Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLP-80H-30 is the 30V output model of this series: rated current 2.7A, rated power 81W, typical efficiency 90%.
Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- Output constant current level adjustable
- Class 2 power unit
- Three in one dimming function (1~10Vdc or PWM signal or resistance)
- Suitable for built in LED lighting system
- Suitable for dry / damp locations
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 30V
- CONSTANT CURRENT REGIONNote.4
- 18 ~ 30V
- RATED CURRENT
- 2.7A
- RATED POWER
- 81W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGE
- 27 ~ 33V
- CURRENT ADJ. RANGE
- Can be adjusted by internal potentiometer
- CURRENT ADJ. RANGE
- 2.16 ~ 2.7A
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIMENote.6
- 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
- HOLD UP TIME (Typ.)
- 16ms at full load 230VAC /115VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
- EFFICIENCY (Typ.)
- 90%
- AC CURRENT (Typ.)
- 0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 70A(twidth=525μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 35 ~ 43V
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃(Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), BS EN/EN61347-1, BS EN/EN61347-2-13, EAC TP TC 004 approved ; Design refer to UL60950-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load, 12V model ≧65% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), criteria B, EAC TP TC 020
OTHERS
- MTBF
- 2786.8K hrs min. Telcordia SR-332(Bellcore) ; 316.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 167*53*29.5mm (L*W*H)
- PACKING
- 0.27Kg; 36pcs/11.2Kg/0.67CUFT
Test conditions and notes11
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. Heat Sink HS1,HS2 can not be shorted.
- 9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
- 10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 12. This product is not suitable for LED lighting applications in China.
Technical drawings
Downloads
Datasheet1
Certificates4
Catalogues1
Other files1
FAQ
What are the main electrical ratings of the Mean Well HLP-80H-30?
The HLP-80H-30 is an 80W open-frame AC/DC power supply with a 30V output and 2.7A rated current. Its input range is 90-305VAC or 127-431VDC, which supports universal AC input use.
What types of applications is the HLP-80H-30 designed for?
This model is described as suitable for built-in LED lighting systems. Its 30V output, 3-in-1 dimming, and open-frame PCB format make it relevant for OEM and commercial equipment designs that need a compact internal power supply rather than a finished external adapter.
Can the HLP-80H-30 be used in dry or damp locations?
Mean Well does not list a dry or damp location rating for this model; it specifies a working humidity of 20-95% RH non-condensing. It is also rated for operation from -40°C to +70°C, subject to the manufacturer's derating guidance.
What protections are built into the HLP-80H-30?
This model includes short circuit, over current, over voltage, and over temperature protection. The description also notes automatic recovery after some fault conditions are removed, while over-voltage and over-temperature protection require re-powering to recover.
What distinguishes the HLP-80H-30 from a standard fixed-output PCB power supply?
The HLP-80H-30 combines universal 90-305VAC input, active PFC, 3-in-1 dimming, and a specification aimed at LED lighting use. The product description also notes adjustable constant current level capability, which makes it more application-specific than a basic general-purpose internal PSU.
What size is the HLP-80H-30 and why does that matter for equipment design?
The listed dimensions are 167 x 53 x 29.5 mm, and the weight is 0.27 kg. For OEMs and panel builders, that helps determine whether the unit will fit inside compact housings or lighting assemblies where internal clearance is limited.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HLP-80H Models
8 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HLP-80H-54 PCB Power Supply 80W 54V 1.5A | 81W | 54V | 1.5A | View |
| Mean Well HLP-80H-48 PCB Power Supply 80W 48V 1.7A | 81.6W | 48V | 1.7A | View |
| Mean Well HLP-80H-42 PCB Power Supply 80W 42V 1.95A | 81.9W | 48V | 1.95A | View |
| Mean Well HLP-80H-36 PCB Power Supply 80W 36V 2.3A | 82.8W | 36V | 2.3A | View |
| Mean Well HLP-80H-24 PCB Power Supply 80W 24V 3.4A | 81.6W | 24V | 3.4A | View |
| Mean Well HLP-80H-20 PCB Power Supply 80W 20V 4A | 80W | 20V | 4A | View |
| Mean Well HLP-80H-15 PCB Power Supply 75W 15V 5A | 75W | 15V | 5A | View |
| Mean Well HLP-80H-12 PCB Power Supply 60W 12V 5A | 60W | 12V | 5A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.







