Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
GSM60A12-P1J is the 12V output model of this series: rated current 5A, typical efficiency 88%.
GSM60A is a highly reliable, 60W desktop style single-output green medical adaptor series.This product is a class I power unit(with FG),equipped with a standard IEC320-C14 AC inlet and adopting the input range from 80VAC to 264VAC. The entire series supplies different models with output voltages between 5VDC and 48VDC that can satisfy the demands for various types of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra low leakage current (<100 μA), fitting the medical devices in direct electrical contact with the patients. With the efficiency up to 91% and the extremely low no-load power consumption below 0.15W,GSM60A is compliant with USA EISA 2007/DoE ,Canada NRCan,Australia and New Zealand MEPS ,EU ErP,and meet Code of Conduct(CoC) Version 5.The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case.GSM60A is certified for the international medical safety regulations.
Features
- 3 pole AC inlet IEC320-C14, ClassⅠpower unit
- Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1 and IEC/BS EN/EN60601-1
- Extremely low leakage current
- No load power consumption<0.15W
- Energy efficiency level VI and meet CoC Version 5 (Except 5~9V for Level V)
- -30~+70℃ wide range working temperature
- Protections: Short circuit / Overload / Over voltage/ Over temperature
- LED indicator for power on
- Lifetime> 105 K hours
- Various DC plug quick adapter accessory available (Plug kit sold sperately,please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
- 3 years warranty
Specifications
OUTPUT
- SAFETY MODEL NO.
- GSM60A12
- DC VOLTAGENote.2
- 12V
- RATED CURRENT
- 5A
- CURRENT RANGE
- 0.1 ~ 5A
- RATED POWER (max.)
- 60W
- RIPPLE & NOISE (max.)Note.3
- 100mVp-p
- VOLTAGE TOLERANCENote.4
- ±3.0%
- LINE REGULATIONNote.5
- ±1.0%
- LOAD REGULATION
- ±3.0%
- SETUP, RISE TIMENote.6
- 1000ms, 30ms / 230VAC 1500ms, 30ms / 115VAC at full load
- HOLD UP TIME (Typ.)
- 50ms / 230VAC 18ms / 115VAC at full load
INPUT
- VOLTAGE RANGENote.7
- 80 ~ 264VAC
- FREQUENCY RANGE
- 47 ~ 63Hz
- EFFICIENCY (Typ.)
- 88%
- AC CURRENT (Typ.)
- 1.4A / 115VAC 1A / 230VAC
- INRUSH CURRENT (Typ.)
- Cold start 30A/115VAC 60A / 230VAC
- LEAKAGE CURRENT(max.)
- Earth leakage current < 100μA/264VAC , Touch current < 100μA/264VAC
PROTECTION
- OVERLOAD
- 105 ~ 160% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 12.6 ~ 16.2V Protection type : Shut down o/p voltage, re-power on to recover
- OVER TEMPERATURE
- Shut down o/p voltage, re-power on to recover
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃ (Refer to "Derating Curve")
- WORKING HUMIDITY
- 20% ~ 90% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03% / ℃ (0~40℃ )
- VIBRATION
- 10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
- OPERATING ALTITUDENote.8
- 3000 meters
SAFETY & EMC (Note 9)
- SAFETY STANDARDS
- IEC 60601-1:2005+A1+A2, TUV BS EN/ EN 60601-1:2006+A1+A12+A2, ANSI/AAMI ES60601-1:2005+A2, CAN/CSA C22.2 No. 60601-1:2014+A2, EAC TP TC 004 approved
- ISOLATION LEVEL
- Primary-Secondary: 2xMOPP, Primary-Earth:1xMOPP
- WITHSTAND VOLTAGE
- I/P-O/P:4KVAC I/P-FG:2KVAC O/P-FG:SHORT
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG:100M Ohms / 500VDC / 25℃ / 70% RH
- EMC EMISSION
-
Parameter Standard Test Level Conducted emission BS EN/EN55011 (CISPR11), J55032(H29)(Only for 12V), FCC PART 15 / CISPR22 Class B Radiated emission BS EN/EN55011 (CISPR11), J55032(H29)(Only for 12V), FCC PART 15 / CISPR22 Class B Harmonic current BS EN/EN61000-3-2 Class A Voltage flicker BS EN/EN61000-3-3 - EMC IMMUNITY
-
BS EN/EN60601-1-2, BS EN/EN61204-3
Parameter Standard Test Level ESD BS EN/EN61000-4-2 Level 4, 15KV air; Level 4, 8KV contact RF field susceptibility BS EN/EN61000-4-3 Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz ) EFT bursts BS EN/EN61000-4-4 Level 3, 2KV Surge susceptibility BS EN/EN61000-4-5 Level 3, 1KV/Line-Line , 2KV/Line-FG Conducted susceptibility BS EN/EN61000-4-6 Level 3, 10V Magnetic field immunity BS EN/EN61000-4-8 Level 4, 30A/m Voltage dip, interruption BS EN/EN61000-4-11 100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods
OTHERS
- MTBF
- 3597.9K hrs min. Telcordia SR-332 (Bellcore) ; 721.1K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 125*50*31.5mm (L*W*H)
- PACKING
- 0.25Kg; 40pcs/ 12Kg/1.04CUFT
CONNECTOR
- PLUG
- See page 4~5 ; Other type available by customer requested
- CABLE
- See page 4~5 ; Other type available by customer requested
Test conditions and notes9
- 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
- 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
- 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μF & 47μF capacitor.
- 4. Tolerance: includes set up tolerance, line regulation, load regulation.
- 5. Line regulation is measured from low line to high line at rated load.
- 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
- 7. Derating may be needed under low input voltages. Pleas check the derating curve for more details.
- 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
- 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )
Technical drawings
Typical applications
- Mobile clinical workstation
- Oral irrigator
- Portable hemodialysis machine
- Breath Machine
- Medical computer monitor
Downloads
Datasheet1
Certificates6
FAQ
What are the main output specifications of the Mean Well GSM60A12-P1J?
This model is a 60W AC/DC power supply with a 12V DC output and a rated current of 5A. It is designed as an external medical adaptor. The standard DC plug is the P1J type, specified as 2.1ø x 5.5ø x 11mm.
Is the GSM60A12-P1J suitable for medical applications?
Yes, this model is medical safety approved and is specified with 2 x MOPP isolation between primary and secondary. The listed safety approvals include IEC 60601-1, ANSI/AAMI ES60601-1, TUV BS EN/EN 60601-1 and CAN/CSA C22.2 No. 60601-1. Its low earth leakage and touch current of less than 100uA also supports medical-use requirements.
What input voltage range does the GSM60A12-P1J support?
The GSM60A12-P1J has a universal input range of 80 to 264VAC at 47 to 63Hz. This full-range input makes it suitable for use across different mains power environments. It is built with an IEC320-C14 AC inlet.
What protection features are included in this power supply?
This model includes protection against overload, over voltage, and over temperature. The overload protection is specified at 105% to 160% of rated output power and operates in hiccup mode with auto-recovery. These protections help safeguard the power supply during abnormal operating conditions.
Can the GSM60A12-P1J be used in demanding temperature environments?
The published working temperature range is -30 to +70°C, with reference to the output derating curve. Working humidity is rated at 20% to 90% RH non-condensing. Buyers should evaluate the application against the stated working-temperature specification and derating curve.
How efficient is the Mean Well GSM60A12-P1J?
This model is specified with a typical efficiency of 88%, measured at 230VAC input and rated load. This characteristic makes it a solid option where energy efficiency matters.
What are the physical size and warranty for the GSM60A12-P1J?
The housing dimensions are 125 x 50 x 31.5 mm, and the listed weight is 0.25 kg. The unit includes a power LED indicator. The spec sheet does not state a warranty period for this model.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Other GSM60 Models
1 other model| Model | Power | Voltage | Current | |
|---|---|---|---|---|
| Mean Well GSM60B18-P1J Power Supply 60W 18V 3.33A | 60W | 18V | 3.33A | View |
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.