Over 15 years experience of providing support of MEAN WELL Power Supplies

Image shown is a representation only. Exact specifications should be obtained from the product datasheet.

Mean Well GSM160B15-R7B Power Supply 144W 15V 9.6A

SKU GSM160B15-R7B
$72.46 USD
Shipping calculated at checkout.
Model

Select model — 15 in this family

GSM160B15-R7B
In stock
|

Overview

GSM160B15-R7B is the 15V output model of this series: rated current 9.6A, typical efficiency 91%.

GSM160B is a highly reliable, 160W desktop style single-output green medical adaptor series. This product is equipped with a 2-pin (no FG) standard IEC320-C8 power plug, adopting the input range from 80VAC to 264VAC. The entire series supplies different output voltages between 12VDC and 48VDC that can satisfy the demands for various kinds of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra low leakage current (<100 μA), fitting the medical devices in direct electrical contact with the patients. With the efficiency up to 94% and the extremely low no-load power consumption below 0.15W, GSM160B is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP,and meet Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GSM160B is approved with the international medical safety certificates.

Features

  • 2 pole AC inlet IEC320-C8, Class Ⅱ power unit
  • Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1/-1-11 and IEC/BS EN/EN60601-1/-1-11
  • Extremely low leakage current
  • No load power consumption<0.15W
  • Energy efficiency level VI and meet CoC Version 5
  • -30~+70℃ wide range working temperature
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • LED indicator for power on
  • Lifetime> 110 K hours
  • Various DC plug quick adapter accessory available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
  • 3 years warranty

Specifications

GSM160B15-R7BSpecifications from the official datasheet (2026-05-09 edition)

OUTPUT

SAFETY MODEL NO.
GSM160B15
DC VOLTAGENote.2
15V
RATED CURRENT
9.6A
CURRENT RANGE
0 ~ 9.6A
RATED POWER (max.)
144W
RIPPLE & NOISE (max.)Note.3
100mVp-p
VOLTAGE TOLERANCENote.4
±5.0%
LINE REGULATIONNote.5
±1.0%
LOAD REGULATION
±5.0%
SETUP, RISE TIMENote.6
2000ms, 50ms / 230VAC 2500ms, 50ms / 115VAC at full load
HOLD UP TIME (Typ.)
24ms / 230VAC 24ms / 115VAC at full load

INPUT

VOLTAGE RANGENote.7
80 ~ 264VAC 113 ~ 370VDC
FREQUENCY RANGE
47 ~ 63Hz
POWER FACTOR (Typ.)
12V/15V:PF>0.93 / 230VAC 20V,24V,48V:PF>0.94 / 230VAC PF>0.98 / 115VAC at full load
EFFICIENCY (Typ.)
91%
AC CURRENT (Typ.)
1.85A / 115VAC 1A / 230VAC
INRUSH CURRENT (Typ.)
Cold start 90A / 115VAC 110A / 230VAC
LEAKAGE CURRENT(max.)
Touch current < 100 μA/264VAC

PROTECTION

OVERLOAD
105 ~ 150% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
OVER VOLTAGE
105 ~ 135% rated output voltage Protection type : Shut down o/p voltage, re-power on to recover
OVER TEMPERATURE
Shut down o/p voltage, re-power on to recover

ENVIRONMENT

WORKING TEMP.
-30 ~ +70℃ (Refer to "Derating Curve")
WORKING HUMIDITY
20% ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY
-40 ~ +85℃, 10 ~ 95% RH non-condensing
TEMP. COEFFICIENT
±0.03% / ℃ (0 ~ 40℃)
VIBRATION
10 ~ 500Hz, 2G 10min./1cycle, period for 60min. each along X, Y, Z axes
OPERATING ALTITUDENote.8
3000 meters

SAFETY & EMC (Note. 9)

SAFETY STANDARDS
IEC 60601-1:2005+A1+A2; IEC 60601-1-11:2015+A1,TUV BS EN/ EN 60601-1:2006+A1+A12+A2; BS EN/ EN 60601-1-11:2015+A1 ANSI/AAMI ES60601-1:2005+A2; ANSI/AAMI HA60601-1-11+A1,CAN/CSA C22.2 No. 60601-1:2014+A2; CSA C22.2 NO. 60601-1-11:2015+A1 EAC TP TC 004 approved
ISOLATION LEVEL
Primary-Secondary: 2xMOPP
WITHSTAND VOLTAGE
I/P-O/P: 4KVAC
ISOLATION RESISTANCE
I/P-O/P:100M Ohms / 500VDC / 25℃/ 70% RH
EMC EMISSION
ParameterStandardTest Level
Conducted emissionBS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22Class B
Radiated emissionBS EN/EN55011 (CISPR11), FCC PART 15 / CISPR22Class B
Harmonic currentBS EN/EN61000-3-2Class A
Voltage flickerBS EN/EN61000-3-3
EMC IMMUNITY

BS EN/EN60601-1-2, BS EN/EN61204-3

ParameterStandardTest Level
ESDBS EN/EN61000-4-2Level 4, 15KV air; Level 4, 8KV contact
RF field susceptibilityBS EN/EN61000-4-3Level 3, 10V/m( 80MHz~2.7GHz ) Table 9, 9~28V/m( 385MHz~5.78GHz )
EFT burstsBS EN/EN61000-4-4Level 3, 2KV
Surge susceptibilityBS EN/EN61000-4-5Level 3, 1KV/Line-Line
Conducted susceptibilityBS EN/EN61000-4-6Level 3, 10V
Magnetic field immunityBS EN/EN61000-4-8Level 4, 30A/m
Voltage dip, interruptionBS EN/EN61000-4-11100% dip 1 periods, 30% dip 25 periods, 100% interruptions 250 periods

OTHERS

MTBF
2191.3K hrs min. Telcordia SR-332 (Bellcore) ; 239.1K hrs min. MIL-HDBK-217F (25℃)
DIMENSION
175*72*35mm (L*W*H)
PACKING
0.66Kg; 20pcs/14.2Kg/0.95CUFT

CONNECTOR

PLUG
See page 4~5; Other type available by customer requested
CABLE
See page 4~5; Other type available by customer requested
Test conditions and notes9
  1. 1. All parameters are specified at 230VAC input, rated load, 25℃ 70% RH ambient.
  2. 2. DC voltage: The output voltage set at point measure by plug terminal & 50% load.
  3. 3. Ripple & noise are measured at 20MHz by using a 12" twisted pair terminated with a 0.1μF & 47μF capacitor.
  4. 4. Tolerance: includes set up tolerance, line regulation, load regulation.
  5. 5. Line regulation is measured from low line to high line at rated load.
  6. 6. Length of set up time is measured at first cold start. Turning ON/OFF the power supply may lead to increase of the set up time.
  7. 7. Derating may be needed under low input voltage. Please check the derating curve for more details.
  8. 8. The ambient temperature derating of 3.5℃/1000m with fanless models and of 5℃/1000m with fan models for operating altitude higher than 2000m(6500ft).
  9. 9. The power supply is considered as an independent unit, but the final equipment still need to re-confirm that the whole system complies with the EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies.” (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf )

Technical drawings

GSM160B15-R7B Derating Curve
Derating Curve
GSM160B15-R7B Mechanical Specification
Mechanical Specification
GSM160B15-R7B DC output plug
DC output plug
GSM160B15-R7B ◎ Optional DC plug: (Available in customized cable or…
◎ Optional DC plug: (Available in customized cable or…
GSM160B15-R7B Pin Assignment
Pin Assignment

Typical applications

  • Mobile clinical workstation
  • Oral irrigator
  • Portable hemodialysis machine
  • Breath Machine
  • Medical computer monitor

Downloads

FAQ

Can the GSM160B15-R7B be used for 15V automation and control equipment?

Yes, it is intended for 15V constant-voltage applications and is rated for up to 9.6A and 144W. That makes it suitable for 15V control equipment, automation electronics, and similar systems within that load range.

Is this model appropriate for 15V embedded hardware or industrial electronics?

It can be used where a stable 15V constant-voltage supply is required. The output capacity is 144W total, with a maximum current of 9.6A.

Can I use this 15V supply for measurement devices, industrial displays, or interface modules?

It can fit 15V measurement, display, or interface equipment if the device specification matches a constant-voltage 15V source. The available output is 15V at up to 9.6A.

Does the GSM160B15-R7B make sense for a 15V bench, fixture, or validation setup?

Yes, it can be used in 15V validation rigs and bench fixtures that need a higher-power AC-DC source. It supports 80-264VAC input and provides up to 144W on the output side.

Can this power supply handle cold or hot operating areas, and is it outdoor-rated?

The product is specified for operation from -30°C to +70°C, with output derating at higher ambient temperatures per the derating curve. The listed specifications do not include an IP rating, so outdoor or water-exposed suitability is not established by the provided data.

Payment & Security

Payment methods

  • American Express
  • Apple Pay
  • Bizum
  • Diners Club
  • Discover
  • Google Pay
  • Mastercard
  • MB WAY
  • PayPal
  • Satispay
  • Shop Pay
  • Visa

Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.

{ "id":8655695675712, "variants" :[{ "context":"default", "variant_id": 46624904773952, "sku":"GSM160B15-R7B", "inventory_qty" : 8, "customer" :true, "custom_html" :"\u003cdiv class=\"price\"\u003e\n \u003cdiv class=\"price__default\"\u003e\n \u003cstrong class=\"price__current\"\u003e$72.46\u003c\/strong\u003e\n \u003cs class=\"price__was\"\u003e\u003c\/s\u003e\n \u003c\/div\u003e\n\n \u003cdiv class=\"unit-price relative\" hidden\u003e\u003cspan class=\"visually-hidden\"\u003eUnit price\u003c\/span\u003e\u003cspan class=\"unit-price__price\"\u003e\u003c\/span\u003e\u003cspan class=\"unit-price__separator\"\u003e \/ \u003c\/span\u003e\u003cspan class=\"unit-price__unit\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\n \u003cdiv class=\"price__no-variant\" hidden\u003e\n \u003cstrong class=\"price__current\"\u003eUnavailable\u003c\/strong\u003e\n \u003c\/div\u003e\n\n \u003c\/div\u003e", "volume_html" :"\u003cvolume-pricing class=\"parent-display inside_product_form\" id=\"volume-pricing-main\" \u003e\u003c\/volume-pricing\u003e" } ] }
Mean Well GSM160B15-R7B Power Supply 144W 15V 9.6A
Mean Well

Mean Well GSM160B15-R7B Power Supply 144W 15V 9.6A

$72.46 USD

GSM160B15-R7B is the 15V output model of this series: rated current 9.6A, typical efficiency 91%.

GSM160B is a highly reliable, 160W desktop style single-output green medical adaptor series. This product is equipped with a 2-pin (no FG) standard IEC320-C8 power plug, adopting the input range from 80VAC to 264VAC. The entire series supplies different output voltages between 12VDC and 48VDC that can satisfy the demands for various kinds of medical electrical devices. The circuitry design meets the international medical standards (2*MOPP), having an ultra low leakage current (<100 μA), fitting the medical devices in direct electrical contact with the patients. With the efficiency up to 94% and the extremely low no-load power consumption below 0.15W, GSM160B is compliant with USA EISA 2007/DoE, Canada NRCan, Australia and New Zealand MEPS, EU ErP,and meet Code of Conduct (CoC) Version 5. The supreme feature allows the adaptor to save the energy when it is either under the operating mode or the standby mode. The entire series utilizes the 94V-0 flame retardant plastic case, providing the double insulation that effectively prevents electrical shock. GSM160B is approved with the international medical safety certificates.

Features

  • 2 pole AC inlet IEC320-C8, Class Ⅱ power unit
  • Medical safety approved (2 x MOPP) according to ANSI/AAMI ES60601-1/-1-11 and IEC/BS EN/EN60601-1/-1-11
  • Extremely low leakage current
  • No load power consumption<0.15W
  • Energy efficiency level VI and meet CoC Version 5
  • -30~+70℃ wide range working temperature
  • Protections: Short circuit / Overload / Over voltage / Over temperature
  • LED indicator for power on
  • Lifetime> 110 K hours
  • Various DC plug quick adapter accessory available (Plug kit sold sperately, please refer to : https://www.meanwell.com/upload/pdf/DC_plug.pdf)
  • 3 years warranty

Typical applications

  • Mobile clinical workstation
  • Oral irrigator
  • Portable hemodialysis machine
  • Breath Machine
  • Medical computer monitor

Model

  • 18W 15V 2 Pole
  • 25W 15V 2 Pole
  • 36W 15V 2 Pole
  • 40W 15V 2 Pole
  • 40W 15V 3 Pole
  • 60W 15V 3 Pole
  • 90W 15V 2 Pole
  • 90W 15V 3 Pole
  • 105W 15V 2 Pole
  • 105W 15V 3 Pole
  • 144W 15V 2 Pole
  • 144W 15V 3 Pole
  • 201W 15V 2 Pole
  • 201W 15V 3 Pole
  • 220W 15V 3 Pole
View product