Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
EPS-15-24 is the 24V output model of this series: rated current 0.625A, rated power 15W, typical efficiency 83%.
Features
- Universal AC input / Full range
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- 1.8"x2.5" compact size
- No load power consumption<0.3W
- Operating altitude up to 3000 meters
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 0.625A
- CURRENT RANGE
- 0 ~ 0.69A
- RATED POWER
- 15W
- PEAK LOAD(10sec.)Note.6
- 16.56W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 21.6 ~ 27V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 30ms/230VAC 2000ms, 30ms/115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms/230VAC 16ms/115VAC at full load
INPUT
- VOLTAGE RANGENote.5
- 85 ~ 264VAC 120 ~ 370VDC [DC input operation possible by connecting AC/N(+), AC/L(-)]
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 83%
- AC CURRENT (Typ.)
- 0.4A/115VAC 0.2A/230VAC
- INRUSH CURRENT (Typ.)
- COLD START 45A/230VAC
- LEAKAGE CURRENT
- <1mA/240VAC
PROTECTION
- OVER LOAD
- 115 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 27.6 ~ 33V Protection type : Shut down o/p voltage, Clamping by zener diode
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- OPERATING ALTITUDENote.7
- 3000 meters
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
SAFETY & EMC (Note 4)
- SAFETY STANDARDS
- UL62368-1, TUV BS EN/EN62368-1, EAC TP TC 004, CCC GB4943.1 approved
- WITHSTAND VOLTAGE
- I/P-O/P:3KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55032 (CISPR32) Class B, BS EN/EN61000-3-2,-3, EAC TP TC 020, GB9254 Class B, GB17625.1
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN55035, heavy industry level, EAC TP TC 020
OTHERS
- MTBF
- 6024.7K hrs min. Telcordia SR-332 (Bellcore) ; 849.3K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 63.5*45.7*24mm (L*W*H)
- PACKING
- 0.057Kg; 120pcs/ 7.84Kg/0.94CUFT
Test conditions and notes7
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
- 5. Derating may be needed under low input voltage. Please check the static characteristics for more details.
- 6. 33% Duty cycle maximum within every 30 seconds. Average output power should not exceed the rated power.
- 7. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
Technical drawings
Downloads
Datasheet1
Certificates9
Test reports1
Catalogues1
FAQ
Can I use the EPS-15-24 for a 24V PLC input or small automation device?
Yes, if the equipment needs 24V constant voltage and the load stays within 0.625A and 15W. That makes it a fit for lighter 24V control and automation loads rather than higher-current devices.
Is the EPS-15-24 suitable for 24V sensors, relays, or interface modules?
It can work for compact 24V accessories that do not exceed 0.625A. Buyers should check total current draw carefully because this is a 15W model, not a higher-capacity 24V supply.
Can this model power a low-power 24V embedded system?
Yes, for embedded or control electronics designed for a fixed 24V rail and modest power demand. Its 63.5 x 45.7 x 24.0 mm dimensions also support tighter packaging.
Is the EPS-15-24 meant for indoor or outdoor use?
The temperature specification is -30°C to +70°C, with output derating at higher temperatures per the derating curve, so it can operate across a broad temperature range. No IP rating is provided, so it should be treated as a supply for protected indoor use or for installation inside a suitable enclosure.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.