Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLG-480H-48AB is the 48V output model of this series: rated current 10A, rated power 480W, typical efficiency 94.5%.
HLG-480H series is a 480W AC/DC LED driver featuring the dual mode constant voltage and constant current output. HLG-480H operates from 90~305VAC and offers models with different rated voltage ranging between 24V and 54V. Thanks to the high efficiency up to 95.5%, with the fanless design, the entire series is able to operate for -40℃ ~ +90℃ case temperature under free air convection. The design of metal housing and IP67/IP65 ingress protection level allows this series to fit both indoor and outdoor applications.HLG-480H is equipped with various function options, such as dimming methodologies, so as to provide the optimal design flexibility for LED lighting system.
Features
- Constant Voltage + Constant Current mode output
- Metal housing with class I design
- Built-in active PFC function
- IP67 / IP65 design for indoor or outdoor installations
- Function options: output adjustable via potentiometer; 3 in 1 dimming (dim-to-off, isolated design) ; smart timer dimming; junction box
- Typical lifettime > 62000 hours
- 7 years warranty (Note.9)
Specifications
OUTPUT
- DC VOLTAGE
- 48V
- CONSTANT CURRENT REGIONNote.4
- 24 ~ 48V
- RATED CURRENT
- 10A
- RATED POWER
- 480W
- RIPPLE & NOISE (max.)Note.2
- 250mVp-p
- VOLTAGE ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 40.8 ~ 50.4V
- CURRENT ADJ. RANGE
- Adjustable for A/AB-Type only (via built-in potentiometer) 5 ~ 10A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 500ms, 80ms 115VAC/230VAC
- HOLD UP TIME (Typ.)
- 16ms 115VAC/230VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC (Please refer to "STATIC CHARACTERISTIC" section)
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≧0.98/115VAC, PF≧0.97/230VAC, PF≧0.95/277VAC @ full load (Please refer to "POWER FACTOR (PF) CHARACTERISTIC" section)
- TOTAL HARMONIC DISTORTION
- THD< 20% (@ load≧40% / 115VAC,230VAC,277VAC) (Please refer to "TOTAL HARMONIC DISTORTION (THD)" section)
- EFFICIENCY (Typ.) 230VAC
- 94.5%
- EFFICIENCY (Typ.) 277VAC
- 95%
- AC CURRENT (Typ.)
- 5A / 115VAC 2.45A / 230VAC 2A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 35A(twidth=1800μs measured at 50% Ipeak) at 230VAC; Per NEMA 410
- LEAKAGE CURRENT
- <0.75mA / 277VAC
- MAX. NO. of PSUs on 16A CIRCUIT BREAKER
- 2unit(circuit breaker of type B) / 3units(circuit breaker of type C) at 230VAC
PROTECTION
- OVER CURRENT
- 95 ~ 108% Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Constant current limiting, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 53 ~ 63V Shut down output voltage, re-power on to recovery
- OVER TEMPERATURE
- Shut down output voltage, re-power on to recovery
ENVIRONMENT
- WORKING TEMP.
- Tcase= -40 ~ +90℃ (Please refer to "OUTPUT LOAD vs TEMPERATURE" section)
- MAX. CASE TEMP.
- Tcase= +90℃
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.02%/℃ (0 ~ 60℃)
- VIBRATION
- 10 ~ 500Hz, 5G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750(type"HL"), CSA C22.2 No. 250.13-12; ENEC BS EN/EN61347-1, BS EN/EN61347-2-13 independent, BS EN/EN62384; GB/T19510.1,GB/T19510.213;IP65 or IP67, EAC TP TC 004,AS/NZS IEC 61347.2.13:2013,AS/NZS 61347.1:2016;KC61347-1, KC61347-2-13(except for AB,Dx type), J61347-1(H29), J61347-2-13(H29)(except for Dx type)approved
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (@ load≧50%) ; BS EN/EN61000-3-3;GB/T 17743, GB17625.1, EAC TP TC 020;KC KN15,KN61547(except for AB,Dx type),J55015(H29)(for Blank/A-type)
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, light industry level (surge immunity Line-Earth 4KV, Line-Line 2KV), EAC TP TC 020 ;KC KN15,KN61547( except for AB,Dx type ),J55015(H29)(for Blank/A-type)
OTHERS
- MTBF
- 1185.9K hrs min. Telcordia SR-332(Bellcore) ; 95.4K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 262*125*43.8mm (L*W*H)
- PACKING
- 2.8Kg;4pcs/12.2Kg/0.55CUFT
Test conditions and notes13
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated current and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. De-rating may be needed under low input voltages. Please refer to “STATIC CHARACTERISTIC” sections for details.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the driver may lead to increase of the set up time.
- 7. The driver is considered as a component that will be operated in combination with final equipment. Since EMC performance will be affected by the complete installation, the final equipment manufacturers must re-qualify EMC Directive on the complete installation again. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED driver can only be used behind a switch without permanently connected to the mains.
- 9. This series meets the typical life expectancy of >62,000 hours of operation when Tcase, particularly tc point (or TMP, per DLC), is about 75℃ or less.
- 10. Please refer to the warranty statement on MEAN WELL's website at http://www.meanwell.com
- 11. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 12. For any application note and IP water proof function installation caution, please refer our user manual before using. https://www.meanwell.com/Upload/PDF/LED_EN.pdf
- 13. For A/AB type need to consider build in using to comply with Type HL application.
Technical drawings
Typical applications
- LED Harboure
- LED greenhouse lighting
- LED statium lighting
- LED mining lighting
- Type "HL" for use in ClassⅠ,Division 2 hazardous(Classified) location
Downloads
Certificates10
Test reports1
Catalogues1
FAQ
Can I use the HLG-480H-48AB to power a large 48V LED strip installation with dimming?
Yes. The HLG-480H-48AB delivers 480W at 48V and includes both an output adjustment potentiometer and a 3-in-1 dimming input (0-10VDC, 10V PWM or resistance). This makes it well suited for lengthy 48V LED strip runs in commercial or architectural projects where brightness control is required.
Is the HLG-480H-48AB suitable for powering 48V LED signage with brightness scheduling?
Yes. With 480W of output at 48V and built-in dimming capability, this driver can handle large channel letter signs or illuminated sign cabinets running on 48V LED modules. The dimming input allows connection to a timer or automation controller for day/night brightness scheduling.
Can the HLG-480H-48AB drive 48V LED high-bay or warehouse lighting?
Yes. At 480W and 10A of output current, the HLG-480H-48AB can power high-output 48V LED fixtures used in warehouses or industrial spaces. The adjustable output lets you fine-tune voltage to match your fixture string, and the dimming input supports occupancy-based or daylight-harvesting dimming.
How many meters of 48V LED strip can the HLG-480H-48AB support?
That depends on the strip's rated power per meter. The HLG-480H-48AB supplies up to 480W at 48V. For example, a strip rated at 20W/m could run up to 24 meters (480W / 20W per meter = 24m). Always check your strip's rated power per meter and keep total load at or below 480W.
Can the HLG-480H-48AB be mounted in a covered outdoor location?
Yes. Its IP65 rating protects against dust ingress and low-pressure water jets, so it is suitable for covered patios, soffits, or ventilated outdoor enclosures. For fully exposed installations or locations with a risk of temporary immersion, consider the IP67-rated HLG-480H-48B instead.
What are the differences between the HLG-480H-48, 48A, 48AB, and 48B?
All four share the same 480W / 48V / 10A core specs and metal housing. The base HLG-480H-48 has no output adjustment or dimming and is IP67 waterproof. The -48A adds an output adjustment potentiometer (IP65). The -48AB adds both adjustment and 0-10V/PWM/resistance dimming (IP65). The -48B provides dimming input only and retains IP67 waterproofing.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HLG-480H Models
1 other model| Model | Power | Voltage | Current | IP Rating | |
|---|---|---|---|---|---|
| Mean Well HLG-480H-24B Power Supply 480W 24V- Dimmable 20A | 480W | 24V | 20A | IP67 | View |