Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
HLP-80H-12 is the 12V output model of this series: rated current 5A, rated power 60W, typical efficiency 87.5%.
Features
- Universal AC input / Full range (up to 305VAC)
- Built-in active PFC function
- Protections: Short circuit / Over current / Over voltage / Over temperature
- Cooling by free air convection
- Output constant current level adjustable
- Class 2 power unit
- Three in one dimming function (1~10Vdc or PWM signal or resistance)
- Suitable for built in LED lighting system
- Suitable for dry / damp locations
- 100% full load burn-in test
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 12V
- CONSTANT CURRENT REGIONNote.4
- 7.2 ~12V
- RATED CURRENT
- 5A
- RATED POWER
- 60W
- RIPPLE & NOISE (max.)Note.2
- 150mVp-p
- VOLTAGE ADJ. RANGE
- 10.8 ~ 13.5V
- CURRENT ADJ. RANGE
- Can be adjusted by internal potentiometer
- CURRENT ADJ. RANGE
- 4 ~ 5A
- VOLTAGE TOLERANCENote.3
- ±2.5%
- LINE REGULATION
- ±0.5%
- LOAD REGULATION
- ±2.0%
- SETUP, RISE TIMENote.6
- 1200ms,200ms/115VAC 500ms,200ms/230VAC at 95% load
- HOLD UP TIME (Typ.)
- 16ms at full load 230VAC /115VAC
INPUT
- VOLTAGE RANGENote.5
- 90 ~ 305VAC 127 ~ 431VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF>0.96/115VAC, PF>0.96/230VAC, PF>0.94/277VAC at full load (Please refer to "Power Factor Characteristic" curve)
- TOTAL HARMONIC DISTORTION
- THD< 20% when output loading≧60% at 115VAC/230VAC input and output loading≧75% at 277VAC input
- EFFICIENCY (Typ.)
- 87.5%
- AC CURRENT (Typ.)
- 0.85A / 115VAC 0.425A / 230VAC 0.4A / 277VAC
- INRUSH CURRENT(Typ.)
- COLD START 70A(twidth=525μs measured at 50% Ipeak) at 230VAC
- MAX. No. of PSUs on 16A CIRCUIT BREAKER
- 3 units (circuit breaker of type B) / 5 units (circuit breaker of type C) at 230VAC
- LEAKAGE CURRENT
- <0.75mA / 277VAC
PROTECTION
- OVER CURRENTNote.4
- 95 ~ 108% Protection type : Constant current limiting, recovers automatically after fault condition is removed
- SHORT CIRCUIT
- Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 14 ~ 17V
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -40 ~ +70℃(Refer to "Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +80℃, 10 ~ 95% RH
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 2G 12min./1cycle, period for 72min. each along X, Y, Z axes
SAFETY & EMC
- SAFETY STANDARDS
- UL8750, CSA C22.2 No. 250.0-08 (except for 48V, 54V), BS EN/EN61347-1, BS EN/EN61347-2-13, EAC TP TC 004 approved ; Design refer to UL60950-1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:0.5KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG, O/P-FG:100M Ohms / 500VDC / 25℃/ 70% RH
- EMC EMISSION
- Compliance to BS EN/EN55015, BS EN/EN61000-3-2 Class C (≧60% load, 12V model ≧65% load) ; BS EN/EN61000-3-3, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11, BS EN/EN61547, BS EN/EN55024, light industry level (surge 4KV), criteria B, EAC TP TC 020
OTHERS
- MTBF
- 2786.8K hrs min. Telcordia SR-332(Bellcore) ; 316.2K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 167*53*29.5mm (L*W*H)
- PACKING
- 0.27Kg; 36pcs/11.2Kg/0.67CUFT
Test conditions and notes11
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance : includes set up tolerance, line regulation and load regulation.
- 4. Please refer to "DRIVING METHODS OF LED MODULE".
- 5. Derating may be needed under low input voltages. Please check the static characteristics for more details.
- 6. Length of set up time is measured at cold first start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 7. The power supply is considered a component which will be installed into a final equipment. All the EMC tests are been executed by mounting the unit on a 360mm*360mm metal plate with 1mm of thickness. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to "EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 8. Heat Sink HS1,HS2 can not be shorted.
- 9. Direct connecting to LEDs is suggested, but is not suitable for using additional drivers.
- 10. To fulfill requirements of the latest ErP regulation for lighting fixtures, this LED power supply can only be used behind a switch without permanently connected to the mains.
- 12. This product is not suitable for LED lighting applications in China.
Technical drawings
Downloads
Datasheet1
Certificates4
Catalogues1
Other files1
FAQ
What are the main output specifications of the Mean Well HLP-80H-12?
The HLP-80H-12 is a 12V open-frame AC/DC power supply rated for 60W total output power. Its rated output current is 5A, making it suitable for applications that need a regulated 12V DC supply within that power range.
What kinds of applications is the HLP-80H-12 designed for?
This model is intended for built-in LED lighting systems and other equipment that needs a compact PCB-style AC/DC power supply. Its open-frame format and 3-in-1 dimming make it a fit for OEM and embedded commercial or industrial designs where a 12V, 60W supply is required.
Can the HLP-80H-12 be used in challenging temperature conditions?
Yes. The specified operating temperature range is -40°C to +70°C, which supports use in demanding indoor equipment environments when the application stays within the product's derating limits. Working humidity is specified as 20-95% RH non-condensing.
What protection features are included in the Mean Well HLP-80H-12?
The HLP-80H-12 includes short circuit, over current, over voltage, and over temperature protection. According to the specification, short circuit protection uses hiccup mode with automatic recovery after the fault is removed, while over current protection uses constant-current limiting with automatic recovery.
What input range does the HLP-80H-12 support?
This power supply accepts a universal AC input range of 90 to 305VAC, and it also lists a 127 to 431VDC input range. That wide input capability helps it fit designs intended for global mains environments without needing multiple regional variants.
How does the HLP-80H-12 compare with a sealed power supply?
The HLP-80H-12 is an open-frame PCB power supply, so it is aimed at built-in equipment designs rather than standalone enclosed use. Compared with a sealed power supply, it prioritizes compact integration into OEM assemblies while still offering active PFC, 3-in-1 dimming, and standard protection features.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other HLP-80H Models
8 other models| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well HLP-80H-54 PCB Power Supply 80W 54V 1.5A | 81W | 54V | 1.5A | View |
| Mean Well HLP-80H-48 PCB Power Supply 80W 48V 1.7A | 81.6W | 48V | 1.7A | View |
| Mean Well HLP-80H-42 PCB Power Supply 80W 42V 1.95A | 81.9W | 48V | 1.95A | View |
| Mean Well HLP-80H-36 PCB Power Supply 80W 36V 2.3A | 82.8W | 36V | 2.3A | View |
| Mean Well HLP-80H-30 PCB Power Supply 80W 30V 2.7A | 81W | 30V | 2.7A | View |
| Mean Well HLP-80H-24 PCB Power Supply 80W 24V 3.4A | 81.6W | 24V | 3.4A | View |
| Mean Well HLP-80H-20 PCB Power Supply 80W 20V 4A | 80W | 20V | 4A | View |
| Mean Well HLP-80H-15 PCB Power Supply 75W 15V 5A | 75W | 15V | 5A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.