Over 15 years experience of providing support of MEAN WELL Power Supplies
Overview
UHP-500-15 is the 15V output model of this series: rated current 33.4A, rated power 501W, typical efficiency 94%.
UHP-500 series is a 500W single-output slim type power supply with 31mm of low profile design. Adopting the full range 90~264VAC input, the entire series provides an output voltage line of 4.2V, 5V,12V,15V,24V,36V,48Vand 55V.In addition to the high efficiency up to 95%, that the whole series operates from -30℃ ~ 70℃ under air convection without fan. UHP-500 has the complete protection functions and 5G anti-vibration capability;It is complied with the international safety regulations such as TUV BS EN/EN62368-1,BS EN/EN60335-1, UL 62368-1 and GB 4943.1 . UHP-500 series serves as a high performance power supply solution for various industrial applications.
Features
- Slim and Low profile (31mm)
- Fanless design,500W convection
- Withstand 300VAC surge input for 5 seconds
- Built-in active PFC function
- -30~+70℃ working temperature
- Protections: Short circuit / Overload / Over voltage / Over temperature
- DC OK active signal and redundant function(option)
- Operating altitude up to 5000 meter (Note.5)
- LED indicator for power on
- 3 years warranty
Specifications
OUTPUT
- DC VOLTAGE
- 15V
- RATED CURRENT
- 33.4A
- RATED POWER
- 501W
- RIPPLE & NOISE (max.)Note.2
- 200mVp-p
- VOLTAGE ADJ. RANGENote.7
- 14.3~15.8V
- VOLTAGE TOLERANCENote.3
- ±1.0%
- LINE REGULATION
- ±0.3%
- LOAD REGULATION
- ±0.5%
- SETUP, RISE TIME
- 1000ms, 50ms/230VAC; 1000ms,50ms/115VAC at full load;550ms/230VAC for 55V setup time
- HOLD UP TIME (Typ.)
- 12ms/230VAC 12ms/115VAC
INPUT
- VOLTAGE RANGENote.4
- 90 ~ 264VAC 127 ~ 370VDC
- FREQUENCY RANGE
- 47 ~ 63Hz
- POWER FACTOR (Typ.)
- PF≥0.95/230VAC PF≥0.98/115VAC at full load
- EFFICIENCY (Typ.)
- 94%
- AC CURRENT (Typ.)
- 4.85A/115VAC 2.6A/230VAC
- INRUSH CURRENT (Typ.)Note9
- Cold start 30A/115VAC 60A/230VAC
- LEAKAGE CURRENT
- <0.75mA / 240VAC
PROTECTION
- OVERLOAD
- 110~140% rated output power Protection type : Hiccup mode, recovers automatically after fault condition is removed
- OVER VOLTAGE
- 16.5 ~ 19.5V Protection type :Shut down O/P voltage,re-power on to recover
- OVER TEMPERATURE
- Protection type :Shut down O/P voltage, recovers automatically after temperature goes down
FUNCTION
- DC OK SIGNAL(Optional)
- Contact rating(max.):30Vdc/1A resistive load
- REDUNDANT(Optional)
- For parallel connection protection:For parallel applications, when one PSU can not work , the another one will be automatically enabled. This can prevent the system crash, and provide the reliability of system
ENVIRONMENT
- WORKING TEMP.
- -30 ~ +70℃(Refer to “Derating Curve")
- WORKING HUMIDITY
- 20 ~ 95% RH non-condensing
- STORAGE TEMP., HUMIDITY
- -40 ~ +85℃, 10 ~ 95% RH non-condensing
- TEMP. COEFFICIENT
- ±0.03%/℃ (0 ~ 50℃)
- VIBRATION
- 10 ~ 500Hz, 5G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.6)
- SAFETY STANDARDS
- UL 62368-1,TUV BS EN/EN62368-1,BS EN/EN60335-1(Except for 55V), BS EN/EN61558-1,BS EN/EN61558-2-16, GB 4943.1, BSMI CNS15598-1, BIS IS13252(Part1): 2010/IEC 60950-1: 2005(NOTE 11), EAC TP TC 004 approved; Design refer to AS/NZS 61558.1/2.16, AS/NZS 62368.1
- WITHSTAND VOLTAGE
- I/P-O/P:3.75KVAC I/P-FG:2KVAC O/P-FG:1.25KVAC
- ISOLATION RESISTANCE
- I/P-O/P, I/P-FG,O/P-FG:100M Ohms/500VDC/25℃/ 70%RH
- EMC EMISSION
- Compliance to BS EN/EN55032,GB17625.1,GB/T 9254.1,Class B, BS EN/EN61000-3-2,-3, BSMI CNS15936, EAC TP TC 020
- EMC IMMUNITY
- Compliance to BS EN/EN61000-4-2,3,4,5,6,8,11;BS EN/EN61000-6-2 (BS EN/EN50082-2),BS EN/EN55035, heavy industry level ,EAC TP TC 020
OTHERS
- MTBF
- 1264.1 K hrs min. Telcordia SR-332 (Bellcore) ; 167.6K hrs min. MIL-HDBK-217F (25℃)
- DIMENSION
- 232*81*31mm (L*W*H)
- PACKING
- 0.905kg; 16pcs/15.48kg/0.82CUFT
Test conditions and notes11
- 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25℃ of ambient temperature.
- 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
- 3. Tolerance :includes set up tolerance, line regulation and load regulation.
- 4. Derating may be needed under low input voltages. Please check the derating curve for more details.
- 5. The ambient temperature derating of 3.5℃/1000m is needed for operating altitude greater than 2000m(6500ft)
- 6. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. For guidance on how to perform these EMC tests, please refer to “EMI testing of component power supplies." (as available on https://www.meanwell.com//Upload/PDF/EMI_statement_en.pdf)
- 7. Please refer to derating curve.
- 8. R type efficiency slightly less than the Blank type, according to the actual measurement.
- 9. Inrush current parameter has 10% tolerance.
- 10. RCM is on voluntary basis and meets relevant IEC or AS/NZS standards complying with AS/NZS 4417.1.
- 11. Some models or factory may not have the BIS marking , please contact MEAN WELL’s sales for more details.
Technical drawings
Typical applications
- Industrial automation machinery
- Industrial control system
- Mechanical and electrical equipment
- Electronic instruments, equipments or apparatus
- LED display application
- Power Source Equipment for PoE(55V model)
Downloads
Certificates9
Test reports1
FAQ
Can I use the UHP-500-15 for 15V industrial electronics or automation equipment?
Yes, when the equipment is designed for constant voltage 15V input and the load remains within 501W and 33.4A. This makes it a candidate for industrial electronics, embedded systems, and control hardware built around a 15V DC rail.
Is the UHP-500-15 suitable for 15V test benches or lab equipment with a fixed DC bus?
It can be used where the system needs a regulated 15V constant voltage supply up to 33.4A and 501W. The 90-264VAC input range also supports use in facilities with different AC mains standards.
Can this supply support multiple 15V subsystems inside a compact machine or panel?
Yes, if the combined 15V demand stays within 501W and 33.4A. Its 232.0 x 81.0 x 31.0 mm low-profile housing and fanless design are useful when space and airflow are limited.
What is the difference between the UHP-500-15 and the other UHP-500 voltage options?
The listed UHP-500 models are 4.2V 336W 80A, 5V 400W 80A, 12V 500.4W 41.7A, 15V 501W 33.4A, 24V 501.6W 20.9A, 36V 500.4W 13.9A, and 48V 501.6W 10.45A. This model is the 15V version, so it sits between the 12V and 24V options in output voltage while keeping similar overall power class.
Is the UHP-500-15 suitable for outdoor locations or high-temperature indoor use?
The operating temperature range is -30C to +70C, which supports wide-temperature indoor environments. The specs provided do not list an IP rating, so outdoor exposure suitability is not confirmed by the available data.
Payment & Security
Payment methods
Your payment information is processed securely. We do not store credit card details nor have access to your credit card information.
Please log in to write a review.
Write a review
Reviews are checked before publishing. By submitting you confirm this is your genuine experience with this product.
Submitting your review…
It's published and now helps other buyers.
We're checking it and it'll appear shortly.
Please try again.