60-48-MASpecifications from the official datasheet (2025-03-11 edition)

OUTPUT

DC VOLTAGE
48V
DEFAULT CURRENT
1.25A
RATED POWERNote.2 (12/24/48V), Note.4 (H)
60W
SETUP, RISE TIMENote.3 (12/24/48V), Note.6 (H)
2500ms,180ms/230VAC ,2500ms,180ms/115VAC

INPUT

VOLTAGE RANGE
100~305VAC 155~400VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR
PF≥0.95/115VAC, PF≥0.95/230VAC, PF≥0.9/277VAC@full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
TOTAL HARMONIC DISTORTION
THD< 20%(@load ≥60%/230VAC; @load ≥75%/277VAC); THD<10%@load 100%/230VAC (Please refer to “TOTAL HARMONIC DISTORTION(THD)” section)
EFFICIENCY(Typ.)Note.7 (H)
88%
AC CURRENT
0.75A/115VAC, 0.35A/230VAC, 0.3A/277VAC
INRUSH CURRENT
COLD START 15A(twidth=310μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
MAX. NO. of PSUs on 16A CIRCUIT BREAKER
25 units (circuit breaker of type B) / 36 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC
STANDBY POWER CONSUMPTIONNote.4 (12/24/48V), Note.9 (H)
Standby power consumption<0.5W (Dimming off)

PROTECTION

OVERLOAD
105~200% rated output power; Protection type: Hiccup mode, recovers automatically after fault condition is removed.
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
52~63V; Shut down output voltage, re-power on to recover
OVER TEMPERATURE
Shut down output voltage, recovers automatically after fault condition is removed

ENVIRONMENT

WORKING TEMP.
Tcase=-25~90℃ (Please refer to “ OUTPUT LOAD vs TEMPERATURE” section)
MAX. CASE TEMP.
Tcase=90℃
WORKING HUMIDITY
20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13(EL) appendix J suitable for emergency installations (DC input 176-280VDC); BS EN/EN62384 , GB/T 19510.1, GB/T 19510.213, EAC TP TC 004 approved; Design refer to AS/NZS 61347-1, AS/NZS 61347-2-13
WITHSTAND VOLTAGE
I/P-O/P: 3.75KVAC
ISOLATION RESISTANCE
I/P-O/P: >100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
ConductedBS EN/EN55015(CISPR15) ,GB/T 17743
RadiatedBS EN/EN55015(CISPR15) ,GB/T 17743
Harmonic CurrentBS EN/EN61000-3-2 , GB17625.1Class C @load≥60%
Voltage FlickerBS EN/EN61000-3-3
EMC IMMUNITY

BS EN/EN61547

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 3, 8KV air; Level 2, 4KV contact
RadiatedBS EN/EN61000-4-3Level 2
EFT/BurstBS EN/EN61000-4-4Level 2
SurgeBS EN/EN61000-4-5Level 3, 1KV/Line-Line
ConductedBS EN/EN61000-4-6Level 2
Magnetic FieldBS EN/EN61000-4-8Level 2
Voltage Dips and InterruptionsBS EN/EN61000-4-1170% residual voltage for 10 period, 0% residual voltage for 0.5 periods

OTHERS

MATTER STANDARD
Matter 1.3 Specification
FLICKERNote.7 (12/24/48V), Note.10 (H)
PstLM ≤ 1, SVM ≤ 0.4
MTBF
4130.5K hrs min. Telcordia SR-332 (Bellcore) 317.7Khrs min. MIL-HDBK-217F (25℃)
DIMENSION
176*45*32mm , 136*45*32mm (L*W*H)
PACKING
0.28Kg; 40pcs/12Kg/0.48CUFT(for Blank type); 0.30Kg; 40pcs/13Kg/0.63CUFT(for S-type);
Test conditions and notes14
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
  2. 2. Output hiccups under no-load condition.
  3. 3. Please refer to “DRIVER METHODS OF LED MODULE”.
  4. 4. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
  5. 5. Current ripple is measured 50%~100% of maximum voltage under rated power delivery.
  6. 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
  7. 7. Efficiency is measured at 1050mA/54V output set by DIP switch.
  8. 8. For XLC-S series: RCM is on a voluntary basis. Non IC classification Independent LED control gear is not suitable for residential installations. For XLC(except -S) series: RCM is on a voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
  9. 9. Standby power consumption is measured at 230VAC.
  10. 10. Flicker is measured at full load with the light source provided by MEAN WELL.
  11. 11. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  12. 12. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  13. 13. This series meets the typical life expectancy of 50000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about75℃ or less.
  14. 14. For more information, please contact with MEAN WELL sales.

Technical drawings

XLC-60-48-MA BLOCK DIAGRAM
BLOCK DIAGRAM
XLC-60-48-MA DRIVING METHODS OF LED MODULE
DRIVING METHODS OF LED MODULE
XLC-60-48-MA PWM OUTPUT DIMMING PRINCIPLE
PWM OUTPUT DIMMING PRINCIPLE
XLC-60-48-MA OUTPUT LOAD vs TEMPERATURE
OUTPUT LOAD vs TEMPERATURE
XLC-60-48-MA STATIC CHARACTERISTIC
STATIC CHARACTERISTIC
XLC-60-48-MA TOTAL HARMONIC DISTORTION (THD)
TOTAL HARMONIC DISTORTION (THD)
XLC-60-48-MA POWER FACTOR (PF) CHARACTERISTIC
POWER FACTOR (PF) CHARACTERISTIC
XLC-60-48-MA EFFICIENCY vs LOAD
EFFICIENCY vs LOAD
XLC-60-48-MA MECHANICAL SPECIFICATION
MECHANICAL SPECIFICATION
XLC-60-48-MA ※ By RESET BUTTON
※ By RESET BUTTON
XLC-60-48-MA Phase
Phase
XLC-60-48-MA Antenna location
Antenna location

Typical applications

  • Recessed Light
  • Down Light
  • Panel Light
  • Commercial Lighting
  • Decorative Lighting
  • LED strip lighting
  • Matter wireless Lighting

Downloads

FAQ

Can I control the XLC-60-48-MA wirelessly from a smartphone or smart home hub?

Yes, the XLC-60-48-MA supports Matter 1.3, which allows wireless dimming control from any Matter-compatible app, hub, or voice assistant. It can dim down to a minimum level of 0.1%, providing smooth, full-range control over connected 48V LED strips or fixtures.

Is the XLC-60-48-MA compatible with Apple Home, Amazon Alexa, or Google Home ecosystems?

Matter 1.3 — the protocol built into the XLC-60-48-MA — is supported by Apple Home, Amazon Alexa, Google Home, and other major smart home platforms. A Matter-compatible hub or border router on the same network is typically required to bridge the driver into these ecosystems.

Can the XLC-60-48-MA power a 48V LED strip for cove or architectural lighting in a smart home setup?

The XLC-60-48-MA is a practical choice for cove or architectural lighting where tunable brightness is desired. It delivers 60W at 48V and dims to 0.1% via Matter wireless, allowing scene-based or occupancy-driven control without a separate dimmer module or additional wiring.

How much 48V LED strip can the XLC-60-48-MA drive?

The XLC-60-48-MA outputs a maximum of 60W at 48V and 1.25A. Divide 60W by your strip's wattage per meter to find the maximum run length — a 10W/m strip supports up to 6 meters, and a 15W/m strip supports up to 4 meters. Always check your strip's rated power per meter to confirm compatibility.

Does the XLC-60-48-MA work at 100VAC input, such as in Japan or parts of the US on lower-voltage circuits?

Yes, the XLC-60-48-MA accepts input from 100 to 305VAC, making it compatible with 100VAC supply found in Japan and select other markets, as well as standard 120VAC, 220VAC, and 230VAC mains.

Can the XLC-60-48-MA be installed inside a recessed lighting enclosure or luminaire housing?

The XLC-60-48-MA is a Class II driver designed for built-in installation. Its compact 136mm body length makes it easier to fit inside tight luminaire housings compared to the 176mm siblings. It operates from -25°C to +90°C, which covers typical temperatures inside enclosed fixtures.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • PayPal
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":9757419798848, "variants" :[{ "context":"default", "variant_id": 50423557226816, "sku":"XLC-60-48-MA", "inventory_qty" : 0, "customer" : true, "custom_html" :"\u003cdiv class=\"price\"\u003e\n \u003cdiv class=\"price__default\"\u003e\n \u003cstrong class=\"price__current\"\u003e$170.10\u003c\/strong\u003e\n \u003cs class=\"price__was\"\u003e\u003c\/s\u003e\n \u003c\/div\u003e\n\n \u003cdiv class=\"unit-price relative\" hidden\u003e\u003cspan class=\"visually-hidden\"\u003eUnit price\u003c\/span\u003e\u003cspan class=\"unit-price__price\"\u003e\u003c\/span\u003e\u003cspan class=\"unit-price__separator\"\u003e \/ \u003c\/span\u003e\u003cspan class=\"unit-price__unit\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv class=\"price__no-variant\" hidden\u003e\n \u003cstrong class=\"price__current\"\u003eUnavailable\u003c\/strong\u003e\n \u003c\/div\u003e\n\n \u003c\/div\u003e\n", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well XLC-60-48-MA LED Driver 60W 48V Constant Voltage LED Driver, Matter Wireless Dimming 1.25A
Mean Well

Mean Well XLC-60-48-MA LED Driver 60W 48V Constant Voltage LED Driver, Matter Wireless Dimming 1.25A

$170.10 USD

XLC-60-48-MA is the 48V output model of this series: rated power 60W, typical efficiency 88%.

XLC-60-MA series is a 60W with constant power and constant voltage output LED driver . It can operate from 100~305V AC and output current ranging between 900 mA to 1700 mA selectable by DIP switch. Thanks to high efficiency up to 90%, it is able to operate for -25℃ ~90℃ case temperature under free air convection. XLC-60-MA series is designed based on latest safety regulations with matter wireless dimming .It provides more flexibility for LED Lighting application.

Features

  • Constant power mode output with multiple stage selectable by DIP switch (H-type)
  • Constant voltage mode output(12/24/48V)
  • Plastic housing with class Ⅱ and PFC design
  • Flicker free, complying with CE ErP directive
  • Standby power consumption <0.5W
  • Meet emergency lighting (EL) application
  • Minimum dimming level 0.1% (12/24/48V)
  • Minimum dimming level 0.5% (H-type)
  • Matter over thread, Matter 1.3 specification
  • 5 years warranty

Typical applications

  • Recessed Light
  • Down Light
  • Panel Light
  • Commercial Lighting
  • Decorative Lighting
  • LED strip lighting
  • Matter wireless Lighting
View product