Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
IRM-45-24 is the 24V output model of this series: rated current 1.9A, rated power 45.6W, typical efficiency 89.5%. Type Blank: PCB mounting style.
IRM-45 is a 45W miniature (87*52*29.5mm) AC-DC module-type power supply, ready to be soldered onto the PCB boards of various kinds of electronic instruments or industrial automation equipments. This product allows the universal input voltage range of 85~305Vac. The 94V-0 flame retardant plastic case and potted with silicone enhance the heat dissipation. PCB mounting style model(Blank) meet the anti-vibration demand up to 2G and screw terminal style model (ST) meet the anti-vibration demand up to 5G; moreover, it provides the fundamental resistance to dust and moisture. With the high efficiency up to 90.5% and the extremely low no-load power consumption below 0.15W, IRM-45 series fulfills the worldwide regulation for the low power consumption requirement for electronics. The entire series is a Class Ⅱ design (no FG pin), incorporating the built-in EMI filtering components, enabling the compliance with BS EN/EN55032 Class B; the supreme EMC features keep the end electronic units from electromagnetic interference. In addition to the PCB mounting style model, IRM-45 series also offers the screw terminal style model (ST).
Features
- 3.43''x2.05''compact size
- PCB,chassis or screw terminal mounting version
- Universal input 85~305Vac
- No load power consumption<0.15W
- EMI Class B without additional components
- Wide operating temp. range -30~85℃
- Protections: Short circuit / Overload / Over voltage
- Cooling by free air convection
- Isolation Class Ⅱ
- Over voltage category Ⅲ (OVC Ⅲ)
- Pass LPS(Except for 5V)
- 3 years warranty
Model encoding
| Type | Function |
|---|---|
| Blank (this model) | PCB mounting style |
| ST | Screw terminal style |
Specifications
OUTPUT
- DC VOLTAGE
- 24V
- RATED CURRENT
- 1.9A
- CURRENT RANGE
- 0 ~ 1.9A
- RATED POWER
- 45.6W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE TOLERANCENote.3
- ±2.5%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 30ms/230Vac 2000ms, 30ms/115Vac at full load
- HOLD UP TIME (Typ.)
- 50ms/230Vac 12ms/115Vac at full load
INPUT
- VOLTAGE RANGE
- 85 ~ 305Vac
- FREQUENCY RANGE
- 47 ~ 440Hz
- EFFICIENCY (Typ.)
- 89.5%
- AC CURRENT (Typ.)
- 1.5A/115Vac 0.9A/230Vac 0.75A/277Vac
- INRUSH CURRENT (Typ.)
- COLD START 30A/115Vac 60A/230Vac
- LEAKAGE CURRENT
- < 0.25mA/277Vac
PROTECTION
- OVERLOAD
- 115%~160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 25.2 ~ 32.4V Protection type : Shut off o/p voltage, clamping by zener diode
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +85℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- Blank:10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes ST:10 ~ 500Hz, 5G 10min./1cycle, period for 60min. each along X, Y, Z axes
- SOLDERING TEMPERATURE
- Wave soldering: 265℃,5s (max.); Manual soldering: 390℃,3s (max.)
- OPERATING ALTITUDENote.4
- 2000 meters
SAFETY & EMC
- SAFETY STANDARDS
- IEC62368-1,IEC61558-1/-2-16,UL62368-1,TUV BS EN/EN62368-1,BS EN/EN60335-1,BS EN/EN61558-1/-2-16, EAC TP TC 004, BSMI CNS15598-1 approved
- OVER VOLTAGE CATEGORY
- IEC/EN 61558-1/-2-16(OVC Ⅲ, altitude up to 2000m); IEC/EN/UL 62368-1(OVC Ⅲ, altitude up to 2000m); IEC/EN 60335-1(OVC Ⅱ,altitude up to 2000m)
- WITHSTAND VOLTAGE
- I/P-O/P:4.2KVac
- ISOLATION RESISTANCE
- I/P-O/P:100M Ohms / 500Vdc / 25℃/ 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted BS EN/EN55032(CISPR32), CNS15936 Class B Radiated BS EN/EN55032(CISPR32), CNS15936 Class B Harmonic Current (Note 5) BS EN/EN61000-3-2 Class A Voltage Flicker BS EN/EN61000-3-3 - EMC IMMUNITYNote.5
-
BS EN/EN55035, BS EN/EN61000-6-2
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 3, 8KV air; Level 2, 4KV contact, criteria A Radiated Susceptibility BS EN/EN61000-4-3 Level 3, criteria A EFT/Burest BS EN/EN61000-4-4 Level 3, criteria A Surge BS EN/EN61000-4-5 Level 4, 2KV/L-N, criteria A Conducted BS EN/EN61000-4-6 Level 3, criteria A Magnetic Field BS EN/EN61000-4-8 Level 4, criteria A Voltage Dips and interruptions BS EN/EN61000-4-11 >95% dip 0. 5 periods, 30% dip 25 periods, >95% interruptions 250 periods
OTHERS
- MTBF
- 6451.1K hrs min. Telcordia SR-332 (Bellcore) ; 1212.1K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- PCB mounting style : 87*52*29.5mm (L*W*H) Screw terminal style : 109*52*33.5mm (L*W*H)
- PACKING
- PCB mounting style : 0.195Kg;60pcs/12.7Kg/0.94CUFT Screw terminal style :0.228Kg; 50pcs/12.4Kg/0.56CUFT
Test conditions and notes5
- 1. All parameters NOT specially mentioned are measured at 230Vac input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1μF & 47μF parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 5. The power supply is considered as an independent unit ,but the final equipment still need to re-confirm that the whole system complieswith the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Typical applications
- Industrial electrical equipment
- Mechanical equipment
- Factory automation equipment
- Handheld electronic device
Downloads
Datasheet1
Certificates4
Test reports1
Catalogues1
FAQ
Can I use the IRM-45-24 for a 24V PLC, sensor, or industrial I/O circuit?
Yes, if the load requires constant voltage 24V and stays within 1.9A and 45.6W, this model is electrically suitable. That makes it relevant for 24V control and interface loads commonly used in industrial automation equipment.
Is the IRM-45-24 suitable for 24V embedded or instrumentation electronics inside OEM equipment?
It can be used for 24V constant voltage electronics up to 45.6W total output. The miniature encapsulated body and PCB mounting style make it better suited to internal equipment integration than exposed field placement.
Can this model power 24V automation accessories in a compact control cabinet?
Yes, it is designed to deliver 24V DC at up to 1.9A, which fits many smaller automation accessory loads. Its 85-305VAC input range is also useful where the same product may be deployed across different AC mains conditions.
How does the IRM-45-24 compare with other IRM-45 power levels and outputs?
The IRM-45 family offers 5V at 8A and 40W, 12V at 3.8A and 45.6W, 15V at 3A and 45W, 24V at 1.9A and 45.6W, and 48V at 0.94A and 45.12W. This version is the 24V, 1.9A PCB mounting model, while IRM-45-24ST keeps the same electrical rating with screw terminal style.
Can the IRM-45-24 be used in outdoor or temperature-variable locations?
Its operating temperature is specified from -30°C to +85°C, with load derating at higher temperatures, so the range is broad for enclosed applications. The provided specs do not state an IP rating, so outdoor or weather-exposed use cannot be confirmed from these specifications.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other IRM-45 Models
9 other modelsPlease log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.