Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well HLP-80H-48 PCB Power Supply 80W 48V 1.7A

CV+CCoutput voltage/current level adjustable3-in-1 dimmingclass 2
SKU HLP-80H-48
$49.32 USD
Shipping calculated at checkout.
Available to order
|

Overview

HLP-80H-48 is the 48V output model of this series: rated current 1.7A, rated power 81.6W, typical efficiency 90%.

Features

  • Universal AC input / Full range (up to 305VAC)
  • Built-in active PFC function
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • Output constant current level adjustable
  • Class 2 power unit
  • Three in one dimming function (1~10Vdc or PWM signal or resistance)
  • Suitable for built in LED lighting system
  • Suitable for dry / damp locations
  • 100% full load burn-in test
  • 3 years warranty

Specifications

HLP-80H-48Specifications from the official datasheet (2026-02-09 edition)

OUTPUT

DC VOLTAGE
48V
CONSTANT CURRENT REGIONNote.4
28.8 ~ 48V
RATED CURRENT
1.7A
RATED POWER
81.6W
RIPPLE & NOISE (max.)Note.2
200mVp-p
VOLTAGE ADJ. RANGE
43 ~ 53V
CURRENT ADJ. RANGE
Can be adjusted by internal potentiometer
CURRENT ADJ. RANGE
1.36 ~ 1.7A
VOLTAGE TOLERANCENote.3
±1.0%
LINE REGULATION
±0.5%
LOAD REGULATION
±0.5%
SETUP, RISE TIMENote.6
1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
HOLD UP TIME (Typ.)
16ms at full load 230VAC /115VAC

INPUT

VOLTAGE RANGENote.5
90 ~ 305VAC 127 ~ 431VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
TOTAL HARMONIC DISTORTION
THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
EFFICIENCY (Typ.)
90%
AC CURRENT (Typ.)
0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
INRUSH CURRENT(Typ.)
COLD START 70A(twidth=525μs measured at 50% Ipeak) at 230VAC
MAX. No. of PSUs on 16A CIRCUIT BREAKER
3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
LEAKAGE CURRENT
<0.75mA / 277VAC

PROTECTION

OVER CURRENTNote.4
95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
SHORT CIRCUIT
Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
54 ~ 63V
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.
-40 ~ +70℃(Refer to "Derating Curve")
WORKING HUMIDITY
20 ~ 95% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +80℃, 10 ~ 95% RH
TEMP. COEFFICIENT
±0.03%/℃ (0 ~ 50℃)
VIBRATION
10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes

SAFETY & EMC

SAFETY STANDARDS
UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), BS EN/EN61347-1, BS EN/EN61347-2-13, EAC TP TC 004 approved ; Design refer to UL60950-1
WITHSTAND VOLTAGE
I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE
I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load, 12V model ≧65% load) ; BS EN/EN61000-3-3, EAC TP TC 020
EMC IMMUNITY
Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), criteria B, EAC TP TC 020

OTHERS

MTBF
2786.8K hrs min. Telcordia SR-332(Bellcore) ; 316.2K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
167*53*29.5mm (L*W*H)
PACKING
0.27Kg; 36pcs/11.2Kg/0.67CUFT
Test conditions and notes11
  1. 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
  2. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
  3. 3. Tolerance : includes set up tolerance, line regulation and load regulation.
  4. 4. Please refer to "DRIVING METHODS OF LED MODULE".
  5. 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
  6. 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
  7. 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
  8. 8. Heat Sink HS1,HS2 can not be shorted.
  9. 9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
  10. 10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
  11. 12. This product is not suitable for LED lighting applications in China.

Technical drawings

HLP-80H-48 Mechanical Specification
Mechanical Specification
HLP-80H-48 Block Diagram
Block Diagram
HLP-80H-48 Derating Curve
Derating Curve
HLP-80H-48 Power Factor Characteristic
Power Factor Characteristic
HLP-80H-48 EFFICIENCY vs LOAD (48V Model)
EFFICIENCY vs LOAD (48V Model)
HLP-80H-48 Illustration (page 4)
Illustration (page 4)
HLP-80H-48 Illustration (page 4)
Illustration (page 4)

Downloads

FAQ

What is the output rating of the Mean Well HLP-80H-48?

The HLP-80H-48 is an 80W class open frame AC-DC power supply with a 48V DC output. Its rated output current is 1.7A, making it suitable for applications that require regulated 48V power within that power range.

What kinds of applications is the HLP-80H-48 designed for?

This model is intended for built-in LED lighting systems and other equipment that needs a compact 48V open frame power supply. Its 3-in-1 dimming, adjustable output current, and open frame form factor make it relevant for enclosed OEM and commercial lighting designs.

What input voltage range does the HLP-80H-48 support?

The HLP-80H-48 accepts a universal AC input range of 90-305VAC and also supports 127-431VDC input. That wide range helps it fit projects that need flexibility across different mains power environments.

Can the HLP-80H-48 be used in demanding temperature conditions?

Yes. This power supply is rated for operation from -40°C to +70°C, with derating at higher temperatures as noted in the product data. Working humidity is specified as 20-95% RH non-condensing.

What protection features are included in the HLP-80H-48?

The HLP-80H-48 includes short circuit, over current, over voltage, and over temperature protection. Depending on the fault type, it uses automatic recovery or requires re-powering after the fault condition is removed.

What makes the HLP-80H-48 different from a basic fixed-output power supply?

Compared with simpler fixed-output units, this model includes active power factor correction, 3-in-1 dimming, and an adjustable output current range of 1.36-1.7A. The datasheet also identifies it as an LED power supply meant to operate in its constant current region, which can matter for commercial product selection.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":9873768939840, "variants" :[{ "context":"default", "variant_id": 50917383733568, "sku":"HLP-80H-48", "inventory_qty" : 0, "customer" :true, "custom_html" :"\u003cdiv class=\"price\"\u003e\n \u003cdiv class=\"price__default\"\u003e\n \u003cstrong class=\"price__current\"\u003e$49.32\u003c\/strong\u003e\n \u003cs class=\"price__was\"\u003e\u003c\/s\u003e\n \u003c\/div\u003e\n\n \u003cdiv class=\"unit-price relative\" hidden\u003e\u003cspan class=\"visually-hidden\"\u003eUnit price\u003c\/span\u003e\u003cspan class=\"unit-price__price\"\u003e\u003c\/span\u003e\u003cspan class=\"unit-price__separator\"\u003e \/ \u003c\/span\u003e\u003cspan class=\"unit-price__unit\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv class=\"price__no-variant\" hidden\u003e\n \u003cstrong class=\"price__current\"\u003eUnavailable\u003c\/strong\u003e\n \u003c\/div\u003e\n\n \u003c\/div\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well HLP-80H-48 PCB Power Supply 80W 48V 1.7A
Mean Well

Mean Well HLP-80H-48 PCB Power Supply 80W 48V 1.7A

$49.32 USD

HLP-80H-48 is the 48V output model of this series: rated current 1.7A, rated power 81.6W, typical efficiency 90%.

Features

  • Universal AC input / Full range (up to 305VAC)
  • Built-in active PFC function
  • Protections: Short circuit / Over current / Over voltage / Over temperature
  • Cooling by free air convection
  • Output constant current level adjustable
  • Class 2 power unit
  • Three in one dimming function (1~10Vdc or PWM signal or resistance)
  • Suitable for built in LED lighting system
  • Suitable for dry / damp locations
  • 100% full load burn-in test
  • 3 years warranty
View product